Reconstruction of the flexor pulley -: The effect of the tension and source of the graft in an in vitro dog model

被引:10
|
作者
Seiler, JG
Uchiyama, AS
Ellis, RF
Amadio, PC
Gelberman, RH
An, KN
机构
[1] Mayo Clin & Mayo Fdn, Orthopaed Biomech Lab, Rochester, MN 55905 USA
[2] Emory Univ, Atlanta, GA 30322 USA
来源
关键词
D O I
10.2106/00004623-199805000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Flexor pulleys in the hindpaw digits of twenty-eight adult mixed-breed dogs were reconstructed in order to investigate the influence, on the reconstruction, of the source of the autogenous tissue (intrasynovial compared with extrasynovial tendon) and the tension applied during the repair. The ipsilateral peroneus longus tendon was used to reconstruct the A2 pulley,vith an around-the-bone technique in twenty-one digits; the graft was sutured at a tension of 0.49, 0.98, and 1.96 newtons in seven digits each. The flexor digitorum profundus tendon of an adjacent digit was used to reconstruct the A2 pulley, at a tension of 0.98 newton, in seven additional digits. The contralateral digits were used as controls for all twenty-eight treated digits. The digits were tested in a custom apparatus designed to measure the frictional force generated between the reconstructed pulley and the tendon beneath it. The frictional force did not differ significantly (p > 0.5) among the three groups repaired with peroneus longus tendon; however, the average value was more than five times that produced in the contralateral, control digits. The average frictional forces created by the flexor digitorum profundus grafts were similar to those in the contralateral, control digits. Reconstruction with the flexor digitorum profundus at a tension of 0.98 newton produced significantly less frictional force (p < 0.05) than that produced by the peroneus longus graft at the same tension. This in vitro model of reconstruction of the A2 pulley demonstrated that tendon from an intrasynovial source (the flexor digitorum profundus) produced less frictional resistance to gliding of the tendon than did tendon from an extrasynovial source (the peroneus longus), This result is consistent with previously published findings that intrasynovial tendons may make better grafts than extrasynovial tendons for the reconstruction of gliding flexor tendons because of decreased friction and better healing qualities. Intrasynovial tendons may also make better grafts for the reconstruction of flexor pulleys.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 50 条
  • [41] Effect of Posterolateral Bundle Graft Fixation Angles on Graft Tension Curves and Load Sharing in Double-Bundle Anterior Cruciate Ligament Reconstruction Using a Transtibial Drilling Technique
    Koga, Hideyuki
    Muneta, Takeshi
    Yagishita, Kazuyoshi
    Ju, Young-Jin
    Mochizuki, Tomoyuki
    Horie, Masafumi
    Nakamura, Tomomasa
    Okawa, Atsushi
    Sekiya, Ichiro
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (03): : 529 - 538
  • [42] The effect of platelet-rich plasma on patterns of gene expression in a dog model of anterior cruciate ligament reconstruction
    Xie, Xiaoxing
    Wu, Hua
    Zhao, Song
    Xie, Guoming
    Huangfu, Xiaoqiao
    Zhao, Jinzhong
    JOURNAL OF SURGICAL RESEARCH, 2013, 180 (01) : 80 - 88
  • [43] The effect of recombinant human bone morphogenetic protein-2 on femoral reconstruction with an intercalary allograft in a dog model
    Pluhar, GE
    Manley, PA
    Heiner, JP
    Vanderby, R
    Seeherman, HJ
    Markel, MD
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (02) : 308 - 317
  • [44] The Effect of Initial Graft Tension After Anterior Cruciate Ligament Reconstruction A Randomized Clinical Trial With 36-Month Follow-up
    Fleming, Braden C.
    Fadale, Paul D.
    Hulstyn, Michael J.
    Shalvoy, Robert M.
    Oksendahl, Heidi L.
    Badger, Gary J.
    Tung, Glenn A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (01): : 25 - 34
  • [45] The effect of femoral attachment location on anterior cruciate ligament reconstruction: graft tension patterns and restoration of normal anterior-posterior laxity patterns
    Zavras, TD
    Race, A
    Amis, AA
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (02) : 92 - 100
  • [46] Effect of hyaluronic acid on the excursion resistance of tendon graft: A biomechanical in vitro study in a modified human model
    Akasaka, Toshiki
    Nishida, Jun
    Imaeda, Toshihiko
    Shimamura, Tadashi
    Amadio, Peter C.
    An, Kai-Nan
    CLINICAL BIOMECHANICS, 2006, 21 (08) : 810 - 815
  • [47] Effect of the angle of the femoral and tibial tunnels in the coronal plane and incremental excision of the posterior cruciate ligament on tension of ananterior cruciate ligament graft: An in vitro study
    Simmons, R
    Howell, SM
    Hull, ML
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (06): : 1018 - 1029
  • [48] Fluid viscosity but not surface tension, determines the tamponade effect of intravitreal fluids in a novel in vitro eye model of retinal detachment
    Friehmann, Asaf
    Eng, Uri Zaretsky
    Rubowitz, Alexander
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 101
  • [49] Effect of Initial Graft Tension on Knee Osteoarthritis Outcomes After ACL Reconstruction: A Randomized Controlled Clinical Trial With 15-Year Follow-up
    Breker, Anika N.
    Badger, Gary J.
    Kiapour, Ata M.
    Costa, Meggin Q.
    Fleming, Emma N.
    Ferrara, Stacy L.
    Chrostek, Cynthia A.
    Fadale, Paul D.
    Hulstyn, Michael J.
    Shalvoy, Robert M.
    Gil, Holly C.
    Fleming, Braden C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (03)
  • [50] The effect of femoral tunnel position and graft tension on patellar contact mechanics and kinematics after medial patellofemoral ligament reconstruction (vol 42, pg 364, 2014)
    Stephen, J. M.
    Kader, D.
    Lumpaopong, P.
    Deehan, D. J.
    Amis, A. A.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2016, 44 (03): : NP11 - NP11