Reconstruction of the flexor pulley -: The effect of the tension and source of the graft in an in vitro dog model

被引:10
|
作者
Seiler, JG
Uchiyama, AS
Ellis, RF
Amadio, PC
Gelberman, RH
An, KN
机构
[1] Mayo Clin & Mayo Fdn, Orthopaed Biomech Lab, Rochester, MN 55905 USA
[2] Emory Univ, Atlanta, GA 30322 USA
来源
关键词
D O I
10.2106/00004623-199805000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Flexor pulleys in the hindpaw digits of twenty-eight adult mixed-breed dogs were reconstructed in order to investigate the influence, on the reconstruction, of the source of the autogenous tissue (intrasynovial compared with extrasynovial tendon) and the tension applied during the repair. The ipsilateral peroneus longus tendon was used to reconstruct the A2 pulley,vith an around-the-bone technique in twenty-one digits; the graft was sutured at a tension of 0.49, 0.98, and 1.96 newtons in seven digits each. The flexor digitorum profundus tendon of an adjacent digit was used to reconstruct the A2 pulley, at a tension of 0.98 newton, in seven additional digits. The contralateral digits were used as controls for all twenty-eight treated digits. The digits were tested in a custom apparatus designed to measure the frictional force generated between the reconstructed pulley and the tendon beneath it. The frictional force did not differ significantly (p > 0.5) among the three groups repaired with peroneus longus tendon; however, the average value was more than five times that produced in the contralateral, control digits. The average frictional forces created by the flexor digitorum profundus grafts were similar to those in the contralateral, control digits. Reconstruction with the flexor digitorum profundus at a tension of 0.98 newton produced significantly less frictional force (p < 0.05) than that produced by the peroneus longus graft at the same tension. This in vitro model of reconstruction of the A2 pulley demonstrated that tendon from an intrasynovial source (the flexor digitorum profundus) produced less frictional resistance to gliding of the tendon than did tendon from an extrasynovial source (the peroneus longus), This result is consistent with previously published findings that intrasynovial tendons may make better grafts than extrasynovial tendons for the reconstruction of gliding flexor tendons because of decreased friction and better healing qualities. Intrasynovial tendons may also make better grafts for the reconstruction of flexor pulleys.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 50 条
  • [1] Flexor tendon-pulley interaction after annular pulley reconstruction:: A biomechanical study in a dog model in vivo
    Nishida, J
    Seiler, JG
    Amadio, PC
    An, KN
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02): : 279 - 284
  • [2] Flexor tendon-pulley interaction after pulley reconstruction:: A biomechanical study in a human model in vitro
    Nishida, J
    Amadio, PC
    Bettinger, PC
    An, KN
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04): : 665 - 672
  • [3] Multiple-loop, uniform-tension flexor pulley reconstruction
    Naidu, Sanjiv H.
    Rinkus, Keith
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02): : 265 - 268
  • [4] EFFECT OF CYCLIC TENSION ON LACERATED FLEXOR TENDONS IN-VITRO
    TANAKA, H
    MANSKE, PR
    PRUITT, DL
    LARSON, BJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (03): : 467 - 473
  • [5] Adhesions in a murine flexor tendon graft model: Autograft versus allograft reconstruction
    Hasslund, Sys
    Jacobson, Justin A.
    Dadali, Tulin
    Basile, Patrick
    Ulrich-Vinther, Michael
    Soballe, Kjeld
    Schwarz, Edward M.
    O'Keefe, Regis J.
    Mitten, David J.
    Awad, Hani A.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (06) : 824 - 833
  • [6] Effect of Initial Graft Tension on Knee Stability and Graft Tension Pattern in Double-Bundle Anterior Cruciate Ligament Reconstruction
    Koga, Hideyuki
    Muneta, Takeshi
    Yagishita, Kazuyoshi
    Watanabe, Toshifumi
    Mochizuki, Tomoyuki
    Horie, Masafumi
    Nakamura, Tomomasa
    Otabe, Koji
    Sekiya, Ichiro
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (09): : 1756 - 1763
  • [7] The effect of graft-tunnel diameter disparity on Intraosseous healing of the flexor tendon graft in anterior cruciate ligament reconstruction
    Yamazaki, S
    Yasuda, K
    Tomita, F
    Minami, A
    Tohyama, H
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (04): : 498 - 505
  • [8] Two-bundle posterior cruciate ligament reconstruction - An in vitro analysis of graft placement and tension
    Mannor, DA
    Shearn, JT
    Grood, ES
    Noyes, FR
    Levy, MS
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (06): : 833 - 845
  • [9] The effect of anterior cruciate ligament graft rotation on knee laxity and graft tension: An in vitro biomechanical analysis
    Hame, SL
    Markolf, KL
    Gabayan, AJ
    Hunter, DM
    Davis, B
    Shapiro, MS
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01): : 55 - 60
  • [10] Effect of Initial Graft Tension During Calcaneofibular Ligament Reconstruction on Ankle Kinematics and Laxity
    Sakakibara, Yuzuru
    Teramoto, Atsushi
    Takagi, Tetsuya
    Yamakawa, Satoshi
    Okada, Yohei
    Shoji, Hiroaki
    Kobayashi, Takuma
    Fujimiya, Mineko
    Fujie, Hiromichi
    Watanabe, Kota
    Yamashita, Toshihiko
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (12): : 2935 - 2941