Harmonization of PET image reconstruction parameters in simultaneous PET/MRI

被引:3
|
作者
Laforest, Richard [1 ]
Khalighi, Mehdi [2 ]
Natsuaki, Yutaka [3 ]
Rajagopal, Abhejit [4 ]
Chandramohan, Dharshan [4 ]
Byrd, Darrin [5 ]
An, Hongyu [1 ]
Larson, Peder [4 ]
St James, Sara [3 ]
Sunderland, John J. [5 ]
Kinahan, Paul E. [6 ]
Hope, Thomas A. [4 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[4] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[5] Univ Iowa, Iowa City, IA USA
[6] Univ Washington, Seattle, WA 98195 USA
关键词
Image reconstruction; Harmonization; PET; MRI; Phantom; WHOLE-BODY PET/MR; PERFORMANCE-MEASUREMENTS; FDG PET/CT; NOISE; MAXIMUM; PHANTOM;
D O I
10.1186/s40658-021-00416-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Simultaneous PET/MRIs vary in their quantitative PET performance due to inherent differences in the physical systems and differences in the image reconstruction implementation. This variability in quantitative accuracy confounds the ability to meaningfully combine and compare data across scanners. In this work, we define image reconstruction parameters that lead to comparable contrast recovery curves across simultaneous PET/MRI systems. Method The NEMA NU-2 image quality phantom was imaged on one GE Signa and on one Siemens mMR PET/MRI scanner. The phantom was imaged at 9.7:1 contrast with standard spheres (diameter 10, 13, 17, 22, 28, 37 mm) and with custom spheres (diameter: 8.5, 11.5, 15, 25, 32.5, 44 mm) using a standardized methodology. Analysis was performed on a 30 min listmode data acquisition and on 6 realizations of 5 min from the listmode data. Images were reconstructed with the manufacturer provided iterative image reconstruction algorithms with and without point spread function (PSF) modeling. For both scanners, a post-reconstruction Gaussian filter of 3-7 mm in steps of 1 mm was applied. Attenuation correction was provided from a scaled computed tomography (CT) image of the phantom registered to the MR-based attenuation images and verified to align on the non-attenuation corrected PET images. For each of these image reconstruction parameter sets, contrast recovery coefficients (CRCs) were determined for the SUVmean, SUVmax and SUVpeak for each sphere. A hybrid metric combining the root-mean-squared discrepancy (RMSD) and the absolute CRC values was used to simultaneously optimize for best match in CRC between the two scanners while simultaneously weighting toward higher resolution reconstructions. The image reconstruction parameter set was identified as the best candidate reconstruction for each vendor for harmonized PET image reconstruction. Results The range of clinically relevant image reconstruction parameters demonstrated widely different quantitative performance across cameras. The best match of CRC curves was obtained at the lowest RMSD values with: for CRCmean, 2 iterations-7 mm filter on the GE Signa and 4 iterations-6 mm filter on the Siemens mMR, for CRCmax, 4 iterations-6 mm filter on the GE Signa, 4 iterations-5 mm filter on the Siemens mMR and for CRCpeak, 4 iterations-7 mm filter with PSF on the GE Signa and 4 iterations-7 mm filter on the Siemens mMR. Over all reconstructions, the RMSD between CRCs was 1.8%, 3.6% and 2.9% for CRC mean, max and peak, respectively. The solution of 2 iterations-3 mm on the GE Signa and 4 iterations-3 mm on Siemens mMR, both with PSF, led to simultaneous harmonization and with high CRC and low RMSD for CRC mean, max and peak with RMSD values of 2.8%, 5.8% and 3.2%, respectively. Conclusions For two commercially available PET/MRI scanners, user-selectable parameters that control iterative updates, image smoothing and PSF modeling provide a range of contrast recovery curves that allow harmonization in harmonization strategies of optimal match in CRC or high CRC values. This work demonstrates that nearly identical CRC curves can be obtained on different commercially available scanners by selecting appropriate image reconstruction parameters.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data
    Loeb, Rebekka
    Navab, Nassir
    Ziegler, Sibylle I.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) : 2233 - 2247
  • [42] Commercially Competitive Vendor-Agnostic Image Reconstruction Could Be a Leap Forward for PET Harmonization
    Kesner, Adam L.
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (02) : 323 - 324
  • [43] Simultaneous reconstruction of attenuation and activity in ToF PET/MRI with additional transmission data
    Ester D’Hoe
    Pieter Mollet
    Ekaterina Mikhaylova
    Michel Defrise
    Stefaan Vandenberghe
    EJNMMI Physics, 2 (Suppl 1)
  • [44] Using time-of-flight information for PET, PET/CT and PET/MRI reconstruction
    Nuyts, Johan
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2020, 43 (01):
  • [45] Quantitative, Simultaneous PET/MRI for Intratumoral Imaging with an MRI-Compatible PET Scanner
    Ng, Thomas S. C.
    Bading, James R.
    Park, Ryan
    Sohi, Hargun
    Procissi, Daniel
    Colcher, David
    Conti, Peter S.
    Cherry, Simon R.
    Raubitschek, Andrew A.
    Jacobs, Russell E.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (07) : 1102 - 1109
  • [46] Masamune: a tool for automatic dynamic PET data processing, image reconstruction and integrated PET/MRI data analysis
    Daniel B Chonde
    David Izquierdo-Garcia
    Kevin Chen
    Spencer L Bowen
    Ciprian Catana
    EJNMMI Physics, 1 (Suppl 1)
  • [47] An AI system to determine reconstruction parameters and improve PET image quality
    Gao, Fei
    Shah, Vijay
    Sibille, Ludovic
    Zuehlsdorff, Sven
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [48] Effect of PET Image Reconstruction Parameters on Quantitative Treatment Response Assessment
    Morrison, C.
    Vanderhoek, M.
    Perlman, S.
    Jeraj, R.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [49] Improvements in PET Image quality from TOF PET/MRI
    Minamimoto, R.
    Jamali, M.
    Barkhodari, A.
    Holley, D.
    Zaharchuk, G.
    Levin, C.
    Iagaru, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S19 - S19
  • [50] Impact of PET reconstruction parameters on the quantitation of longitudinal PET Aβ-amyloid
    Ruwanpathirana, G.
    Williams, R.
    Masters, C.
    Rowe, C.
    Davey, C.
    Johnston, L.
    INTERNAL MEDICINE JOURNAL, 2022, 52 : 43 - 44