Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients

被引:10
|
作者
Zou, Qing [1 ,2 ]
Xu, Hua-yan [1 ]
Fu, Chuan [1 ]
Zhou, Xiao-yue [3 ]
Xu, Rong [1 ]
Yang, Meng-xi [4 ]
Yang, Zhi-gang [5 ]
Guo, Ying-kun [1 ]
机构
[1] Sichuan Univ, West China Univ Hosp 2, Dept Radiol, 20 Sect 3 South Renmin Rd, Chengdu 610041, Sichuan, Peoples R China
[2] Deyang Peoples Hosp, Dept Radiol, 173 Sect 3 Tai Shan Rd, Deyang 618400, Sichuan, Peoples R China
[3] Siemens Healthineers Ltd, MR Collaborat, Shanghai, Peoples R China
[4] Sichuan Univ, West China Univ Hosp 2, Minist Educ, Key Lab Birth Defects & Related Dis Women & Child, Chengdu 610041, Peoples R China
[5] Sichuan Univ, West China Hosp, Dept Radiol, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
关键词
Compressed sensing; Free-breathing; Arrhythmia; Pediatric; Cardiac magnetic resonance; HEART-DISEASE; RESOLUTION; VOLUMES; MRI;
D O I
10.1016/j.ijcard.2021.06.043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to explore the feasibility and accuracy of single-shot compressed-sensing (CS) cardiac magnetic resonance cine technology for the assessment of biventricular function and morphology in free-breathing (FB) pediatrics, especially those with arrhythmia. Methods: Seventy consecutive pediatric participants (6.27 +/- 3.8 years, range:0.5-14 years) were enrolled be-tween August 2019 and July 2020. Single-shot CS and conventional balanced steady-state free-precession (bSSFP) cine were obtained. The total scanning time, image quality and biventricular function parameters were compared for both sequences. Results: Single-shot CS cine had shorter acquisition time compared with the conventional bSSFP cine (all P < 0.001). The single-shot CS cine also had fewer artifacts than conventional bSSFP cine (breath-hold (BH): 4.6 +/- 0.6 vs. 4.3 +/- 0.6; FB without ongoing arrhythmia: 4.5 +/- 0.6 vs. 3.6 +/- 0.9; FB with ongoing arrhythmia: 4.7 +/- 0.5 vs. 2.6 +/- 1.1; all P < 0.05). No statistical difference of left ventricular parameters and right ventricular end-systolic volume/ejection fraction were found between the single-shot CS and conventional bSSFP cine in both BH and FB without ongoing arrhythmia group. There was an excellent correlation (R-2 = 0.60-0.98, all P < 0.001) and good intra-(range: R-2 = 0.57-0.99, P < 0.001)/inter-observer agreements (range: R-2 = 0.76-1, P < 0.001) for single-shot CS cine images in terms of biventricular function parameters. Conclusions: The single-shot CS cine can significantly reduce the image acquisition time, offering reliable quantification of biventricular function in free breathing condition for arrhythmic patients. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 45 条
  • [41] Dynamic Liver Magnetic Resonance Imaging in Free-Breathing Feasibility of a Cartesian T1-Weighted Acquisition Technique With Compressed Sensing and Additional Self-Navigation Signal for Hard-Gated and Motion-Resolved Reconstruction
    Kaltenbach, Benjamin
    Bucher, Andreas M.
    Wichmann, Julian L.
    Nickel, Dominik
    Polkowski, Christoph
    Hammerstingl, Renate
    Vogl, Thomas J.
    Bodelle, Boris
    INVESTIGATIVE RADIOLOGY, 2017, 52 (11) : 708 - 714
  • [42] High spatial resolution free-breathing 3D late gadolinium enhancement cardiac magnetic resonance imaging in ischaemic and non-ischaemic cardiomyopathy: quantitative assessment of scar mass and image quality
    Maurice B. Bizino
    Qian Tao
    Jacob Amersfoort
    Hans-Marc J. Siebelink
    Pieter J. van den Bogaard
    Rob J. van der Geest
    Hildo J. Lamb
    European Radiology, 2018, 28 : 4027 - 4035
  • [43] High spatial resolution free-breathing 3D late gadolinium enhancement cardiac magnetic resonance imaging in ischaemic and non-ischaemic cardiomyopathy: quantitative assessment of scar mass and image quality
    Bizino, Maurice B.
    Tao, Qian
    Amersfoort, Jacob
    Siebelink, Hans-Marc J.
    van den Bogaard, Pieter J.
    van der Geest, Rob J.
    Lamb, Hildo J.
    EUROPEAN RADIOLOGY, 2018, 28 (09) : 4027 - 4035
  • [44] Fast Brain Magnetic Resonance Imaging With Half-Fourier Acquisition With Single-Shot Turbo Spin Echo Sequence in Detection of Intracranial Hemorrhage and Skull Fracture in General Pediatric Patients Preliminary Results
    Kabakus, Ismail Mikdat
    Spampinato, Maria Vittoria
    Knipfing, Michael
    Cervantes, Gustavo
    Patel, Avni
    Eskandari, Ramin
    Yazdani, Milad
    PEDIATRIC EMERGENCY CARE, 2021, 37 (12) : E1168 - E1172
  • [45] Cardiac magnetic resonance whole-heart two-dimensional single-breathhold and navigator-guided three-dimensional free-breathing quantification of infarct size are accurate alternative techniques to standard two-dimensional late gadolinium enhancement imaging
    Manisha Bahl
    Otavio R Coelho-Filho
    Shuaib M Abdullah
    Raymond Y Kwong
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)