Stereotaxic core needle aspiration biopsy with multiple passes in nonpalpable breast lesions

被引:0
|
作者
Bolivar, AV [1 ]
García, EO
Ayensa, FG
机构
[1] Hosp Marques de Valdecilla, Dept Radiol, Fac Med, E-39008 Santander, Spain
[2] Hosp Marques de Valdecilla, Dept Pathol, Fac Med, E-39008 Santander, Spain
关键词
breast neoplasms; biopsy; localization;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the grade of histologic agreement between stereotaxic core needle aspiration biopsy (SCNAB) with multiple passes, and surgical excision. Methods: A total of 180 patients with 182 nonpalpable breast lesions underwent SCNAB with multiple passes in an upright add-on stereotaxic device using a manual 1.8-mm needle (15 G). In this group, 125 patients underwent subsequent surgical excision. Results: A SCNAB result indicative of malignancy (invasive or noninvasive carcinoma) was obtained in 68 (87%) of the 78 breast carcinomas (14 noninvasive and 64 invasive) and definitive surgical therapy with a one-stage procedure was performed. Complete or partial agreement between core biopsy and surgery was observed in 19 (86%) of 22 invasive or noninvasive carcinomas discovered by microcalcifications, 40 (97.5%) of 41 invasive carcinomas discovered by a mass, and 9 (60%) of 15 invasive or noninvasive carcinomas discovered by architectural distortion. Six (33%) of the 18 patients whose core biopsies showed noninvasive carcinoma had an invasive or microinvasive component at subsequent surgery. Atypical hyperplasia or benign core biopsy was observed in 6 (8%) and 4 (5%) breast carcinomas respectively. Conclusion: SCNAB with multiple passes is a reliable method for identifying nonpalpable lesions in patients with noninvasive or invasive carcinomas discovered by respectively microcalcifications or mass.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 50 条
  • [41] STEREOTAXIC NEEDLE CORE BIOPSY OF BREAST-LESIONS USING A REGULAR MAMMOGRAPHIC TABLE WITH AN ADAPTABLE STEREOTAXIC DEVICE
    CAINES, JS
    MCPHEE, MD
    KONOK, GP
    WRIGHT, BA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) : 317 - 321
  • [42] THE POTENTIAL VALUE OF MAMMOGRAPHICALLY GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS
    MASOOD, S
    FRYKBERG, ER
    MITCHUM, DG
    MCLELLAN, GL
    SCALAPINO, MC
    BULLARD, JB
    AMERICAN SURGEON, 1989, 55 (04) : 226 - 231
  • [43] OUTPATIENT NEEDLE LOCALIZATION AND BIOPSY FOR NONPALPABLE BREAST-LESIONS
    HOMER, MJ
    SMITH, TJ
    MARCHANT, DJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 252 (17): : 2452 - 2454
  • [44] NEEDLE LOCALIZATION AND FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS WITH USE OF STANDARD AND STEREOTACTIC EQUIPMENT
    EVANS, WP
    CADE, SH
    RADIOLOGY, 1989, 173 (01) : 53 - 56
  • [45] POST-LOCALIZATION NEEDLE FOR BREAST BIOPSY OF NONPALPABLE LESIONS
    HOMER, MJ
    FISHER, DM
    SUGARMAN, HJ
    RADIOLOGY, 1981, 140 (01) : 241 - 242
  • [46] NONPALPABLE BREAST-TUMORS - DIAGNOSIS WITH STEREOTAXIC LOCALIZATION AND FINE-NEEDLE ASPIRATION
    DOWLATSHAHI, K
    GENT, HJ
    SCHMIDT, R
    JOKICH, PM
    BIBBO, M
    SPRENGER, E
    RADIOLOGY, 1989, 170 (02) : 427 - 433
  • [47] PROSPECTIVE EVALUATION OF RADIOLOGICALLY DIRECTED FINE-NEEDLE ASPIRATION BIOPSY OF NONPALPABLE BREAST-LESIONS
    MASOOD, S
    FRYKBERG, ER
    MCLELLAN, GL
    SCALAPINO, MC
    MITCHUM, DG
    BULLARD, JB
    CANCER, 1990, 66 (07) : 1480 - 1487
  • [49] Stereotactic core needle biopsy of nonpalpable breast lesions - Initial experience with a promising technique - Discussion
    Deckers, PJ
    Sutton, J
    Quinlan, RM
    Colacchio, T
    Seoudi, H
    ARCHIVES OF SURGERY, 1998, 133 (04) : 371 - 372
  • [50] Intraoperative ultrasonographically guided excisional biopsy or vacuum-assisted core needle biopsy for nonpalpable breast lesions
    Chen, SC
    Yang, HR
    Hwang, TL
    Chen, MF
    Cheung, YC
    Hsueh, S
    ANNALS OF SURGERY, 2003, 238 (05) : 738 - 742