Platelets stored in a new-generation container - Differences between plasma and platelet additive solution II

被引:31
|
作者
de Wildt-Eggen, J
Schrijver, JG
Smid, WM
Joie, M
Bollinne, V
Bins, M
机构
[1] Red Cross Bloodbank IJssellanden, NL-8000 AD Zwolle, Netherlands
[2] Baxter R&D Europe, Nivelles SCRL, Nivelles, Belgium
关键词
D O I
10.1159/000030990
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: In order to preserve platelet concentrates (PCs) with high yields, a new polyolefin platelet storage container (PL 2410, 1.3L, Baxter, La Chatre, France) with increased gas permeability in combination with, a larger surface area has been developed. The storage capacity was studied with platelets in plasma and platelets additive solution. Materials and Methods: Platelet concentrate pools (PCs) of different yields suspended in either plasma (PCs-PL; n = 30) or PAS II (PCs-PAS; n = 37) were prepared. For preparation of PCs with a low, intermediate and high number of platelets 3, 5 and 6 buffy coat. (BCs) were pooled with different volumes of plasma and 5 and 6 BCs were pooled with different volumes of PAS II, in order to obtain PCs of equal volumes comparable with routine conditions. All PCs were stored on a flatbed shaker at 22 +/-2 degrees C and evaluated on days 1, 2, 5 and 7 by determining platelet and white cell counts, pH (37 degrees C), pO(2), pCO(2) and swirling score. Results: Platelet yields ranged from 1.5 up to 5.5 x 10(11) platelets/U. On day 7 all PCs-PL (n = 4) with platelet yields above 4.5 x 10(11)/U had a pH value below 6.8 (range 5.91-6.79). While 7 of 8 PCs-PAS units with platelet yields above 4.0 x 10(11)/U showed a pH value below 6.8 (range 6.31-6.70). Conclusion: During 7 days of storage in a new 1.3-liter platelet container, the pH was maintained above 6.8 in PCs in plasma with a yield. between 1.5- and 4.5 x 10(11)/U; when PAS II was used, the maximum platelet yield allowed for comparable pH maintenance was Somewhat lower (4.0 x 10(11)/U).
引用
收藏
页码:218 / 223
页数:6
相关论文
共 50 条
  • [41] EVALUATION OF A NEW PLATELET (PLT) ADDITIVE SOLUTION FOR STORAGE OF BUFFY COAT (BC) PLATELETS
    FIGUEROA, P
    PINEDA, A
    HALLING, V
    CARMEN, R
    KUBOTA, L
    NELSON, E
    TRANSFUSION, 1993, 33 (09) : S7 - S7
  • [42] Bacterial Detection Testing: Growth in Aerobic Culture Media for Platelets Suspended in the Platelet Additive Solution InterSol® Compared to Platelets in Plasma
    Hapip, C. A.
    Keegan, T. E.
    Liu, B.
    George, G.
    Seetharaman, S.
    Kurtz, J.
    Leiby, D. A.
    TRANSFUSION, 2011, 51 : 57A - 58A
  • [43] Retention of Platelet Concentration Levels During Storage of Apheresis Platelets with 100 Percent Plasma or Additive Solution
    Moroff, G.
    Seetharaman, S.
    Kurtz, J. W.
    Skripchenko, A.
    Wagner, S. J.
    TRANSFUSION, 2010, 50 : 67A - 67A
  • [44] Comparative in vitro evaluation of apheresis platelets stored with 100% plasma or 65% platelet additive solution III/35% plasma and including periods without agitation under simulated shipping conditions
    Moroff, Gary
    Kurtz, James
    Seetharaman, Shalini
    Skripchenko, Andrey
    Awatefe, Helen
    Thompson-Montgomery, Dedeene
    Myrup, Andrew
    Wagner, Stephen J.
    TRANSFUSION, 2012, 52 (04) : 834 - 843
  • [45] Mirasol Treatment of Day 10 Cold-Stored Platelets in Platelet Additive Solution and Its Impact on Platelet Hemostatic Function, Activation, and Mitochondrial Integrity
    Reddoch, Kristin
    Montgomery, Robbie K.
    Taylor, Ashley S.
    Cap, Andrew P.
    TRANSFUSION, 2017, 57 : 21A - 21A
  • [46] Clinical effectiveness of leucoreduced, pooled donor platelet concentrates, stored in plasma or additive solution with and without pathogen reduction
    Kerkhoffs, Jean-Louis H.
    van Putten, Wim L. J.
    Novotny, Viera M. J.
    Boekhorst, Peter A. W. Te
    Schipperus, Martin R.
    Zwaginga, Jaap Jan
    van Pampus, Lizzy C. M.
    de Greef, Georgine E.
    Luten, Marleen
    Huijgens, Peter C.
    Brand, Anneke
    van Rhenen, Dick J.
    BRITISH JOURNAL OF HAEMATOLOGY, 2010, 150 (02) : 209 - 217
  • [47] The new generation of platelet additive solution for storage at 22°C:: Development and current experience
    Ringwald, J
    Zimmermann, R
    Eckstein, R
    TRANSFUSION MEDICINE REVIEWS, 2006, 20 (02) : 158 - 164
  • [48] Storage of platelet concentrates in Composol-PS additive solution in a new citrate-ester PVC container
    Van der Meer, PF
    Pietersz, RN
    Reesink, HW
    TRANSFUSION, 2000, 40 (10) : 62S - 62S
  • [49] Whole blood platelet rich plasma derived pools stored in additive solution preserve good function to 7 days
    Sweeney, JD
    Kouttab, NM
    Cheves, TA
    Kurtis, JD
    Nelson, EJ
    Holme, S
    TRANSFUSION, 2005, 45 (03) : 30A - 31A
  • [50] Differences in short-term outcome between early- and new-generation TAVR devices
    Veulemans, V.
    Klein, K.
    Maier, O.
    Wolff, G.
    Polzin, A.
    Westenfeld, R.
    Jung, C.
    Blehm, A.
    Lichtenberg, A.
    Kelm, M.
    Zeus, T.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2343 - 2343