A high sensitivity time-resolved microfluorimeter for real-time cell biology

被引:8
|
作者
MartinFernandez, ML
Tobin, MJ
Clarke, DT
Gregory, CM
Jones, GR
机构
[1] CCLRC Daresbury Laboratory
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 10期
关键词
D O I
10.1063/1.1147138
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe an instrument based on the novel combination of synchrotron radiation, a high sensitivity time-resolved microfluorimeter, and a multiframe single photon counting data acquisition system. This instrument has been designed specifically to measure kinetic events in live cells using fluorescence resonance energy transfer, and is capable of rapidly collecting multiple consecutive decay profiles from a small number of fluorophores. The low irradiance on the samples (< 10 mW/cm(2)) greatly reduces probe photobleaching and specimen photodamage during prolonged exposures. The Daresbury Synchrotron Radiation Source provides fully wavelength tunable light pulses that have a full width half-maximum of 160 ps at a repetition rate of 3.125 MHz, with the high temporal stability required for continuous measurements over periods of hours. A very low limit of detection (< 10(4) molecules/mW/cm(2)) is accomplished by combining a high-gain single photon counting detection system with a low fluorescence background optical layout. The latter is achieved by the inclusion of collimating optics, a reflecting objective, and a specially designed beam stop situated in the epi-fluorescence light-path. A typical irradiance of 8 mW/cm(2) on a sample of similar to 10(5) fluorescein molecules gives, in under 20 a, a fluorescence decay profile with a peak height of 10(4) counts, over 400 channels, and a signal to background ratio better than 40. The data acquisition system has been developed to have a real-time time-resolved fluorescence collection capability (denoted as TR(2)) so that fluorescence lifetime data can be continually collected throughout a changing process. To illustrate the potential of this instrument, we present the results of a TR(2) experiment in which lifetime measurements of fluorescence resonance energy transfer are used to monitor the degree of clustering of epidermal growth factor receptors during endocytosis, over a period of about 1 h, with a 5 s resolution. (C) 1996 American Institute of Physics.
引用
收藏
页码:3716 / 3721
页数:6
相关论文
共 50 条
  • [41] Development of a Real-Time Gamma Dosimeter of High Sensitivity
    Sharma, S. L.
    Maity, T. K.
    Kumar, G. Anil
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 341 - +
  • [42] Tracking Insulin Glycation in Real Time by Time-Resolved Emission Spectroscopy
    Chung, Li Hung C.
    Birch, David J. S.
    Vyshemirsky, Vladislav
    Ryadnov, Maxim G.
    Rolinski, Olaf J.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2019, 123 (37): : 7812 - 7817
  • [43] Peptide Vectors Carry Pyrene to Cell Organelles Allowing Real-Time Quantification of Free Radicals in Mitochondria by Time-Resolved Fluorescence Microscopy
    Wawi, Mohamad Jamal
    Bijoux, Amandine
    Inguimbert, Nicolas
    Mahler, Christoph
    Wagner, Stephan
    Marder, Todd B.
    Ribou, Anne-Cecile
    CHEMBIOCHEM, 2021, 22 (09) : 1676 - 1685
  • [44] Real-Time Probing of the Synthesis of Colloidal Silver Nanocubes with Time-Resolved High-Energy Synchrotron X-ray Diffraction
    Peng, Sheng
    Okasinski, John S.
    Almer, Jonathan D.
    Ren, Yang
    Wang, Lin
    Yang, Wenge
    Sun, Yugang
    JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (21): : 11842 - 11847
  • [45] Characterization of a Time-Resolved, Real-Time Scintillation Dosimetry System for Ultra-High Dose-Rate Radiation Therapy Applications
    Baikalov, Alexander
    Tho, Daline
    Liu, Kevin
    Bartzsch, Stefan
    Beddar, Sam
    Schuler, Emil
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 121 (05): : 1372 - 1383
  • [46] High-sensitivity detection of PSA by time-resolved fluorometry with europium chelate
    Nahm, KB
    Jeong, JH
    Kim, BC
    Kim, JH
    Kim, YM
    Jeong, DS
    Oh, SW
    Choi, EY
    Ko, DS
    ICO20: BIOMEDICAL OPTICS, 2006, 6026
  • [47] THE DEVELOPMENT OF HIGH-SENSITIVITY PULSED-LIGHT, TIME-RESOLVED FLUOROIMMUNOASSAYS
    EKINS, RP
    DAKUBU, S
    PURE AND APPLIED CHEMISTRY, 1985, 57 (03) : 473 - 482
  • [48] A high-sensitivity femtosecond to microsecond time-resolved infrared vibrational spectrometer
    Towrie, M
    Gabrielsson, A
    Matousek, P
    Parker, AW
    Rodriguez, AMB
    Vlcek, A
    APPLIED SPECTROSCOPY, 2005, 59 (04) : 467 - 473
  • [49] A new red phosphor for high time-resolved thermal sensitivity and plant growth
    Bi, Yu-Xi
    Zhao, Dan
    Zhang, Rui-Juan
    Yao, Qing-Xia
    DALTON TRANSACTIONS, 2024, 53 (45) : 18237 - 18242
  • [50] Improvement in time-resolved fluoroimmunoassay sensitivity for carbofuran.
    Bacigalupo, MA
    Meroni, G