A wearable artificial kidney for patients with end-stage renal disease

被引:115
|
作者
Gura, Victor [1 ,2 ]
Rivara, Matthew B. [3 ]
Bieber, Scott [3 ]
Munshi, Raj [3 ,4 ,5 ]
Smith, Nancy Colobong [3 ,6 ]
Linke, Lori [3 ]
Kundzins, John [3 ]
Beizai, Masoud [7 ]
Ezon, Carlos [7 ]
Kessler, Larry [3 ,8 ]
Himmelfarb, Jonathan [3 ]
机构
[1] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Univ Washington, Div Nephrol, Kidney Res Inst, Seattle, WA 98195 USA
[4] Seattle Childrens Hosp, Dept Pediat, Div Nephrol, Seattle, WA USA
[5] Univ Washington, Seattle, WA 98195 USA
[6] Univ Washington, Med Ctr, Seattle, WA 98195 USA
[7] Blood Purificat Technol Inc, Beverly Hills, CA USA
[8] Univ Washington, Sch Publ Hlth, Dept Hlth Serv, Seattle, WA 98195 USA
关键词
QUALITY-OF-LIFE; LEFT-VENTRICULAR HYPERTROPHY; CONVENTIONAL HEMODIALYSIS; NOCTURNAL HEMODIALYSIS; MAINTENANCE DIALYSIS; PHYSICAL PERFORMANCE; PERITONEAL-DIALYSIS; FAMILY CAREGIVERS; FLUID REMOVAL; TIMES;
D O I
10.1172/jci.insight.86397
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
BACKGROUND. Stationary hemodialysis machines hinder mobility and limit activities of daily life during dialysis treatments. New hemodialysis technologies are needed to improve patient autonomy and enhance quality of life. METHODS. We conducted a FDA-approved human trial of a wearable artificial kidney, a miniaturized, wearable hemodialysis machine, based on dialysate-regenerating sorbent technology. We aimed to determine the efficacy of the wearable artificial kidney in achieving solute, electrolyte, and volume homeostasis in up to 10 subjects over 24 hours. RESULTS. During the study, all subjects remained hemodynamically stable, and there were no serious adverse events. Serum electrolytes and hemoglobin remained stable over the treatment period for all subjects. Fluid removal was consistent with prescribed ultrafiltration rates. Mean blood flow was 42 +/- 24 ml/min, and mean dialysate flow was 43 +/- 20 ml/min. Mean urea, creatinine, and phosphorus clearances over 24 hours were 17 +/- 10, 16 +/- 8, and 15 +/- 9 ml/min, respectively. Mean beta(2)-microglobulin clearance was 5 +/- 4 ml/min. Of 7 enrolled subjects, 5 completed the planned 24 hours of study treatment. The trial was stopped after the seventh subject due to device-related technical problems, including excessive carbon dioxide bubbles in the dialysate circuit and variable blood and dialysate flows. CONCLUSION. Treatment with the wearable artificial kidney was well tolerated and resulted in effective uremic solute clearance and maintenance of electrolyte and fluid homeostasis. These results serve as proof of concept that, after redesign to overcome observed technical problems, a wearable artificial kidney can be developed as a viable novel alternative dialysis technology.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Metabolic Derangements Seen in Chronic Kidney Disease and End-Stage Renal Disease Patients
    Gupta, Diptesh
    Misra, Madhukar
    HEMODIALYSIS: NEW METHODS AND FUTURE TECHNOLOGY, 2011, 171 : 113 - 119
  • [22] Association of Constipation with risk of end-stage renal disease in patients with chronic kidney disease
    Chung-Yen Lu
    Yin-Cheng Chen
    Yu-Wen Lu
    Chih-Hsin Muo
    Ray-E Chang
    BMC Nephrology, 20
  • [23] Kidney transplantation halts cardiovascular disease progression in patients with end-stage renal disease
    Meier-Kriesche, HU
    Schold, JD
    Srinivas, TR
    Reed, A
    Kaplan, B
    AMERICAN JOURNAL OF TRANSPLANTATION, 2004, 4 (10) : 1662 - 1668
  • [24] HCV in patients with end-stage renal disease
    Okoh, Emuejevoke J.
    Bucci, Jay R.
    Simon, James F.
    Harrison, Stephen A.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (08): : 2123 - 2134
  • [25] Tuberculosis in patients with end-stage renal disease
    Fang, HC
    Lee, PT
    Chen, CL
    Wu, MJ
    Chou, KJ
    Chung, HM
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2004, 8 (01) : 92 - 97
  • [26] Correlates for end-stage renal disease patients
    Yavuz, N
    Karatas, M
    Kilinç, S
    SCANDINAVIAN JOURNAL OF CARING SCIENCES, 2000, 14 (03) : 179 - 183
  • [27] Clinicopathological Features of Renal Cell Carcinomas in Patients with End-Stage Kidney Disease
    Tsuzuki, Toyonori
    Kondo, Tsunenori
    Sassa, Naoto
    Gotoh, Momokazu
    MODERN PATHOLOGY, 2018, 31 : 395 - 395
  • [28] Hypertension in end-stage renal disease patients
    Zager, P
    Nikolic, J
    Raj, DSC
    Tzamaloukas, A
    Campbell, M
    CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2000, 9 (03): : 279 - 283
  • [29] Cardiovascular disease in end-stage renal disease patients
    Collins, AJ
    Li, SL
    Ma, JZ
    Herzog, C
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) : S26 - S29
  • [30] Re: Bladder Capacity in Kidney Transplant Patients with End-Stage Renal Disease
    Song, Miho
    Park, Junsoo
    Kim, Young Hoon
    Han, Duck Jong
    Song, Sang Hoon
    Choo, Myung-Soo
    Hong, Bumsik
    JOURNAL OF UROLOGICAL SURGERY, 2015, 2 (01): : 44 - 44