共 50 条
Investigation of Polymer and Nanoparticle Properties with Nicotinic Acid and p-Aminobenzoic Acid Grafted on Poly(ε-caprolactone)-Poly(ethylene glycol)-Poly(ε-caprolactone) via Click Chemistry
被引:32
|作者:
Suksiriworapong, Jiraphong
[1
]
Sripha, Kittisak
[2
]
Kreuter, Joerg
[3
]
Junyaprasert, Varaporn Buraphacheep
[1
]
机构:
[1] Mahidol Univ, Fac Pharm, Dept Pharm, Bangkok 10400, Thailand
[2] Mahidol Univ, Fac Pharm, Dept Pharmaceut Chem, Bangkok 10400, Thailand
[3] Goethe Univ Frankfurt, Biozentrum, Inst Pharmaceut Technol, D-60438 Frankfurt, Germany
关键词:
RING-OPENING POLYMERIZATION;
ALIPHATIC POLYESTERS;
EPSILON-CAPROLACTONE;
DIBLOCK COPOLYMERS;
TRIBLOCK COPOLYMER;
FUNCTIONALIZATION;
COMPLETENESS;
MICELLES;
MARKER;
URINE;
D O I:
10.1021/bc100270m
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
In this study, the grafting of nicotinic acid and p-aminobenzoic acid (PABA) onto poly(epsilon-caprolactone)-poly(ethylene glycol)-poly(epsilon-caprolactone) was performed by Huisgen's 1,3-dipolar cycloaddition, also known as click chemistry. Concentrations used for grafting were 0.10, 0.20, and 0.30 molar ratios with respect to caproyl units. The grafted copolymers were successfully obtained at all ratios as confirmed by NMR, GPC, and FT-IR According to the DSC results, the polymorphisms of these grafted copolymers were mostly changed from semicrystalline to amorphous depending on the type and the amount of grafting compounds. TGA thermograms showed different thermal stabilities of the grafted copolymers compared to the original copolymers. Cytotoxicity results from HUVEC models suggested that the toxicity of grafted nanoparticles increased with the molar ratios of grafting units. Due to differences in molecular structure between nicotinic acid and PABA, physicochemical properties (particle size and surface charge) of grafted copolymer nanoparticles were substantially different. With increasing molar ratio of the grafting units, the particle size of blank nanoparticles tended to increase, resulting from an increase in the hydrophobic fragments of the grafted copolymer. Ibuprofen was chosen as a model drug to evaluate the interaction between grafted copolymers and loaded drug. After ibuprofen loading, the particle size of the loaded nanoparticles of both grafted copolymers increased compared to that of the blank nanoparticles. Significant differences in loading capacity between nicotinic acid and PABA grafted copolymer nanoparticles were clearly shown. This is most likely a result of different compatibility between each grafting compound and ibuprofen, including hydrogen bond interaction, pi-pi stacking interaction, and steric hindrance.
引用
收藏
页码:582 / 594
页数:13
相关论文