Reliability analysis of structures incorporating shunted piezoelectric transducers for the purpose of passive vibration mitigation

被引:0
|
作者
Cunha, L. R. [1 ]
Saad, N. S. [1 ]
Rade, D. A. [1 ]
机构
[1] Fed Univ Uberlandia UFU, Sch Mech Engn FEMEC, Lab Struct Mech LMEst, BR-38408100 Uberlandia, MG, Brazil
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Among the passive techniques of vibration control, the use of piezoelectric transducers connected to electric circuits has been intensively investigated lately. However, as is the case of any engineering system, uncertainties affecting the physical and geometrical characteristics of the control device are unavoidable and prone to jeopardize the control performance. In this context, this paper is devoted to the numerical procedures intended for the evaluation of the reliability of structures containing shunted piezoelectric transducers. Reliability here is meant as the probability of complying with pre-defined control goals, given the probability distributions ascribed to the uncertain variables, which are modeled as continuous random variables. The performance goals are accounted for by the proper choice of the so-called limit state functions (LSF), which are computed from the structural responses. The reliability indices are computed by using First Order Reliability Method (FORM) and the results are compared to Monte Carlo Simulation (MCS) associated to Latin Hypercube Sampling (LHS). Numerical simulations are presented for a truss structure modeled by finite elements, containing a piezoelectric stack transducer connected to a resistive-inductive (resonant) shunt circuit. The comparison between FORM and MCS results enables to evaluate the accuracy and computational effort involved in the use of both methods.
引用
收藏
页码:4453 / 4466
页数:14
相关论文
共 50 条
  • [31] Shunted piezoelectric patch vibration absorber on two-dimensional thin structures: Tuning considerations
    Gardonio, P.
    Casagrande, D.
    JOURNAL OF SOUND AND VIBRATION, 2017, 395 : 26 - 47
  • [32] Lateral vibration attenuation of a beam with circular cross-section by a support with integrated piezoelectric transducers shunted to negative capacitances
    Goetz, Benedict
    Schaeffner, Maximilian
    Platz, Roland
    Melz, Tobias
    SMART MATERIALS AND STRUCTURES, 2016, 25 (09)
  • [33] OPTIMIZATION OF SHUNTED PIEZOELECTRIC PATCHES FOR VIBRATION REDUCTION OF COMPLEX STRUCTURES - APPLICATION TO A TURBOJET FAN BLADE
    Senechal, Aurelien
    Thomas, Olivier
    Deue, Jean Francois
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, DETC 2010, VOL 5, 2010, : 695 - +
  • [34] On the analysis of passive vibration mitigation of nose landing gears
    Rahmani, M.
    Behdinan, K.
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 43 - 48
  • [35] An efficient FE approach for attenuation of acoustic radiation of thin structures by using passive shunted piezoelectric systems
    Larbi, Walid
    da Silva, Luciano Pereira
    Deu, Jean-Francois
    APPLIED ACOUSTICS, 2017, 128 : 3 - 13
  • [36] Passive low-frequency vibration mitigation in large space structures
    Lowry, Madeline P.
    Willey, Carson L.
    Chen, Vincent W.
    Nouh, Mostafa
    Juhl, Abigail T.
    MRS COMMUNICATIONS, 2024, 14 (05) : 1007 - 1014
  • [37] A UNIFIED ANALYSIS OF BOTH ACTIVE AND PASSIVE DAMPING FOR A PLATE WITH PIEZOELECTRIC TRANSDUCERS
    KOSHIGOE, S
    MURDOCK, JW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (01): : 346 - 355
  • [38] Multimode vibration suppression with passive two-terminal distributed network incorporating piezoceramic transducers
    Batra, RC
    dell'Isola, F
    Vidoli, S
    Vigilante, D
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2005, 42 (11-12) : 3115 - 3132
  • [39] Correction to: Assessment of shunted piezoelectric devices for simultaneous noise and vibration reduction: comparison of passive, active and hybrid networks
    Seyyed M. Hasheminejad
    Mehran Shahraeeni
    Meccanica, 2020, 55 : 289 - 289
  • [40] Multiple PZT transducers implemented with multiple-mode piezoelectric shunting for passive vibration damping
    Wu, SY
    SMART STRUCTURES AND MATERIALS 1999: PASSIVE DAMPING AND ISOLATION, 1999, 3672 : 112 - 122