Hyperelastic parameter identification of human articular cartilage and substitute materials

被引:16
|
作者
Weizel, A. [1 ]
Distler, T. [2 ]
Detsch, R. [2 ]
Boccaccini, A. R. [2 ]
Braeuer, L. [3 ]
Paulsen, F. [3 ]
Seitz, H. [1 ,4 ]
Budday, S. [5 ]
机构
[1] Univ Rostock, Fac Mech Engn & Marine Technol, Chair Microfluid, D-18059 Rostock, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Inst Biomat, Dept Mat Sci & Engn, D-91058 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg, Inst Funct & Clin Anat, D-91054 Erlangen, Germany
[4] Univ Rostock, Dept Life Light & Matter, D-18059 Rostock, Germany
[5] Friedrich Alexander Univ Erlangen Nurnberg, Inst Appl Mech, Dept Mech Engn, D-91058 Erlangen, Germany
关键词
Parameter identification; Finite hyperelasticity; Human articular cartilage; Hydrogels; Tissue engineering; MECHANICAL-BEHAVIOR; MODELS; STRAIN; RUBBER; DEFORMATION; ELASTICITY; HYDROGELS;
D O I
10.1016/j.jmbbm.2022.105292
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Numerical simulations are a valuable tool in the field of tissue engineering for cartilage repair and can help to understand which mechanical properties affect the behavior of chondrocytes and contribute to the success or failure of surrogate materials as implants. However, special attention needs to be paid when identifying corresponding material parameters in order to provide reliable numerical predictions of the material's response. In this study, we identify hyperelastic material parameters for numerical simulations in COMSOL Multiphysics (R) v. 5.6 for human articular cartilage and two surrogate materials, commercially available ChondroFiller(liquid), and oxidized alginate-gelatin (ADA-GEL) hydrogels. We consider several hyperelastic isotropic material models and provide separate parameter sets for the unconditioned and the conditioned material response, respectively, based on previously generated experimental data including both compression and tension experiments. We compare a direct parameter identification approach assuming homogeneous deformation throughout the specimen and an inverse approach, where the experiments are simulated using a finite element model with realistic boundary conditions in COMSOL Multiphysics (R) v. 5.6. We demonstrate that it is important to consider both compression and tension data simultaneously and to use the inverse approach to obtain reliable parameters. The one-term Ogden model best represents the unconditioned response of cartilage, while the conditioned response of cartilage and ADA-GEL is equally well represented by the two-term Ogden and five-term Mooney-Rivlin models. The five-term Mooney-Rivlin model is also most suitable to model the unconditioned response of ADA-GEL. For ChondroFiller(liquid), we suggest using the five-term Mooney-Rivlin or two-term Ogden model for the unconditioned and the two-term Ogden model for the conditioned material response. These results will help to choose appropriate material models and parameters for simulations of whole joints or to advance mechanical-stimulation assisted cartilage tissue engineering in the future.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Time-dependent hyper-viscoelastic parameter identification of human articular cartilage and substitute materials
    Weizel, A.
    Distler, T.
    Detsch, R.
    Boccaccini, A. R.
    Seitz, H.
    Budday, S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 138
  • [2] Adaptivity for parameter identification of incompressible hyperelastic materials using stabilized tetrahedral elements
    Widany, Kai-Uwe
    Mahnken, Rolf
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2012, 245 : 117 - 131
  • [3] A Modified Constitutive Model for Isotropic Hyperelastic Polymeric Materials and Its Parameter Identification
    Wang, Wei
    Liu, Yang
    Xie, Zongwu
    POLYMERS, 2023, 15 (15)
  • [4] Hyperelastic constitutive modeling of healthy and enzymatically mediated degraded articular cartilage
    Istiak, Asif
    Islam, Saiful
    Adouni, Malek
    Faisal, Tanvir R.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2025,
  • [5] Tribological characterization of polyvinyl alcohol hydrogel as substitute of articular cartilage
    Sardinha, V. M.
    Lima, L. L.
    Belangero, W. D.
    Zavaglia, C. A.
    Bavaresco, V. P.
    Gomes, J. R.
    WEAR, 2013, 301 (1-2) : 218 - 225
  • [6] Inverse Parameter Identification for Hyperelastic Model of a Polyurea
    Xiao, Yihua
    Tang, Ziqiang
    Hong, Xiangfu
    POLYMERS, 2021, 13 (14)
  • [7] Progenitor cells isolated from human articular cartilage: identification and characterisation
    Williams, R.
    Khan, I. M.
    Richardson, K.
    Nelson, L.
    Baird, D. M.
    Roberts, S.
    Briggs, T.
    Fairclough, J.
    Archer, C. W.
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2011, 92 (06) : A15 - A15
  • [8] Modeling of articular cartilage replacement materials
    Stoffel, M.
    Weichert, D.
    Rath, R. Mueller
    ARCHIVES OF MECHANICS, 2009, 61 (01): : 69 - 87
  • [9] Identification of mesenchymal progenitor cells in normal and osteoarthritic human articular cartilage
    Alsalameh, S
    Amin, R
    Gemba, T
    Lotz, M
    ARTHRITIS AND RHEUMATISM, 2004, 50 (05): : 1522 - 1532
  • [10] REGIONAL HYPERELASTIC PROPERTIES OF HUMAN HIP CARTILAGE
    Henak, Corinne R.
    Weiss, Jeffrey A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 733 - 734