Production and Performance of RE4 Resistive Plate Chambers for CMS experiment upgrade

被引:0
|
作者
Jeong, Min Soo [1 ]
Lee, Kyong Sei [1 ]
Park, Sung Keun [1 ]
机构
[1] Korea Univ, Korea Detector Lab, Seoul 136713, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fourth trigger station composed of 144 Resistive Plate Chambers (RPCs) is currently being constructed to enhance the efficiency of muon triggers in the end cap regions of the CMS detector. All new CMS end cap RPCs gaps are produced in accordance with QA at Korea Detector Laboratory in Korea. The qualified gas gaps passing QC have been delivered to three assembly sites; CERN in Switzerland, BARC in India, and Ghent University in Belgium for the RPCs detector assembly. We report the status of the detector production and performance of RE4 RPCs including the sophisticated test procedures for the selection of qualified detectors.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Operation and performance of the CMS Resistive Plate Chambers during LHC run II
    Eysermans, Jan
    Pedraza Morales, Maria Isabel
    31ST ANNUAL MEETING OF THE DIVISION OF PARTICLES AND FIELDS (DPYC) OF THE MEXICAN PHYSICAL SOCIETY, 2017, 912
  • [32] Aging studies for the CMS improved Resistive Plate Chambers
    Ferreira Filho, M. Barroso
    Samalan, A.
    Tytgat, M.
    El Sawy, M.
    Alves, G. A.
    Marujo, F.
    Coelho, E. A.
    Da Costa, E. M.
    Nogima, H.
    Santoro, A.
    De Souza, S. Fonseca
    Damiao, D. De Jesus
    Thiel, M.
    Amarilo, K. Mota
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Soultanov, G.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Shumka, E.
    Qian, S. J.
    Kou, H.
    Liu, Z. -A.
    Zhao, J.
    Song, J.
    Hou, Q.
    Diao, W.
    Cao, P.
    Avila, C.
    Barbosa, D.
    Cabrera, A.
    Florez, A.
    Fraga, J.
    Reyes, J.
    Assran, Y.
    Mahmoud, M. A.
    Mohammed, Y.
    Crotty, I.
    Laktineh, I.
    Grenier, G.
    Gouzevitch, M.
    Mirabito, L.
    Shchablo, K.
    Bagaturia, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1055
  • [33] Resistive Plate Chambers for the Pierre Auger array upgrade
    Lopes, L.
    Assis, P.
    Blanco, A.
    Cerda, M. A.
    Carolino, N.
    Cunha, O.
    Ferreira, M.
    Fonte, P.
    Mendes, L.
    Palka, M.
    Pereira, A.
    Pimenta, M.
    Tome, B.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [34] Beam test results on double-gap resistive plate chambers proposed for CMS experiment
    Abbrescia, M
    Bruno, G
    Colaleo, A
    Iaselli, G
    Lamanna, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Gianini, G
    Ratti, SP
    Vitulo, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3): : 135 - 148
  • [35] Beam test results on double-gap resistive plate chambers proposed for CMS experiment
    Abbrescia, M.
    Bruno, G.
    Colaleo, A.
    Iaselli, G.
    Lamanna, G.
    Loddo, F.
    Maggi, M.
    Marangelli, B.
    Natali, S.
    Nuzzo, S.
    Pugliese, G.
    Ranieri, A.
    Romano, F.
    Gianini, G.
    Ratti, S.P.
    et. al.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 414 (2-3): : 135 - 148
  • [36] The Resistive Plate Chambers of the ATLAS experiment: performance studies on Calibration Stream
    Mazzaferro, Luca
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 869 - 873
  • [37] Long-term performance and longevity studies o the CMS Resistive Plate Chambers
    Rabadan-Trejo, R. I.
    Fagot, A.
    Gul, M.
    Roskas, C.
    Tytgat, M.
    Zaganidis, N.
    Fonseca De Souza, S.
    Santoro, A.
    Torres Da Silva De Araujo, F.
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Qian, S. J.
    Han, D.
    Yi, W.
    Avila, C.
    Cabrera, A.
    Carrillo, C.
    Segura, M.
    Aly, S.
    Assran, Y.
    Mahrous, A.
    Mohamed, A.
    Combaret, C.
    Gouzevitch, M.
    Grenier, G.
    Lagarde, F.
    Laktineh, I. B.
    Mathez, H.
    Mirabito, L.
    Shchablo, K.
    Bagaturia, I.
    Lomidze, D.
    Lomidze, I.
    Pant, L. M.
    Bhatnagar, V.
    Gupta, R.
    Kumari, R.
    Lohan, M.
    Singh, J. B.
    Amoozegar, V.
    Boghrati, B.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [38] Glass resistive plate chambers in the OPERA experiment
    Candela, A.
    Carrara, E.
    D'Incecco, M.
    Di Giovanni, A.
    Dusini, S.
    Gustavino, C.
    Lindozzi, A.
    Longhin, A.
    Micanovic, S.
    Orlandi, D.
    Stipeevic, M.
    Tatananni, E.
    Zarnboni, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 206 - 208
  • [39] Assembly and Characterization of Resistive Plate Chambers in India for the CMS Detector
    Kumar, R.
    Mehta, A.
    Bhatnagar, V.
    Singh, J. B.
    Chudasama, R.
    Mohanty, A. K.
    Pant, L. M.
    Sehgal, R.
    Sehgal, S. T.
    Thomas, R. G.
    XXI DAE-BRNS HIGH ENERGY PHYSICS SYMPOSIUM, 2016, 174 : 553 - 557
  • [40] A prototype front end chip for the CMS resistive plate chambers
    Abbrescia, M
    Colaleo, A
    Guarrasi, L
    Iaselli, G
    Loddo, F
    Maggi, M
    Marangelli, B
    Natali, S
    Nuzzo, S
    Pugliese, G
    Ranieri, A
    Romano, F
    Altieri, S
    Belli, G
    Bruno, G
    Gianini, G
    Ratti, SP
    Riccardi, C
    Torre, P
    Viola, L
    Vitulo, P
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 457 - 461