Immediate Loading of Two Implants Supporting a Magnet Attachment-Retained Overdenture: One-Year Clinical Study

被引:20
|
作者
Pae, Ahran [1 ]
Kim, Jang-Wook [1 ]
Kwon, Kung-Rock [1 ]
机构
[1] Kyung Hee Univ, Sch Dent, Dept Prosthodont, Seoul 130701, South Korea
关键词
implant-retained mandibular overdentures; magnet attachments; immediate loading; STABILITY; SUCCESS;
D O I
10.1097/ID.0b013e3181f56deb
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this 1-year evaluation was to assess the stability of implants and the responses of the supporting tissues to magnet-retained mandibular implant overdentures. Methods: Six patients with completely edentulism were enrolled in this study. Each patient received 2 implants with sandblasted with large-grit and acid-etched surfaces in the interforaminal region. The implants were loaded immediately with magnet attachment-retained overdentures. The stability of the implants and periimplant tissues was examined by performing clinical examinations, resonance frequency analysis, and radiographic examinations at 1, 2, 6, 12, and 24 weeks and 1 year after surgery. Results: Two implants in 2 patients failed. The surviving implants were clinically and radiographically stable. The mean Implant Stability Quotient values were relatively stable, showing no significant differences (P > 0.05). The crestal bone changes were -1.18 +/- 0.68 mm, -1.35 +/- 0.69 mm, -1.47 +/- 0.68 mm, and -1.51 +/- 0.74 mm at the follow-up check performed at 6, 12, and 24 weeks and 1 year, respectively. The bleeding on probing index was not significant. Conclusions: The immediate loading of 2 implants using magnet attachment-retained mandibular overdentures may be a viable treatment option in cases of complete arch edentulism. This clinical approach offers increased stability to conventional dentures. (Implant Dent 2010;19:428-436)
引用
收藏
页码:428 / 436
页数:9
相关论文
共 50 条
  • [41] One-year follow-up study to evaluate the marginal bone resorption and attachment loss with customized post with stud attachment and prefabricated access post for mandibular overdenture
    Chaware, Sachin Haribhau
    Sachdev, Vibhuti Rohit
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (03): : 210 - 220
  • [42] Clinical evaluation of two ceramic inlay systems: A one-year study.
    Alkumru, HN
    Uctasli, S
    Gemalmaz, D
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1082 - 1082
  • [43] Immediate Versus Early Loading of Mini-Implants Supporting Mandibular Overdentures: A Preliminary 3-Year Clinical Outcome Report
    Maryod, Waleed Hamed
    Ali, Samer Mostafa
    Shawky, Ahmad Fathalla
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (06) : 553 - 560
  • [44] Immediate and delayed loading of two-piece reduced-diameter implants with locator-analog attachments in edentulous mandibles: One-year results from a randomized clinical trial examining clinical outcome and patient expectation
    Giannakopoulos, Nikolaos Nikitas
    Ariaans, Kirsten
    Eberhard, Lydia
    Klotz, Anna-Luisa
    Oh, Keunyoung
    Kappel, Stefanie
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (04) : 643 - 653
  • [45] Immediate Loading of Dental Implants Inserted in Edentulous Maxillas and Mandibles: 5-Year Results of a Clinical Study
    Shigehara, Satoshi
    Ohba, Seigo
    Nakashima, Ken
    Takanashi, Yoshiaki
    Asahina, Izumi
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 701 - 705
  • [46] Clinical application study of immediate implantation without bone grafting in maxillary molars: a clinical study with one-year follow up
    Liu, Lu
    Yu, Wen-hui
    Li, Xi-tao
    Zhao, Hui
    Yang, Jian-jun
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2022, 60 (03): : 332 - 336
  • [47] Prospective randomized controlled clinical study comparing two types of two-piece dental implants supporting fixed reconstructions - results at 1 year of loading
    Ebler, Sabine
    Ioannidis, Alexis
    Jung, Ronald E.
    Ammerle, Christoph H. F. H.
    Thoma, Daniel S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1169 - 1177
  • [48] A prospective study evaluating a protocol for 6weeks' loading of SLA implants in the posterior maxilla - One-year results
    Roccuzzo, M
    Wilson, TG
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (05) : 502 - 507
  • [49] Evaluation of masticatory efficiency and OHRQoL in implant-retained overdenture with different numbers of implant in the edentulous mandible: a one-year follow-up prospective study
    Sagheb, Kawe
    Wentaschek, Stefan
    Bjelopavlovic, Monika
    Berres, Manfred
    Diaz, Leonardo
    Fan, Shengchi
    Schiegnitz, Eik
    Al-Nawas, Bilal
    Sagheb, Keyvan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [50] Evaluation of masticatory efficiency and OHRQoL in implant-retained overdenture with different numbers of implant in the edentulous mandible: a one-year follow-up prospective study
    Kawe Sagheb
    Stefan Wentaschek
    Monika Bjelopavlovic
    Manfred Berres
    Leonardo Díaz
    Shengchi Fan
    Eik Schiegnitz
    Bilal Al-Nawas
    Keyvan Sagheb
    International Journal of Implant Dentistry, 10