Anomalies in the measurement of changes in bone mineral density of the spine by dual-energy X-ray absorptiometry

被引:9
|
作者
Tothill, P [1 ]
Avenell, A
机构
[1] Univ Edinburgh, Western Gen Hosp, Dept Med Phys, Edinburgh EH4 2XU, Midlothian, Scotland
[2] Woolmanhill Hosp, Osteoporosis Res Unit, Aberdeen, Scotland
关键词
dual-energy absorptiometry; spine bone mineral; osteoporosis;
D O I
10.1007/s002239900502
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) is frequently used for longitudinal studies of bone mineral status because of the high precision obtained, but evidence is emerging that the accuracy of measurements of changes may be a Limitation because of artefacts of the analysis procedure, in particular, a dependence of the measured bone area (BA) on the bone mineral content (BMC). Results of spine bone mineral measurements taken at intervals with two DXA scanners, a Hologic QDR 1000W, and a Norland XR 26 HS, were examined. There was a consistent correlation between changes in BA and in BMC, with a slope of approximately 0.25 when expressed as percentages. A real change of BA of the magnitude observed is not feasible. There were no differences among the correlations for different instruments, genders, ages, or weight changes. There would appear to be an underestimation of changes in bone mineral density (BMD), but there is a possibility that some of the anomaly is manifested as an overestimation of a change in BMC. Phantom measurements were undertaken with the DXA scanners mentioned above and with a Lunar DPX. The phantoms consisted of simulations of the spine cut from aluminium sheet, so that the effective BMD could be varied. The dependence of the measured BA on BMC varied with the phantom outline, particularly the thickness of the transverse processes. Evidence was obtained of both an underestimate of BMD changes and an overestimate of BMC changes. There are errors in measuring spine changes, but these do not seem to be as serious as a previous report suggests for the Hologic scanner and are not likely to lead to misinterpretation of results.
引用
收藏
页码:126 / 133
页数:8
相关论文
共 50 条
  • [31] MEASUREMENT OF LUMBAR SPINAL BONE-MINERAL DENSITY IN PRETERM INFANTS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TSUKAHARA, H
    SUDO, M
    UMEZAKI, M
    FUJII, Y
    KURIYAMA, M
    YAMAMOTO, K
    ISHII, Y
    BIOLOGY OF THE NEONATE, 1993, 64 (2-3): : 96 - 103
  • [32] Dual-energy X-ray absorptiometry measurement of bone mineral density around cemented and cementless femoral prosthesis
    Kabak, S
    Halici, M
    Karaoglu, S
    Baktir, A
    Kula, M
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S73 - S73
  • [33] Dual-energy X-ray absorptiometry overestimates bone mineral density of the lumbar spine in persons with spinal cord injury
    W A Bauman
    E Schwartz
    I S Y Song
    S Kirshblum
    C Cirnigliaro
    N Morrison
    A M Spungen
    Spinal Cord, 2009, 47 : 628 - 633
  • [34] Dual-energy X-ray absorptiometry overestimates bone mineral density of the lumbar spine in persons with spinal cord injury
    Bauman, W. A.
    Schwartz, E.
    Song, I. S. Y.
    Kirshblum, S.
    Cirnigliaro, C.
    Morrison, N.
    Spungen, A. M.
    SPINAL CORD, 2009, 47 (08) : 628 - 633
  • [35] Dual-energy X-ray absorptiometry registers bone mineral in the liver
    Koufakis, M
    Söderborg, B
    Kallner, G
    Magi, A
    Svensson, U
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2001, 13 (05) : 523 - 528
  • [36] In vivo differences among scan modes in bone mineral density measurement at dual-energy X-ray absorptiometry
    Bandirali, Michele
    Sconfienza, Luca M.
    Aliprandi, Alberto
    Di Leo, Giovanni
    Marchelli, Daniele
    Ulivieri, Fabio M.
    Sardanelli, Francesco
    RADIOLOGIA MEDICA, 2014, 119 (04): : 257 - 260
  • [37] In vivo differences among scan modes in bone mineral density measurement at dual-energy X-ray absorptiometry
    Michele Bandirali
    Luca M. Sconfienza
    Alberto Aliprandi
    Giovanni Di Leo
    Daniele Marchelli
    Fabio M. Ulivieri
    Francesco Sardanelli
    La radiologia medica, 2014, 119 : 257 - 260
  • [38] Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
    Forogh, B.
    Ghasemzadeh, A.
    Salimzadeh, A.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2005, 30 (01) : 34 - 37
  • [39] Morphometric dual-energy X-ray absorptiometry of the spine: Report of a large series and correlation with axial bone mineral density
    Bianco, AC
    Malvestiti, LF
    Gouveia, CHA
    Wehba, S
    Lewin, S
    Marone, MMS
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (09) : 1605 - 1613
  • [40] The difference in spine specimen dual-energy X-ray absorptiometry bone mineral density between in situ and in vitro scans
    Tan, Juay Seng
    Kayanja, Mark M.
    St Clair, Selvon F.
    SPINE JOURNAL, 2010, 10 (09): : 784 - 788