Investigating of Precision Measurement on Ultrasonic Flow

被引:0
|
作者
Jiang Fangliang [1 ]
Ji Qizheng [1 ]
Zhai Dongwei [1 ]
Dong Yibo [1 ]
Dong Chun [1 ]
机构
[1] Beijing Orient Inst Measurement & Test, Beijing, Peoples R China
关键词
ultrasonic flow meter; flow measurement; method of time difference; digital correlation;
D O I
10.1117/12.2181965
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The flow rate is calculated via ultrasonic flow meter (UFM), which is through measuring the difference of time transmitting flow between flow direction and reverse direction. This paper describes the uncertainty analysis for the method of time difference which is commonly used in ultrasonic flow measurement, and the analysis of error source of uncertainty components as well as the general method of elimination. Based on the technique of pseudo random sequence, this paper presents a precise time difference method based on digital correlation technology, and its principle, realization way and uncertainty evaluation are introduced. On the DSP and FPGA system platform, an ultrasonic flow meter scheme based on the digital correlation technology is suggested.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] FLOW MEASUREMENT USING ULTRASONIC METHOD
    MULTON, F
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 1994, 49 (07): : 30 - 35
  • [22] ULTRASONIC TECHNIQUES FOR MEASUREMENT OF BLOOD FLOW
    FRANKLIN, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 175 - &
  • [23] ULTRASONIC BLOOD FLOW MEASUREMENT IN HAEMODIALYSIS
    SAMPSON, D
    PAPADIMITRIOU, M
    KULATILAKE, AE
    BMJ-BRITISH MEDICAL JOURNAL, 1970, 1 (5692): : 340 - +
  • [24] DOPPLER ULTRASONIC MEASUREMENT OF CAROTID FLOW
    MULLER, HR
    RADUE, EW
    SAIA, A
    PALLOTTI, C
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (01): : L91 - L95
  • [25] Ultrasonic measurement of unsteady gas flow
    Dane, HJ
    FLOW MEASUREMENT AND INSTRUMENTATION, 1997, 8 (3-4) : 183 - 190
  • [26] Influence of different ultrasonic transducers on the precision of fastening force measurement
    Liu, Yongmeng
    Zhi, Junjie
    Liu, Enxiao
    Chen, Yuanlin
    Wang, Xiaoming
    Sun, Chuanzhi
    Zifei, Cao
    Ma, Huiping
    Tan, Jiubin
    APPLIED ACOUSTICS, 2022, 185
  • [27] INVESTIGATING LEVELS OF PRECISION IN GENE EXPRESSION MEASUREMENT BY DIGITAL PCR
    Sanders, Rebecca
    Foy, Carole
    Mason, Deborah
    Huggett, Jim
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S609 - S610
  • [28] Research and Design for High Precision Ultrasonic Distance Measurement System
    Guo, Hua
    Yu, Shengwen
    MATERIALS ENGINEERING AND MECHANICAL AUTOMATION, 2014, 442 : 354 - +
  • [29] Comparison of flow rate calculation method for ultrasonic flow measurement
    Yu, Yang
    Zong, Guanghua
    Ding, Fenglin
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2013, 39 (01): : 37 - 41
  • [30] APPLICATIONS OF ULTRASONIC TECHNIQUES TO MEASUREMENT OF BLOOD FLOW
    FRANKLIN, D
    VANCITTE.RL
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1968, SU15 (01): : 61 - +