Performance comparison of piezo actuated valveless micropump with central excitation and annular excitation for biomedical applications

被引:8
|
作者
Mohith, S. [1 ]
Karanth, Navin P. [1 ]
Kulkarni, S. M. [1 ]
Desai, Vijay [1 ]
Patil, Suraj Suresh [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Mangalore 575025, Karnataka, India
关键词
amplified piezo actuator; disposable chamber; valveless; bossed diaphragm; annular excitation; PIEZOELECTRIC MICROPUMP; PUMP;
D O I
10.1088/1361-665X/ac1dbe
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years, microfluidic devices, particularly micropumps, are extensively utilized in biomedical applications. The micropump used in biomedical applications needs to possess precise delivery of fluids at requires rate and pressure. The present work proposes a valveless mechanical micropump with a disposable chamber integrated with a novel concept of annular excitation of the diaphragm to fulfil the need for precise delivery of fluids in biomedical applications. The proposed design of the micropump involves a reusable configuration of the amplified piezoelectric actuator (APA) for micropump actuation and a disposable pump chamber. The pumping of the fluids occurs through the oscillation of the silicone rubber bossed diaphragm. The performance of a mechanical micropump depends on the oscillation amplitude of the diaphragm. Thus, the conventional approach of central excitation of the bossed diaphragm is replaced by a novel approach of annular excitation intended to enhance the deflection range, thus the volumetric performance of the micropump. An experimental comparative study is carried out to assess the deflection characteristics of central excitation and annular excitation of the bossed diaphragm. The maximum deflection measured with the annularly excited configuration of the bossed diaphragm is about 1953.4 +/- 8.00 mu m at 150 V, 43.5 Hz, which is superior to the maximum deflection of centrally excited configuration delivering 717.99 +/- 4.00 mu m at 150 V, 9.5 Hz. Further, the experimental studies aimed to fabricate and characterize the micropump with central and annular excitation approaches. The proposed micropump with central excitation delivered the maximum water flow rate of about 7.192 +/- 0.147 ml min(-1) and backpressure of 0.294 kPa at 150 V, 5 Hz. However, the enhancement of the deflection characteristics of the bossed diaphragm under annular excitation leads to performance enhancement of the micropump with the flow rate of 95.10 +/- 0.444 ml min(-1) and backpressure of 1.472 kPa at 150, 30 Hz
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Comparison of the spectral excitation behavior of methane according to InP, GaSb, IC, and QC lasers as excitation source by sensor applications
    Milde, Tobias
    Hoppe, Morten
    Tatenguem, Herve
    Assmann, Christian
    Schade, Wolfgang
    Sacher, Joachim
    APPLIED OPTICS, 2019, 58 (10) : E84 - E91
  • [22] A review of charge excitation triboelectric nanogenerator performance enhancement and related applications
    Zhu, Xiaopeng
    Hao, Yijun
    Yang, Jiayi
    Su, Wei
    Zhang, Hongke
    Qin, Yong
    Zhang, Chuguo
    Li, Xiuhan
    APPLIED MATERIALS TODAY, 2024, 41
  • [23] Comparison between theoretical calculation and experimental results of excitation functions for production of relevant biomedical radionuclides
    Menapace, E
    Birattari, C
    Bonardi, ML
    Groppi, F
    Morzenti, S
    Zona, C
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 1638 - 1641
  • [24] Excitation enhancement of surface plasmon polaritons from an annular plasmonic coupler based on internal corrugations and a central nanowire
    A. Mudhafer
    Zahraa S. Khaleel
    Ra’ed Malallah
    Journal of Computational Electronics, 2021, 20 : 1721 - 1728
  • [25] Excitation enhancement of surface plasmon polaritons from an annular plasmonic coupler based on internal corrugations and a central nanowire
    Mudhafer, A.
    Khaleel, Zahraa S.
    Malallah, Ra'ed
    JOURNAL OF COMPUTATIONAL ELECTRONICS, 2021, 20 (05) : 1721 - 1728
  • [26] Performance Comparison of Low Current Measurement Systems for Biomedical Applications
    Kim, Dongsoo
    Tang, Wei
    Goldstein, Brian
    Weerakoon, Pujitha
    Montanaro, Hazael
    Martini, Berin
    Culurciello, Eugenio
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 3469 - 3472
  • [27] The dynamic excitation of a granular chain for biomedical ultrasound applications: contact mechanics finite element analysis and validation
    Gelat, P.
    Yang, J.
    Thomas, P. J.
    Hutchins, D. A.
    Akanji, O.
    Davis, L. A. J.
    Freear, S.
    Harput, S.
    Saffari, N.
    14TH ANGLO-FRENCH PHYSICAL ACOUSTICS CONFERENCE (AFPAC2015), 2016, 684
  • [28] Ultrasonic NDT on aluminum bars: An experimental performance comparison of excitation and processing techniques
    Bernieri, A.
    Ferrigno, L.
    Laracca, M.
    Rasile, A.
    Ricci, M.
    MEASUREMENT, 2018, 128 : 393 - 402
  • [29] 5 A review of microwave-induced thermoacoustic imaging: Excitation source, data acquisition system and biomedical applications
    Cui, Yongsheng
    Yuan, Chang
    Ji, Zhong
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (04)
  • [30] PROPER EXCITATION RATIO FOR IMPROVED PERFORMANCE DOUBLY FED INDUCTION GENERATOR IN WIND APPLICATIONS
    Elsonbaty, Nadia A.
    Enany, Mohamed A.
    Mohamed, Mostafa
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2018, 38 (04): : 152 - 159