Learning effect of humphrey matrix perimetry

被引:14
|
作者
Hong, Samin [1 ]
Na, Kyungdoo [1 ]
Kim, Chan Yun [1 ]
Seong, Gong Je [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; perimetry; frequency-doubling technology; Humphrey Matrix perimetry;
D O I
10.3129/i07-135
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Humphrey Matrix perimetry is a recent development in automated perimetry that uses frequency-doubling technology (FDT).We evaluated the learning effect of Humphrey Matrix perimetry with a full-threshold 30-2 strategy. Methods: Twenty-four patients with primary open-angle glaucoma and early visual field defects as assessed by standard automated perimetry and 24 healthy control subjects participated. All subjects had no prior experience with FDT visual field tests. Humphrey Matrix perimetry using a full-threshold 30-2 strategy was performed 3 times within I month.Various visual field indices were compared across multiple tests. Results: Mean deviation (MD) showed a larger defect at the first test than at the second and third tests (p < 0.001), and the mean total improvement of the MID was 2.80 decibels (dB) in the glaucoma group and 1.71 dB in the control group. Pattern standard deviations (PSDs) were decreased as the tests were repeated, but test duration, fixation losses, and false-positive or false-negative rate were not changed significantly. Additionally, the Glaucoma Hemifield Test (GHT) showed unstable results.
引用
收藏
页码:707 / 711
页数:5
相关论文
共 50 条
  • [21] A COMPARISON OF GOLDMAN AND HUMPHREY PERIMETRY IN PATIENTS WITH GLAUCOMA
    TROPE, GE
    BRITTAIN, R
    MORTIMER, CB
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1985, 20 (02): : 57 - 57
  • [22] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [23] COMPARISON OF GOLDMANN VERSUS HUMPHREY AUTOMATED PERIMETRY
    MINELLI, S
    STEINMAN, W
    FENDICK, M
    KATZ, LJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1104 - 1104
  • [24] COMPARISON BETWEEN FASTPAC AND CONVENTIONAL HUMPHREY PERIMETRY
    YOUNG, IM
    RAIT, JL
    GUEST, CS
    CARSON, CA
    TAYLOR, HR
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1994, 22 (02): : 95 - 99
  • [25] Comparison of Peristat Online Perimetry with the Humphrey Perimetry in a Clinic-Based Setting
    Lowry, Eugene A.
    Hou, Jing
    Hennein, Lauren
    Chang, Robert T.
    Lin, Shan
    Keenan, Jeremy
    Wang, Sean K.
    Ianchulev, Sean
    Pasquale, Louis R.
    Han, Ying
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (04):
  • [26] Impact of cataract surgery on the results of Frequency-Doubling Technology (FDT) perimetry using the Humphrey Matrix
    Abraham, C
    Sarenac, A
    Rzadkowski, M
    Kraff, M
    Tanna, AP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [27] The influence of instruction on frequency doubling technology perimetry and Humphrey Matrix results in normals and early glaucoma patients
    Takahashi, G
    Aoki, Y
    Koike, T
    Nakano, T
    Kitahara, K
    Demirel, S
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [28] Comparison of Humphrey Matrix Frequency Doubling Technology to Standard Automated Perimetry in Neuro-ophthalmic Disease
    Yoon, Michael K.
    Hwang, Thomas N.
    Day, Shelley
    Hong, Jenny
    Porco, Travis
    McCulley, Timothy J.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (02) : 211 - 215
  • [29] Comparison of portable perimetry tests with the Humphrey Field Analyzer
    Lin, Michael
    Zhao, Yan
    Freeman, Sandra
    Kang, Joyce
    De Arrigunaga, Sofia
    Friedman, David S.
    Liebman, Daniel Lee
    Roldan, Ana M.
    Chang, Dolly
    Elze, Tobias
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [30] A COMPARISON OF GOLDMANN AND HUMPHREY AUTOMATED PERIMETRY IN PATIENTS WITH GLAUCOMA
    TROPE, GE
    BRITTON, R
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1987, 71 (07) : 489 - 493