Harmonization of PET image reconstruction parameters in simultaneous PET/MRI

被引:3
|
作者
Laforest, Richard [1 ]
Khalighi, Mehdi [2 ]
Natsuaki, Yutaka [3 ]
Rajagopal, Abhejit [4 ]
Chandramohan, Dharshan [4 ]
Byrd, Darrin [5 ]
An, Hongyu [1 ]
Larson, Peder [4 ]
St James, Sara [3 ]
Sunderland, John J. [5 ]
Kinahan, Paul E. [6 ]
Hope, Thomas A. [4 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA USA
[4] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[5] Univ Iowa, Iowa City, IA USA
[6] Univ Washington, Seattle, WA 98195 USA
关键词
Image reconstruction; Harmonization; PET; MRI; Phantom; WHOLE-BODY PET/MR; PERFORMANCE-MEASUREMENTS; FDG PET/CT; NOISE; MAXIMUM; PHANTOM;
D O I
10.1186/s40658-021-00416-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Simultaneous PET/MRIs vary in their quantitative PET performance due to inherent differences in the physical systems and differences in the image reconstruction implementation. This variability in quantitative accuracy confounds the ability to meaningfully combine and compare data across scanners. In this work, we define image reconstruction parameters that lead to comparable contrast recovery curves across simultaneous PET/MRI systems. Method The NEMA NU-2 image quality phantom was imaged on one GE Signa and on one Siemens mMR PET/MRI scanner. The phantom was imaged at 9.7:1 contrast with standard spheres (diameter 10, 13, 17, 22, 28, 37 mm) and with custom spheres (diameter: 8.5, 11.5, 15, 25, 32.5, 44 mm) using a standardized methodology. Analysis was performed on a 30 min listmode data acquisition and on 6 realizations of 5 min from the listmode data. Images were reconstructed with the manufacturer provided iterative image reconstruction algorithms with and without point spread function (PSF) modeling. For both scanners, a post-reconstruction Gaussian filter of 3-7 mm in steps of 1 mm was applied. Attenuation correction was provided from a scaled computed tomography (CT) image of the phantom registered to the MR-based attenuation images and verified to align on the non-attenuation corrected PET images. For each of these image reconstruction parameter sets, contrast recovery coefficients (CRCs) were determined for the SUVmean, SUVmax and SUVpeak for each sphere. A hybrid metric combining the root-mean-squared discrepancy (RMSD) and the absolute CRC values was used to simultaneously optimize for best match in CRC between the two scanners while simultaneously weighting toward higher resolution reconstructions. The image reconstruction parameter set was identified as the best candidate reconstruction for each vendor for harmonized PET image reconstruction. Results The range of clinically relevant image reconstruction parameters demonstrated widely different quantitative performance across cameras. The best match of CRC curves was obtained at the lowest RMSD values with: for CRCmean, 2 iterations-7 mm filter on the GE Signa and 4 iterations-6 mm filter on the Siemens mMR, for CRCmax, 4 iterations-6 mm filter on the GE Signa, 4 iterations-5 mm filter on the Siemens mMR and for CRCpeak, 4 iterations-7 mm filter with PSF on the GE Signa and 4 iterations-7 mm filter on the Siemens mMR. Over all reconstructions, the RMSD between CRCs was 1.8%, 3.6% and 2.9% for CRC mean, max and peak, respectively. The solution of 2 iterations-3 mm on the GE Signa and 4 iterations-3 mm on Siemens mMR, both with PSF, led to simultaneous harmonization and with high CRC and low RMSD for CRC mean, max and peak with RMSD values of 2.8%, 5.8% and 3.2%, respectively. Conclusions For two commercially available PET/MRI scanners, user-selectable parameters that control iterative updates, image smoothing and PSF modeling provide a range of contrast recovery curves that allow harmonization in harmonization strategies of optimal match in CRC or high CRC values. This work demonstrates that nearly identical CRC curves can be obtained on different commercially available scanners by selecting appropriate image reconstruction parameters.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Harmonization of PET image reconstruction parameters in simultaneous PET/MRI
    Richard Laforest
    Mehdi Khalighi
    Yutaka Natsuaki
    Abhejit Rajagopal
    Dharshan Chandramohan
    Darrin Byrd
    Hongyu An
    Peder Larson
    Sara St. James
    John J. Sunderland
    Paul E. Kinahan
    Thomas A. Hope
    EJNMMI Physics, 8
  • [2] Harmonization of PET Image Reconstruction Parameters on Multiple PET/MRI System
    Laforest, Richard
    Khalighi, Mohammad Mehdi
    Byrd, Darrin
    An Hongyu
    Larson, Peder
    Sunderland, John
    Kinahan, Paul
    Hope, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [3] Harmonization of reconstruction parameters bewteen PET/MR (SIGNA) and PET/CT (Discovery STE)
    Hurtado de Mendoza, A.
    Mosconi, S.
    Marino, E.
    Alberti, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S73 - S74
  • [4] PET Image Quality Improvement for Simultaneous PET/MRI with a Lightweight MRI Surface Coil
    Deller, Timothy W.
    Mathew, Nicholas K.
    Hurley, Samuel A.
    Bobb, Chad M.
    McMillan, Alan B.
    RADIOLOGY, 2021, 298 (01) : 166 - 172
  • [5] Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI
    Ryogo Minamimoto
    Craig Levin
    Mehran Jamali
    Dawn Holley
    Amir Barkhodari
    Greg Zaharchuk
    Andrei Iagaru
    Molecular Imaging and Biology, 2016, 18 : 776 - 781
  • [6] Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI
    Minamimoto, Ryogo
    Levin, Craig
    Jamali, Mehran
    Holley, Dawn
    Barkhodari, Amir
    Zaharchuk, Greg
    Iagaru, Andrei
    MOLECULAR IMAGING AND BIOLOGY, 2016, 18 (05) : 776 - 781
  • [7] MRI-Guided Motion-Corrected PET Image Reconstruction for Cardiac PET/MRI
    Munoz, Camila
    Ellis, Sam
    Nekolla, Stephan G.
    Kunze, Karl P.
    Vitadello, Teresa
    Neji, Radhouene
    Botnar, Rene M.
    Schnabel, Julia A.
    Reader, Andrew J.
    Prieto, Claudia
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (12) : 1768 - 1774
  • [8] Simultaneous maximum a posteriori longitudinal PET image reconstruction
    Ellis, Sam
    Reader, Andrew J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 6963 - 6979
  • [9] MRI Guided Myocardial Perfusion PET Image Reconstruction
    Tang, Jing
    Wang, Xinhui
    Karakatsanis, Nicolas A.
    Lu, Lijun
    Rahmim, Arman
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [10] Investigation of acquisition time for harmonization of image quality between PET/CT and PET/MRI systems: A phantom study
    Yoon, Seok Hwan
    Park, Chan Rok
    OPTIK, 2021, 244