Why ambulatory blood pressure monitoring?

被引:10
|
作者
Punzi, HA [1 ]
机构
[1] Trin Hypertens & Diagnost Res Ctr, Carrollton, TX 75006 USA
关键词
ambulatory care; blood pressure; devices; equipment; hypertension; methodology; sphygmomanometers;
D O I
10.1093/ajhp/55.suppl_3.S12
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Factors that affect the reliability and accuracy of blood pressure measurements are reviewed, and new technologies for measuring blood pressure are discussed. Blood pressure measurements obtained in an office, hospital, or clinic are subject to variation and error. Reasons for variations include the wrong cuff size, improper inflation or deflation technique, and patient apprehension ("white-coat syndrome"). Ambulatory blood pressure monitoring (ABPM) involves the use of a fully automated standard arm cuff that is inflated at predetermined intervals by a small battery-powered pump unit. The most reliable ABPM method is the oscillometric method, which detects subtle changes in air pressure within the cuff system caused by fluctuations of the brachial artery. The process for interpreting 24-hour ABPM data is still evolving. Twenty-four-hour ABPM has been shown to eliminate white-coat hypertension and is also useful for assessing patients whose blood pressure is inappropriately high in the absence of end organ damage, monitoring persons at risk of developing hypertension because of their race or family history, determining a medication's 24-hour effect on blood pressure, and assessing the early-morning rapid rise in blood pressure, which has been linked to an increased risk of nonembolic stroke and myocardial infarction. ABPM enables identification of patients whose blood pressure is elevated in the office but normal at home, allows more appropriate screening of patients for clinical trials, gives reproducible values, and enables evaluation of drug duration and action.
引用
收藏
页码:S12 / S16
页数:5
相关论文
共 50 条
  • [41] Limitations of ambulatory blood pressure monitoring
    Palatini, P
    BLOOD PRESSURE MONITORING, 2001, 6 (04) : 221 - 224
  • [42] Ambulatory blood pressure monitoring in children
    Rajiv Sinha
    Janis Dionne
    Indian Pediatrics, 2011, 48 : 119 - 122
  • [43] Ambulatory blood pressure monitoring: mean blood pressure and blood pressure load
    Susan Koshy
    Colin Macarthur
    Sanjeev Luthra
    Mukesh Gajaria
    Denis Geary
    Pediatric Nephrology, 2005, 20 : 1484 - 1486
  • [44] Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring
    Katarzyna Lewandowska
    Stanisław Wasiliew
    Agata Kukfisz
    Michał Hofman
    Patrycja Woźniak
    Artur Radziemski
    Łukasz Stryczyński
    Dawid Lipski
    Andrzej Tykarski
    Paweł Uruski
    High Blood Pressure & Cardiovascular Prevention, 2023, 30 : 29 - 36
  • [45] Ambulatory blood pressure monitoring: mean blood pressure and blood pressure load
    Koshy, S
    Macarthur, C
    Luthra, S
    Gajaria, M
    Geary, D
    PEDIATRIC NEPHROLOGY, 2005, 20 (10) : 1484 - 1486
  • [46] Target Blood Pressure Values in Ambulatory Blood Pressure Monitoring
    Lewandowska, Katarzyna
    Wasiliew, Stanislaw
    Kukfisz, Agata
    Hofman, Michal
    Wozniak, Patrycja
    Radziemski, Artur
    Stryczynski, Lukasz
    Lipski, Dawid
    Tykarski, Andrzej
    Uruski, Pawel
    HIGH BLOOD PRESSURE & CARDIOVASCULAR PREVENTION, 2023, 30 (01) : 29 - 36
  • [47] Self monitoring versus ambulatory blood pressure monitoring
    Asmar, R
    Topouchian, J
    Darne, B
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2001, 94 (10): : 1093 - 1098
  • [48] Definition of terminology and criteria for ambulatory blood pressure monitoring in the Japanese Multicenter Study on Barnidipine with Ambulatory Blood Pressure Monitoring
    Imai, Y
    Shimada, K
    Kuwajima, I
    Abe, K
    BLOOD PRESSURE MONITORING, 2001, 6 : S9 - S15
  • [49] AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE REACTIVITY
    HARSHFIELD, GA
    PICKERING, TG
    PSYCHOPHYSIOLOGY, 1986, 23 (04) : 422 - 423
  • [50] Ambulatory blood pressure monitoring affects sleep quality and blood pressure
    Katsi, V.
    Souretis, G.
    Veioglanis, S.
    Gialernios, T.
    Tousoulis, D.
    Stefanadis, C.
    Kallikazaros, I.
    EUROPEAN HEART JOURNAL, 2012, 33 : 898 - 898