A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA)

被引:6
|
作者
Mercader, Alexandra [1 ]
Roettinger, Timon [2 ]
Bigdeli, Amir [2 ]
Lueth, Tim C. [1 ]
Roettinger, Heinz [2 ]
机构
[1] Tech Univ Munich, Boltzmannstr 15, D-85748 Garching, Germany
[2] Chirurg Klinikum Munchen, Munich Ctr Arthroplasty, Sud Isarkanal 30, D-81379 Munich, Germany
关键词
Total knee Arthroplasty; Mechanism design; Rollback effect; COMPONENT ROTATION; KINEMATICS; ALIGNMENT; MOTION;
D O I
10.1186/s40634-020-00319-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Total knee arthroplasty (TKA) is nowadays performed as a standard procedure on a large number of patients suffering from arthrosis. Replacing the knee joint causes changes in the geometry and kinematics of the knee, which are unique to each individual. This research focuses on the method to detect these changes after TKA and on the impact on the knee movement. This approach could reduce complications in patients with post-operative pain and reduce the number of revisions. Methods A 3D model of a patient's knee was made by measuring the movement with a medically certified infrared stereo camera. This measurement was combined with the 3D model of the patient's bones, previously segmented from the CT scan. This model is printed in 3D, one part being the mechanism that follows the movement of the patient, and the other part being the 3D copy of the femur and tibia bones. The knee replacement operation is performed directly on the model and the resulting rollback is being measured before and after TKA. Results We observe a difference in the rollback before and after TKA on the 3D printed model. The variation in size and shape of the femoral implant compared to the natural femur condyles is one of the reasons for the changes in the rollback effect. The rollback is half as large after the prosthesis insertion, which confirms the fact that the femoral prosthesis geometry influences the knee kinematics. Conclusions In this study, a first 3D model combining the patient-specific kinematic and the geometry of his bones has been constructed. This model allows the surgeon to validate the plan of the operation, but also to understand the problems and consequences generated by the prosthesis insertion. The rollback is one of the most important motion of the knee joint and this behavior could be quantified, providing comparative analysis of the knee joint before and after the operation. As a future study, the model could be used to analyse more parameters of the TKA such as the impact of different implantation methods.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Novel patient-specific navigational template for total knee arthroplasty
    Gan, Yudong
    Xu, Dachuan
    Lu, Sheng
    Ding, Jing
    COMPUTER AIDED SURGERY, 2011, 16 (06) : 288 - 297
  • [42] Patient-specific instrumentation makes sense in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 489 - 497
  • [43] Method for selection of femoral component in total knee arthroplasty (tka)
    van den Heever, Dawie
    Scheffer, Cornie
    Erasmus, Pieter
    Dillon, Edwin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (01) : 23 - 30
  • [44] The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty
    Churchill, DL
    Incavo, SJ
    Johnson, CC
    Beynnon, BD
    JOURNAL OF ARTHROPLASTY, 2001, 16 (07): : 909 - 918
  • [45] Relationship between range of motion and femoral rollback in total knee arthroplasty
    de Carvalho, Lucio Honorio, Jr.
    Temponi, Eduardo Frois
    Machado Soares, Luiz Fernando
    Braga Goncalves, Matheus Jacques
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (01) : 1 - 5
  • [46] Functional Outcome and Quality of Life After Patient-Specific Instrumentation in Total Knee Arthroplasty
    Prakash, Jatin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 923 - 924
  • [47] Accuracy of a Novel 3D-Printed Patient-Specific Intramedullary Guide to Control Femoral Component Rotation in Total Knee Arthroplasty
    Sun, Mao-lin
    Zhang, Ying
    Peng, Yang
    Fu, De-jie
    Fan, Hua-quan
    He, Rui
    ORTHOPAEDIC SURGERY, 2020, 12 (02) : 429 - 441
  • [48] The Role of 3D-Printed Patient-Specific Instrumentation in Total Knee Arthroplasty: A Literature Review
    Keskinis, Anthimos
    Paraskevopoulos, Konstantinos
    Diamantidis, Dimitrios E.
    Ververidis, Athanasios
    Fiska, Aliki
    Tilkeridis, Konstantinos
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [49] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1724 - 1728
  • [50] Frontal plane alignment after total knee arthroplasty using patient-specific instruments
    Kiriakos Daniilidis
    Carsten O. Tibesku
    International Orthopaedics, 2013, 37 : 45 - 50