Electrokinetic injection for stacking neutral analytes in capillary and microchip electrophoresis

被引:94
|
作者
Palmer, J
Burgi, DS
Munro, NJ
Landers, JP
机构
[1] Univ Virginia, Dept Chem, Charlottesville, VA 22901 USA
[2] Univ Virginia, Dept Pathol, Charlottesville, VA 22901 USA
[3] Mol Dynam, Sunnyvale, CA 94086 USA
关键词
D O I
10.1021/ac001046d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-column mechanism for electrokinetically injecting long sample plugs with simultaneous stacking of neutral analytes in capillary electrokinetic chromatography is presented. On-column stacking methods allow for the direct injection of long sample plugs into the capillary, with narrowing of the analyte peak width to allow for an increase in the detected signal. Low-pressure injections (similar to 50 mbar) are commonly used to introduce sample plugs containing neutral analytes. We demonstrate that injection can be accomplished by applying an electric field from the sample vial directly into the capillary, with neutral analytes injected by electroosmotic now at up to 1 order of magnitude faster than the corresponding pressure injections, Since stacking occurs simultaneously with electrokinetic injection, stacking is initiated at the capillary inlet, resulting in an increased length of capillary remaining for separation. Reproducibility obtained for peak height and peak area with electroosmotic flow injection is comparable to that obtained with the pressure injection mode, while reproducibility of analysis time is markedly improved. Electrokinetic stacking of neutral analytes utilizing electroosmotic flow is demonstrated with discontinuous (high conductivity, high mobility) as well as continuous (equal conductivity, equal mobility) sample electrolytes, Injecting neutral analytes by electroosmotic now affords a 10-fold or greater decrease. in analysis times when capillaries of 50-mum i.d. or smaller are used. This stacking method should be exportable to dynamic pH junction stacking and electrokinetic chromatography with capillary arrays. Equations describing this electrokinetic injection mode are introduced and stacking of a neutral analyte on a microchip by electrokinetic injection using a simple cross-T channel configuration is demonstrated.
引用
收藏
页码:725 / 731
页数:7
相关论文
共 50 条
  • [21] Electrokinetic stacking of electrically neutral analytes with paper-based analytical device
    Song, Yi-Zhen
    Zhang, Xiu-Xiu
    Liu, Jia-Juan
    Fang, Fang
    Wu, Zhi-Yong
    TALANTA, 2018, 182 : 247 - 252
  • [22] Separation of organomercury species using nonaqueous capillary electrophoresis coupled with sample stacking and electrokinetic injection techniques
    Peng, Zhen-Lei
    Song, Guanqun
    Zhao, Lixia
    Lin, Jin-Ming
    CHROMATOGRAPHIA, 2006, 64 (5-6) : 281 - 285
  • [23] Separation of Organomercury Species Using Nonaqueous Capillary Electrophoresis Coupled with Sample Stacking and Electrokinetic Injection Techniques
    Zhen-Lei Peng
    Guanqun Song
    Lixia Zhao
    Jin-Ming Lin
    Chromatographia, 2006, 64 : 281 - 285
  • [24] MICROCHIP SEPARATIONS OF NEUTRAL SPECIES VIA MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY
    MOORE, AW
    JACOBSON, SC
    RAMSEY, JM
    ANALYTICAL CHEMISTRY, 1995, 67 (22) : 4184 - 4189
  • [25] Three-step stacking of cationic analytes by field-enhanced sample injection, sweeping, and micelle to solvent stacking in capillary electrophoresis
    Grochocki, Wojciech
    Markuszewski, Michal J.
    Quirino, Joselito P.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1424 : 111 - 117
  • [26] Three-step stacking by field-enhanced sample injection, sweeping, and micelle to solvent stacking in capillary electrophoresis: Anionic analytes
    Grochocki, Wojciech
    Markuszewski, Michal J.
    Quirino, Joselito P.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1442 : 140 - 143
  • [27] High-sensitivity capillary and microchip electrophoresis using electrokinetic supercharging preconcentration Insight into the stacking mechanism via computer modeling
    Xu, Zhongqi
    Timerbaev, Andrei R.
    Hirokawa, Takeshi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (04) : 660 - 670
  • [28] MICROCHIP ELECTROPHORESIS WITH SAMPLE STACKING
    JACOBSON, SC
    RAMSEY, JM
    ELECTROPHORESIS, 1995, 16 (04) : 481 - 486
  • [29] Capillary electrophoresis on microchip
    Dolník, V
    Liu, SR
    Jovanovich, S
    ELECTROPHORESIS, 2000, 21 (01) : 41 - 54
  • [30] Capillary and Microchip Electrophoresis
    Kitagawa, Fumihiko
    ANALYTICAL SCIENCES, 2020, 36 (08) : 899 - 900