An enzyme-modified capillary as a platform for simultaneous fluorometric detection of D-glucose and L- lactate

被引:13
|
作者
Shoji, Atsushi [1 ,2 ]
Takahashi, Yusuke [1 ]
Osato, Saki [1 ]
Sugawara, Masao [1 ]
机构
[1] Nihon Univ, Coll Humanities & Sci, Dept Chem, Setagaya Ku, Tokyo 1568550, Japan
[2] Tokyo Univ Pharm & Life Sci, Sch Pharm, 1432-1 Horinouchi, Hachioji, Tokyo 1920392, Japan
关键词
Lipid layer; Patterning; Capillary-based sensor; Enzyme biosensor; LIPID-BILAYERS; BIOSENSOR; IMMUNOASSAY; PROTEIN; IMMOBILIZATION; DEHYDROGENASE; FABRICATION; LIPOSOMES; MEMBRANES; COATINGS;
D O I
10.1016/j.jpba.2018.09.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preparation of a glass capillary pattered with lipid layers on which lactate dehydrogenase (LDH) and glucose dehydrogenase (GDH) were regionally adsorbed and its application for simultaneous detection of D-glucose and L-lactate in human serum is described. A lipid layer was formed on the surface of BSA-unabsorbed octadecyltrichlorosilane (OTS) inner wall of a glass capillary. The electrostatic charge of the lipid layer was a key factor for adsorbing the enzymes on the lipid layer. The fluorescence intensities were observed at each enzyme site in the presence of diaphorase (DIA), beta-nicotinamide-adenine dinucleotide oxidized (NAD), resazurin, D-glucose and L-lactate. The fluorescence intensities at each enzyme site increased with an increase in the concentration of D-glucose and L-lactate=with the detection limits of 32 mu M and 4.9 mu M, respectively. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] Nanopore Identification of L-, D-Lactic Acids, D-Glucose and Gluconic Acid in the Serum of Human and Animals
    Jia, Wendong
    Ouyang, Yusheng
    Zhang, Shanyu
    Zhang, Panke
    Huang, Shuo
    SMALL METHODS, 2025, 9 (01):
  • [22] Synthesis of L-α-phosphatidyl-d-myo-inositol 3,5-bisphosphate from D-glucose
    Nishikawa, A
    Saito, S
    Hashimoto, Y
    Koga, K
    Shirai, R
    TETRAHEDRON LETTERS, 2001, 42 (52) : 9195 - 9198
  • [23] Enhanced measurement stability and selectivity for choline and acetylcholine by capillary electrophoresis with electrochemical detection at a covalently linked enzyme-modified electrode
    Inoue, T
    Kirchhoff, JR
    Hudson, RA
    ANALYTICAL CHEMISTRY, 2002, 74 (20) : 5321 - 5326
  • [24] THE SYNTHESES OF L-[C-11]-D-GLUCOSE AND RELATED-COMPOUNDS FOR THE MEASUREMENT OF BRAIN GLUCOSE-METABOLISM
    SHIUE, CY
    WOLF, AP
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 1985, 22 (02): : 171 - 182
  • [25] Classification of the mode of inhibition of high-affinity choline uptake using capillary electrophoresis with electrochemical detection at an enzyme-modified microelectrode
    Barkhimer, TV
    Kirchhoff, JR
    Hudson, RA
    Messer, WS
    ANALYTICAL BIOCHEMISTRY, 2005, 339 (02) : 216 - 222
  • [26] EFFECT OF VINBLASTINE ON INVITRO UTILIZATION OF D-GLUCOSE AND PRODUCTION OF L-LACTATE BY SMALL-INTESTINE OF RATS
    PRAKASH, O
    NAGCHAUDHURI, J
    INDIAN JOURNAL OF MEDICAL RESEARCH, 1979, 70 (OCT) : 669 - 673
  • [27] Effect of elevated dissolved carbon dioxide concentrations on growth of Corynebacterium glutamicum on D-glucose and L-lactate
    Baeumchen, Carsten
    Knoll, Arnd
    Husemann, Bernward
    Seletzky, Juri
    Maier, Bernd
    Dietrich, Carsten
    Amoabediny, Ghassem
    Buechs, Jochen
    JOURNAL OF BIOTECHNOLOGY, 2007, 128 (04) : 868 - 874
  • [28] SIMULTANEOUS D-GLUCOSE AND L-GLUCOSE UPTAKE BY RABBIT SMALL INTESTINAL BRUSH-BORDER MEMBRANE-VESICLES
    WOOD, C
    LAWRENCE, MJ
    WOOTTON, R
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1989, 17 (03) : 547 - 548
  • [29] A New Fluorescent PET Probe for Hydrogen Peroxide and its Use in Enzymatic Assays for L-Lactate and D-Glucose
    Groegel, Dominik B. M.
    Link, Martin
    Duerkop, Axel
    Wolfbeis, Otto S.
    CHEMBIOCHEM, 2011, 12 (18) : 2779 - 2785
  • [30] Selective detection Of L-glutamate using a microfluldic device integrated with an enzyme-modified pre-reactor and an electrochemical detector
    Hayashi, K
    Kurita, R
    Horiuchi, T
    Niwa, O
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (10): : 1249 - 1255