Oxidation Stability of Insulating Liquids by Rapid Small Scale Oxidation Test

被引:0
|
作者
Cruze, Ann Pamla [1 ]
Lokesh, K. S. [2 ]
Prakash, R. R. Siva [1 ]
机构
[1] Cent Power Res Inst, Dielect Mat Div, Bengaluru, India
[2] JSS Sci & Technol Univ, Environm Engn, Mysore, Karnataka, India
来源
2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL) | 2019年
关键词
Insulating liquids; Oxidation stability; Induction period; Rapid small scale test method;
D O I
10.1109/icdl.2019.8796702
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Insulation materials are an important component of transformers; the life of the electrical equipment depends on the quality of solid and liquid insulating materials used. Mineral insulating oils, synthetic esters and natural esters are different types of liquid insulating materials. During prolonged service in electrical apparatus these oils undergo deterioration, mainly due to continuous oxidation. Hence, the long-term performance of insulating oils depends on the stability to oxidation. This behaviour is usually termed as resistance to the oxidation process or oxidation stability. Oxidation stability test as per test method IEC 61125 and ASTM D2112 are familiar methods to test the oils. According to IEC 61125 (Method C) the insulating oil, is conditioned at 120 degrees C, with copper catalyst and by bubbling zero air over a duration of 48 hours for natural esters, 164 hours for uninhibited oils and synthetic esters, 500 hours for Inhibited oils. Rotating Pressure Vessel Oxidation Test method (RPVOT) as per ASTM D2112 requires copper catalyst and oxygen pressure of 620 kpa is allowed to oxidize the oil sample at 140 degrees C. Zero air bubbling method assesses the oil based on measurement of dissipation factor, acidity and and sludge development for mineral oil and synthetic esters and dissipation factor, acidity and viscosity for natural esters. RPVOT method measures the induction period. Although the IEC 61125 is conventional, it is time consuming and the RPVOT curve for natural esters cannot be distinguished due to the poor stability characteristics of natural esters. This paper presents the results carried out to measure oxidation stability by using a new method named as Rapid Small Scale Oxidation Test (RSSOT) as per ASTM D7545, using petroxy equipment to measure the induction period. Oxidation stability test has been carried out on mineral insulating oils, synthetic esters and natural esters. The results are compared to assess the suitability of the rapid small scale method for evaluating the stability of insulation oils. It is found that the rapid small scale method is suitable to measure the oxidation stability and the results are comparable to the conventional methods. Further, natural ester and synthetic ester was analyzed both with copper catalyst and without catalyst. It was found that presence of copper catalyst accelerates the rate of oxidation of both synthetic ester and natural ester. RSSOT has the advantage of being a rapid method, simple and easy to use, and where only a small quantity of sample is needed, thereby reducing the risks to safety and waste sample disposal problems.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Investigating the Impact of Phenolic Antioxidants on the Oxidation Stability of Synthetic Ester Insulating Oil
    Zhang, Ying
    Wang, Feipeng
    Li, Jian
    Xu, Yang
    Qian, Yihua
    Rozga, Pawel
    Pompili, Massimo
    Scatiggio, Fabio
    Campi, Giorgi
    Ren, Yibo
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [22] BUBBLES IN INSULATING LIQUIDS - STABILITY IN ELECTRIC FIELD
    GARTON, CG
    KRASUCKI, Z
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1964, 280 (1380) : 211 - +
  • [23] RAPID SMALL-SCALE TEST FOR WHEAT HARDNESS
    MORRISON, P
    JOURNAL OF FLOUR AND ANIMAL FEED MILLING, 1977, 160 (02): : 23 - 23
  • [24] A new type of mixed vegetable insulating oil with better kinematic viscosity and oxidation stability
    Chen, Binghao
    Su, Ziming
    Du, Zhenbin
    Ma, Mingyuan
    Zhang, Junjie
    Tang, Chao
    JOURNAL OF MOLECULAR LIQUIDS, 2022, 360
  • [25] Contributions on Increasing Safety in Exploitation of Power Transformers by Checking the Stability to Oxidation of the Insulating Oil
    Cujba, Tiberiu-Octavian
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 432 - 435
  • [26] PLASMA OXIDATION OF LIQUIDS.
    Suhr, H.
    Schmid, H.
    Pfeundschuh, H.
    Iacocca, D.
    1600, (04):
  • [27] Internal oxidation with simultanious external scale formation: Front stability
    Mchedlov-Petrossyan, PO
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2002, 24 (01): : 25 - 34
  • [28] Improvement of the standard dielectric breakdown test for insulating liquids
    Lick, W.
    Pukel, G. J.
    Muhr, H. M.
    Baur, M.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 208 - +
  • [29] As(III) oxidation during full-scale aeration and rapid filtration
    Gude, J. C. J.
    Rietveld, L. C.
    van Halem, D.
    ENVIRONMENTAL ARSENIC IN A CHANGING WORLD (AS2018), 2018, : 447 - 448
  • [30] ELECTROHYDRODYNAMIC STABILITY OF INSULATING LIQUIDS SUBMITTED TO UNIPOLAR INJECTION
    ATTEN, P
    MOREAU, R
    JOURNAL DE MECANIQUE, 1972, 11 (03): : 471 - &