An improved frequency meter for atomic magnetometer based on accurate time measurement

被引:1
|
作者
Jin, Kai [1 ]
Tang, Wangwang [1 ]
Deng, Wenjing [1 ]
Huang, Yan [1 ]
Ding, Xiaoxia [1 ]
Wu, Tianya [1 ]
Yang, Guoqing [2 ]
Huang, Guangming [1 ]
机构
[1] Cent China Normal Univ, Wuhan 430079, Hubei, Peoples R China
[2] Hangzhou Dianzi Univ, Hangzhou 310018, Zhejiang, Peoples R China
来源
IEICE ELECTRONICS EXPRESS | 2019年 / 16卷 / 23期
基金
中国国家自然科学基金;
关键词
Larmor precession frequency; frequency measurement; FPGA; TDC (time-to-digital converter); error analysis; SIGNALS;
D O I
10.1587/elex.16.20190310
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An improved frequency measurement method using FPGA and TDC (time-to-digital converter) is proposed, and its error analysis is carried out. Instead of measuring more precise counting values of equal-precision frequency measurement, this method obtains the converted frequency indirectly by accurately measuring the time of multiple measured signal cycles. It significantly improves the accuracy of the frequency meter in atomic magnetometer. The method is capable of eliminating the (2)1 error of reference signal counting of equal precision frequency measurement method, as well as avoiding the limitation that the measurement range of TDC cannot reach 0. With this method, a prototype of the frequency meter is implemented with very small size. Tests show that the prototype achieved 0.0042 Hz precision and 0.00056 Hz standard deviation in the frequency range of 70 kHz to 350 kHz at the output rate of 10 Hz.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] High frequency atomic magnetometer by use of electromagnetically induced transparency
    Katsoprinakis, G.
    Petrosyan, D.
    Kominis, I. K.
    PHYSICAL REVIEW LETTERS, 2006, 97 (23)
  • [42] Electromagnetic induction imaging with a scanning radio frequency atomic magnetometer
    Deans, Cameron
    Cohen, Yuval
    Yao, Han
    Maddox, Benjamin
    Vigilante, Antonio
    Renzoni, Ferruccio
    APPLIED PHYSICS LETTERS, 2021, 119 (01)
  • [43] Measurement of Linearly Polarized light Rotation Applied in Atomic Magnetometer
    Liu, Qiang
    Sun, Yudan
    Huang, Qiang
    Zeng, Xianjin
    Zhang, Junhai
    Sun, Weimin
    MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 2149 - +
  • [44] Can a quantum nondemolition measurement improve the sensitivity of an atomic magnetometer?
    Auzinsh, M
    Budker, D
    Kimball, DF
    Rochester, SM
    Stalnaker, JE
    Sushkov, AO
    Yashchuk, VV
    PHYSICAL REVIEW LETTERS, 2004, 93 (17) : 173002 - 1
  • [45] Suppression of Optical Frequency Shift Based on Single-Beam Compact SERF Atomic Magnetometer
    Miao, Kexuan
    Hu, Tao
    Guo, Qingqian
    Feng, Xiaoyu
    Zhang, Yin
    Chang, Yan
    Yang, Xiaodong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (15): : 15074011 - 15074019
  • [46] A Coil Constant Calibration Method Based on the Phase-Frequency Response of Alkali Atomic Magnetometer
    Yao, Han
    Ma, Danyue
    Zhao, Junpeng
    Lu, Jixi
    Ding, Ming
    PHOTONIC SENSORS, 2019, 9 (02) : 189 - 196
  • [47] A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators
    Gyure, B.
    Markus, B. G.
    Bernath, B.
    Muranyi, F.
    Simon, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (09):
  • [48] An improved meter for the measurement of gas flow rates
    Appleby, WG
    Avery, WH
    INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1943, 15 : 349 - 350
  • [49] Role of the primary radio frequency magnetic field distribution in atomic magnetometer based inductive measurements
    Bevington, P.
    Wright, L.
    Gartman, R.
    Chalupczak, W.
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (16)
  • [50] Fast measurement of magnetic gradient based on four-channel optically pumped atomic magnetometer
    Zhang, Yaohua
    Tang, Junjian
    Cao, Li
    Zhao, Binbin
    Li, Lin
    Zhai, Yueyang