Increased Excitability Induced in the Primary Motor Cortex by Transcranial Ultrasound Stimulation

被引:62
|
作者
Gibson, Benjamin C. [1 ]
Sanguinetti, Joseph L. [1 ,2 ]
Badran, Bashar W. [1 ,2 ,3 ,4 ]
Yu, Alfred B. [2 ]
Klein, Evan P. [1 ]
Abbott, Christopher C. [5 ]
Hansberger, Jeffrey T. [6 ]
Clark, Vincent P. [1 ,7 ,8 ]
机构
[1] Univ New Mexico, Dept Psychol, Psychol Clin Neurosci Ctr, Albuquerque, NM 87131 USA
[2] US Army Res Lab, Aberdeen Proving Ground, MD USA
[3] CUNY City Coll, Dept Biomed Engn, New York, NY USA
[4] Med Univ South Carolina, Dept Psychiat, Brain Stimulat Lab, Charleston, SC USA
[5] Univ New Mexico, Sch Med, Dept Psychiat, Albuquerque, NM 87131 USA
[6] US Army Res Lab, Redstone Arsenal, AL USA
[7] Univ New Mexico, Sch Med, Dept Neurosci, Albuquerque, NM 87131 USA
[8] Mind Res Network & LBERI, Albuquerque, NM 87106 USA
来源
FRONTIERS IN NEUROLOGY | 2018年 / 9卷
关键词
brain-stimulation; magnetic stimulation; excitability; neuroplasticity; excitation; pulsed ultrasound; NONINVASIVE BRAIN-STIMULATION; FOCUSED ULTRASOUND; MAGNETIC STIMULATION; INTERINDIVIDUAL VARIABILITY; CORTICAL PLASTICITY; THERAPEUTIC APPLICATIONS; EVOKED-POTENTIALS; LOW-INTENSITY; SOUND; TDCS;
D O I
10.3389/fneur.2018.01007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Transcranial Ultrasound Stimulation (tUS) is an emerging technique that uses ultrasonic waves to noninvasively modulate brain activity. As with other forms of non-invasive brain stimulation (NIBS), tUS may be useful for altering cortical excitability and neuroplasticity for a variety of research and clinical applications. The effects of tUS on cortical excitability are still unclear, and further complications arise from the wide parameter space offered by various types of devices, transducer arrangements, and stimulation protocols. Diagnostic ultrasound imaging devices are safe, commonly available systems that may be useful for tUS. However, the feasibility of modifying brain activity with diagnostic tUS is currently unknown. Objective: We aimed to examine the effects of a commercial diagnostic tUS device using an imaging protocol on cortical excitability. We hypothesized that imaging tUS applied to motor cortex could induce changes in cortical excitability as measured using a transcranial magnetic stimulation (TMS) motor evoked potential (MEP) paradigm. Methods: Forty-three subjects were assigned to receive either verum (n = 21) or sham (n = 22) diagnostic tUS in a single-blind design. Baseline motor cortex excitability was measured using MEPs elicited by TMS. Diagnostic tUS was subsequently administered to the same cortical area for 2 min, immediately followed by repeated post-stimulation MEPs recorded up to 16 min post-stimulation. Results: Verum tUS increased excitability in the motor cortex (from baseline) by 33.7% immediately following tUS (p = 0.009), and 32.4% (p = 0.047) 6 min later, with excitability no longer significantly different from baseline by 11 min post-stimulation. By contrast, subjects receiving sham tUS showed no significant changes in MEP amplitude. Conclusion: These findings demonstrate that tUS delivered via a commercially available diagnostic imaging ultrasound system transiently increases excitability in the motor cortex as measured by MEPs. Diagnostic tUS devices are currently used for internal imaging in many health care settings, and the present results suggest that these same devices may also offer a promising tool for noninvasively modulating activity in the central nervous system. Further studies exploring the use of diagnostic imaging devices for neuromodulation are warranted.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Systematic assessment of duration and intensity of anodal transcranial direct current stimulation on primary motor cortex excitability
    Tremblay, Sara
    Larochelle-Brunet, Felix
    Lafleur, Louis-Philippe
    El Mouderrib, Sofia
    Lepage, Jean-Francois
    Theoret, Hugo
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2016, 44 (05) : 2184 - 2190
  • [22] Effects of cerebellar transcranial alternating current stimulation on motor cortex excitability and motor function
    Naro, Antonino
    Bramanti, Alessia
    Leo, Antonino
    Manuli, Alfredo
    Sciarrone, Francesca
    Russo, Margherita
    Bramanti, Placido
    Calabro, Rocco Salvatore
    BRAIN STRUCTURE & FUNCTION, 2017, 222 (06): : 2891 - 2906
  • [23] Low-Frequency Repetitive Transcranial Magnetic Stimulation Targeted to Premotor Cortex Followed by Primary Motor Cortex Modulates Excitability Differently Than Premotor Cortex or Primary Motor Cortex Stimulation Alone
    Chen, Mo
    Deng, Huiqiong
    Schmidt, Rebekah L.
    Kimberley, Teresa J.
    NEUROMODULATION, 2015, 18 (08): : 678 - 684
  • [24] Modulating spinal cord excitability with repetitive transcranial magnetic stimulation on the primary motor cortex of human subjects
    Valero-Cabré, A
    Pascual-Leone, A
    ISEK 2004: XVTH CONGRESS OF THE INTERNATIONAL SOCIETY OF ELECTROPHYSIOLOGY & KINESIOLOGY ISEK 2004, 2004, : 1 - 12
  • [25] Effects of cerebellar transcranial alternating current stimulation on motor cortex excitability and motor function
    Antonino Naro
    Alessia Bramanti
    Antonino Leo
    Alfredo Manuli
    Francesca Sciarrone
    Margherita Russo
    Placido Bramanti
    Rocco Salvatore Calabrò
    Brain Structure and Function, 2017, 222 : 2891 - 2906
  • [26] Modulation of spinal cord excitability by subthreshold repetitive transcranial magnetic stimulation of the primary motor cortex in humans
    Valero-Cabré, A
    Oliveri, M
    Gangitano, M
    Pascual-Leone, A
    NEUROREPORT, 2001, 12 (17) : 3845 - 3848
  • [28] Increased primary motor cortical excitability by a single-pulse transcranial magnetic stimulation over the supplementary motor area
    Yuichiro Shirota
    Masashi Hamada
    Yasuo Terao
    Shinya Ohminami
    Ryosuke Tsutsumi
    Yoshikazu Ugawa
    Ritsuko Hanajima
    Experimental Brain Research, 2012, 219 : 339 - 349
  • [29] Comparative Study of Transcranial Magneto-Acoustic Stimulation and Transcranial Ultrasound Stimulation of Motor Cortex
    Wang, Huiqin
    Zhou, Xiaoqing
    Cui, Dong
    Liu, Ruixu
    Tan, Ruxin
    Wang, Xin
    Liu, Zhipeng
    Yin, Tao
    FRONTIERS IN BEHAVIORAL NEUROSCIENCE, 2019, 13
  • [30] Increased primary motor cortical excitability by a single-pulse transcranial magnetic stimulation over the supplementary motor area
    Shirota, Yuichiro
    Hamada, Masashi
    Terao, Yasuo
    Ohminami, Shinya
    Tsutsumi, Ryosuke
    Ugawa, Yoshikazu
    Hanajima, Ritsuko
    EXPERIMENTAL BRAIN RESEARCH, 2012, 219 (03) : 339 - 349