A Novel Design of a Plate for Posterolateral Tibial Plateau Fractures Through Traditional Anterolateral Approach

被引:15
|
作者
Ren, Dong [1 ]
Liu, Yueju [1 ]
Lu, Jian [1 ]
Xu, Runtao [1 ]
Wang, Pengcheng [1 ]
机构
[1] Hebei Med Univ, Major Lab Orthopaed Biomech Hebei Prov, Hosp 3, Orthopaed Trauma Serv Ctr, Shijiazhuang, Hebei, Peoples R China
来源
SCIENTIFIC REPORTS | 2018年 / 8卷
关键词
OSTEOTOMY;
D O I
10.1038/s41598-018-34818-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Biomechanical performance of a newly designed plate for treating posterolateral tibial plateau fractures was compared with three traditional internal fixation devices using finite element analysis (FEA) and biomechanical experiments. Forty synthetic tibias were used to create posterolateral shearing tibial fracture models, which were randomly assigned to groups A-D. The fragments were fixed with two 6.5-mm lag screws (group A), the newly designed plate (group B), a 3.5-mm lateral locking plate (group C), and a posterolateral buttress plate (group D). In the biomechanical experiment, vertical displacement of the posterolateral fragments was measured under axial loads of 500-1500 N. In the FEA, vertical displacement of the posterolateral fragments and stress distribution and maximum stress of each internal fixation were measured under axial loads of 250-750 N. Biomechanically, collective ranges of vertical displacements in the four groups were 0.356 +/- 0.089-1.055 +/- 0.023 mm at 500 N axial load, 0.651 +/- 0.062-1.525 +/- 0.03 mm at 1000 N, and 0.903 +/- 0.077-1.796 +/- 0.04 mm at 1500 N. Differences between the four groups were statistically significant (P < 0.05), except for groups B and C at 1500 N. FEA showed that collective ranges of vertical displacements in the four groups were 0.290-1.425 mm at of 250 N axial load, 0.580-1.680 mm at 500 N, 1.067-1.818 mm at 750 N. Maximum stress of groups A-D were, respectively, 321.940, 132.660, 100.383, and 321.940 MPa under 250 N axial load. Maximum stress of all four internal fixations increased, and the overall trends at 500 and 750 N were consistent with that at 250 N. Posterior, straight fixation was the most reliable. Fixation with the lag screw was least reliable. The new plate and 3.5-mm lateral locking plate exhibited similar control over fragment displacement. The newly designed plate was stable and reliable, indicating its suitability for clinical application.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Approaches and fixation of the posterolateral fracture fragment in tibial plateau fractures: a review with an emphasis on rim plating via modified anterolateral approach
    Jae-Woo Cho
    Jinil Kim
    Won-Tae Cho
    Jin-Kak Kim
    Puspak Samal
    Pranay H. Gujjar
    William T. Kent
    Jong-Keon Oh
    International Orthopaedics, 2017, 41 : 1887 - 1897
  • [42] RETRACTED ARTICLE: An osteotomy anterolateral approach for lateral tibial plateau fractures merged with relatively simple and intact posterolateral corner displacement
    De-peng Meng
    Tian-wen Ye
    Ai-min Chen
    Journal of Orthopaedic Surgery and Research, 9
  • [43] The study of biomechanics and finite element analysis on a novel plate for tibial plateau fractures via anterolateral supra-fibular-head approach
    Yao Lu
    HuanAn Bai
    Qian Wang
    Cheng Ren
    Ming Li
    Zhong Li
    Kun Zhang
    Qiang Huang
    Teng Ma
    Scientific Reports, 13
  • [44] The study of biomechanics and finite element analysis on a novel plate for tibial plateau fractures via anterolateral supra-fibular-head approach
    Lu, Yao
    Bai, HuanAn
    Wang, Qian
    Ren, Cheng
    Li, Ming
    Li, Zhong
    Zhang, Kun
    Huang, Qiang
    Ma, Teng
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis
    Zhaokui Yan
    Chang Zou
    Guy Romeo Kenmegne
    Xuelin Pan
    Nawin Ghimire
    Kuruwitage Manthi Nihara Silva
    Yue Fang
    Journal of Orthopaedic Surgery and Research, 19
  • [46] Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis
    Yan, Zhaokui
    Zou, Chang
    Kenmegne, Guy Romeo
    Pan, Xuelin
    Ghimire, Nawin
    Silva, Kuruwitage Manthi Nihara
    Fang, Yue
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [47] Posterolateral Approach for Plating of Tibial Plateau Fractures and the Risk of Injury to the Anterior Tibial Vessels In Response
    Heidari, Nima
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (09) : e229 - e229
  • [48] A New Posterolateral Approach Without Fibula Osteotomy for the Treatment of Tibial Plateau Fractures
    Frosch, Karl-Heinz
    Balcarek, Peter
    Walde, Tim
    Stuermer, Klaus Michael
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (08) : 515 - 520
  • [49] The posterolateral approach for plating tibial plateau fractures: problems in secondary hardware removal
    Huang, Yi-Gang
    Chang, Shi-Min
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (05) : 733 - 734
  • [50] Finite element analysis of a novel anatomical plate in posterolateral plateau fractures
    Jian, Zhen
    Jiang, Xinhua
    Li, Dejian
    Zhou, Jianhua
    Yu, Baoqing
    Yi, Chengqing
    FRONTIERS IN SURGERY, 2024, 11