Impact of temperature and relative humidity on the near infrared spectroscopy measurements of cotton fiber micronaire

被引:7
|
作者
Zumba, Jimmy [1 ]
Rodgers, James [2 ]
Indest, Matthew [1 ]
机构
[1] ORISE, Oak Ridge, TN USA
[2] ARS, USDA, New Orleans, LA USA
关键词
fabrication; materials; measurement; properties; quality; testing; NIR; micronaire; cotton fiber; NIR; QUALITY; CLASSIFICATION; REFLECTANCE; COMPONENTS; YARNS;
D O I
10.1177/0040517517720499
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
A key cotton fiber property is micronaire. Micronaire can impact the fiber's quality, textile processing efficiency, and fabric dye consistency. Fiber micronaire is normally measured in a laboratory under tight standard temperature and relative humidity (RH) environmental conditions (21 +/- 1 degrees C, 65 +/- 2% RH). Near infrared (NIR) measurements have been performed both inside and outside of the laboratory, but measurements outside the laboratory have at times demonstrated reduced predictive capability, possibly due to the lack of standard environmental conditions. A program was implemented to determine the impact of non-standard conditions of temperature Tand relative humidity RH on NIR micronaire results for-bench-top and portable NIR instruments. Non-standard Tand RH resulted in varying fiber moisture, which impacted the NIR spectral response. The NIR micronaire results were impacted by the non-standard conditioning for all instruments, with the lower wavelength region (similar to 910-1680 nm) portable instrument impacted the most. The impacts and deviations were greater at high temperature/RH compared to low temperature/RH conditioning. These results provide a rationale for the deviations observed previously in NIR micronaire results for outside the laboratory micronaire measurements with portable NIR units.
引用
收藏
页码:2279 / 2291
页数:13
相关论文
共 50 条
  • [21] Analysis of sticky cotton by near-infrared spectroscopy
    Barton, FE
    Bargeron, JD
    Gamble, GR
    McAlister, DL
    Hequet, E
    APPLIED SPECTROSCOPY, 2005, 59 (11) : 1388 - 1392
  • [22] Temperature measurements of turbid aqueous solutions using near-infrared spectroscopy
    Kakuta, Naoto
    Arimoto, Hidenobu
    Momoki, Hideyuki
    Li, Fuguo
    Yamada, Yukio
    APPLIED OPTICS, 2008, 47 (13) : 2227 - 2233
  • [23] Clinical measurements with near infrared spectroscopy.
    Arnold, MA
    Eddy, CV
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U944 - U944
  • [24] Femtosecond laser-inscribed fiber-optic sensor for simultaneous temperature and relative humidity measurements
    Chen, Ning
    Liu, Changning
    Chen, Li
    Yang, Lun
    OPTICS AND LASER TECHNOLOGY, 2023, 164
  • [25] Discrimination of Bamboo Fiber and Ramie Fiber by Near Infrared Spectroscopy
    Wang Ge
    Huang An-min
    Hu Xiao-xia
    Chen Fu-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (09) : 2365 - 2367
  • [26] INTERPRETATION OF TEMPERATURE AND RELATIVE-HUMIDITY MEASUREMENTS IN A CALF HOUSE
    NICKS, B
    CANART, B
    DECHAMPS, P
    ANNALES DE MEDECINE VETERINAIRE, 1986, 130 (02) : 91 - 99
  • [27] Measuring the maturity of unopened cotton bolls with near infrared spectroscopy
    Long, Robert L.
    Bang, Michael P.
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2020, 28 (04) : 204 - 213
  • [28] Correction of Temperature Influence in Near Infrared Spectroscopy
    Sun Yan-hua
    Fan Yong-tao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (06) : 1690 - 1695
  • [29] Identification of cotton and cotton trash components by Fourier transform near-infrared spectroscopy
    Fortier, Chanel A.
    Rodgers, James E.
    Cintron, Michael S.
    Cui, Xiaoliang
    Foulk, Jonn A.
    TEXTILE RESEARCH JOURNAL, 2011, 81 (03) : 230 - 238
  • [30] Characteristic wavelength of textile fiber in Near Infrared spectroscopy
    Feng, HN
    Jin, SZ
    Gan, B
    ICO20: REMOTE SENSING AND INFRARED DEVICES AND SYSTEMS, 2006, 6031