Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review

被引:12
|
作者
Wang, Hongwei [1 ,2 ]
Zhao, Yiwen [2 ]
Mo, Zhongjun [3 ]
Han, Jianda [2 ]
Chen, Yu [1 ]
Yu, Hailong [1 ]
Wang, Qi [1 ]
Liu, Jun [1 ]
Li, Changqing [4 ]
Zhou, Yue [2 ]
Xiang, Liangbi [1 ]
机构
[1] Gen Hosp Shenyang Mil Area Command Chinese PLA, Dept Orthoped, Shenyang, Liaoning, Peoples R China
[2] Chinese Acad Sci, Shenyang Inst Automat, State Key Lab Robot, Shenyang 110016, Liaoning, Peoples R China
[3] Natl Res Ctr Rehabil Aids, Beijing 100176, Peoples R China
[4] Third Mil Med Univ, Xinqiao Hosp, Dept Orthoped, Chongqing 400037, Peoples R China
关键词
Biomechanics; Finite Element Analysis; Spine Fracture; Monoaxial Pedicle Screw; Polyaxial Pedicle Screw; LUMBAR INTERBODY FUSION; BURST FRACTURES; DISC DEGENERATION; ADJACENT; INSTRUMENTATION; SPINE; LEVEL; EFFICACY; DISEASE; STRESS;
D O I
10.6061/clinics/2017(10)04
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb's angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb's angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group.
引用
收藏
页码:609 / 617
页数:9
相关论文
共 50 条
  • [31] Comparison of unilateral versus bilateral pedicle screw fixation at the level of fracture using posterior short-segment pedicle instrumentation in the treatment of severe thoracolumbar burst fractures
    Sun, Chao
    Liu, Xinhui
    Tian, Jiwei
    Guan, Guoping
    Zhang, Hailong
    INTERNATIONAL JOURNAL OF SURGERY, 2017, 41 : 50 - 55
  • [32] Restoration of Anterior Vertebral Height by Short-Segment Pedicle Screw Fixation with Screwing of Fractured Vertebra for the Treatment of Unstable Thoracolumbar Fractures
    Ozdemir, Bulent
    Kanat, Ayhan
    Erturk, Cihangir
    Batcik, Osman Ersagun
    Balik, Mehmet Sabri
    Yazar, Ugur
    Celiker, Fatma Beyazal
    Metin, Yavuz
    Inecikli, Mehmet Fatih
    Guvercin, Ali Riza
    WORLD NEUROSURGERY, 2017, 99 : 409 - 417
  • [33] Comparison of Polyaxial or Poly/Monoaxial Mixed Screw Fixation for Treatment of Thoracolumbar Fractures with O -Arm Navigation: A Case-Control Study
    Qin, Wanjin
    Chen, Kangwu
    Chen, Hao
    Yang, Peng
    Yang, Huilin
    Mao, Haiqing
    WORLD NEUROSURGERY, 2020, 138 : E10 - E16
  • [34] Comparison of short-segment pedicle fixation with versus without inclusion of the fracture level in the treatment of mild thoracolumbar burst fractures
    Sun, Chao
    Guan, Guoping
    Liu, Xinhui
    Zhang, Hailong
    Wang, Bin
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 36 : 352 - 357
  • [35] Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: a computational biomechanics analysis
    Elmasry, Shady
    Asfour, Shihab
    Travascio, Francesco
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (13) : 1412 - 1420
  • [36] Effect of the short-segment internal fixation with intermediate inclined-angle polyaxial screw at the fractured vertebra on the treatment of Denis type B thoracolumbar fracture
    Xiong, Chengjie
    Huang, Biwang
    Wei, Tanjun
    Kang, Hui
    Xu, Feng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [37] Effect of the short-segment internal fixation with intermediate inclined-angle polyaxial screw at the fractured vertebra on the treatment of Denis type B thoracolumbar fracture
    Chengjie Xiong
    Biwang Huang
    Tanjun Wei
    Hui Kang
    Feng Xu
    Journal of Orthopaedic Surgery and Research, 15
  • [38] Intermediate screws or kyphoplasty: Which method of posterior short-segment fixation is better for treating single-level thoracolumbar burst fractures?
    Zhang, Junxin
    Liu, Hao
    Liu, Hui
    Chen, Angela Carley
    He, Fan
    Zhou, Feng
    Yang, Huilin
    Liu, Tao
    EUROPEAN SPINE JOURNAL, 2019, 28 (03) : 502 - 510
  • [39] Intermediate screws or kyphoplasty: Which method of posterior short-segment fixation is better for treating single-level thoracolumbar burst fractures?
    Junxin Zhang
    Hao Liu
    Hui Liu
    Angela Carley Chen
    Fan He
    Feng Zhou
    Huilin Yang
    Tao Liu
    European Spine Journal, 2019, 28 : 502 - 510
  • [40] Long versus short segment with intermediate screw fixation for burst fractures of thoracolumbar junction: radiological and clinical results
    Rispoli, Rossella
    Abousayed, Mahmoud
    Hamed, Alaa A.
    Cappelletto, Barbara
    JOURNAL OF NEUROSURGICAL SCIENCES, 2024, 68 (05) : 567 - 573