Direct measurement of X-ray spectrum is a challenging issue because of high photon flux, and the increased Pileup effect, and the dead time. In this study, a Compton spectrometer is constructed and tested for X-ray spectrometry. The spectrometer is composed of a shielded chamber, a scattering rod, and an HPGe semiconductor detector. The spectrum of the X-rays scattered by the scattering rod which was recorded in the HPGe detector, along with the detector response matrix was used for unfolding the primary X-ray photon. The ill-conditioned systems of the equation were solved by the regularization methods based on the single values decomposition. The unfolded X-ray spectra and the HVL were compared with the theoretical spectrum of the IPEM 78 report catalog. The results indicate that the X-ray spectrum may be unfolded using this indirect method with sufficient accuracy. According to the results, Compton spectrometry can be used for spectrum measurement, as a part of the quality control of the X-ray machine.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] COMPTON REFLECTED SPECTRA OF X-RAY ILLUMINATED STELLAR ATMOSPHERES
    FELSTEINER, J
    OPHER, R
    ASTRONOMY & ASTROPHYSICS, 1976, 46 (02) : 189 - 195
  • [22] Compton scattering and the X-ray spectra of accreting compact objects
    Psaltis, D
    Lamb, FK
    ACCRETION PROCESSES IN ASTROPHYSICAL SYSTEMS: SOME LIKE IT HOT!, 1998, (431): : 125 - 128
  • [24] Experimental X-ray tube spectra
    Gorgl, R
    Wobrauschek, P
    Streli, C
    Aiginger, H
    Benedikt, M
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (03): : 589 - 604
  • [25] Direct measurement of clinical mammographic x-ray spectra using a CdTe spectrometer
    Santos, Josilene C.
    Tomal, Alessandra
    Furquim, Tania A.
    Fausto, Agnes M. F.
    Nogueira, Maria S.
    Costa, Paulo R.
    MEDICAL PHYSICS, 2017, 44 (07) : 3504 - 3511
  • [26] New energy spectral measurements of a distributed x-ray source with a Compton spectrometer
    Gehring, A. E.
    Espy, M. A.
    Haines, T. J.
    Richardson, A. S.
    Zier, J. C.
    RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XIX, 2018, 10763
  • [27] Dispersion-compensating scanning X-ray spectrometer for Compton profile measurements
    Suortti, P
    Buslaps, T
    DiMichiel, M
    Honkimäki, V
    Lienert, U
    McCarthy, JE
    Merino, JM
    Shukla, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 (PART II): : 1541 - 1544
  • [28] X-ray spectra transmitted through Compton-thick absorbers
    Matt, G
    Pompilio, F
    La Franca, F
    NEW ASTRONOMY, 1999, 4 (03): : 191 - 195
  • [29] The X-ray spectrometer
    不详
    NATURE, 1915, 94 : 199 - 200
  • [30] AN X-RAY SPECTROMETER USING THERMOLUMINESCENCE DETECTORS
    BAIGARIN, KA
    ZINCHENKO, VF
    LIKHOLAT, VM
    TIMOFEEV, VV
    SOVIET ATOMIC ENERGY, 1991, 70 (06): : 515 - 518