Performance comparison of piezo actuated valveless micropump with central excitation and annular excitation for biomedical applications

被引:8
|
作者
Mohith, S. [1 ]
Karanth, Navin P. [1 ]
Kulkarni, S. M. [1 ]
Desai, Vijay [1 ]
Patil, Suraj Suresh [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Mangalore 575025, Karnataka, India
关键词
amplified piezo actuator; disposable chamber; valveless; bossed diaphragm; annular excitation; PIEZOELECTRIC MICROPUMP; PUMP;
D O I
10.1088/1361-665X/ac1dbe
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In recent years, microfluidic devices, particularly micropumps, are extensively utilized in biomedical applications. The micropump used in biomedical applications needs to possess precise delivery of fluids at requires rate and pressure. The present work proposes a valveless mechanical micropump with a disposable chamber integrated with a novel concept of annular excitation of the diaphragm to fulfil the need for precise delivery of fluids in biomedical applications. The proposed design of the micropump involves a reusable configuration of the amplified piezoelectric actuator (APA) for micropump actuation and a disposable pump chamber. The pumping of the fluids occurs through the oscillation of the silicone rubber bossed diaphragm. The performance of a mechanical micropump depends on the oscillation amplitude of the diaphragm. Thus, the conventional approach of central excitation of the bossed diaphragm is replaced by a novel approach of annular excitation intended to enhance the deflection range, thus the volumetric performance of the micropump. An experimental comparative study is carried out to assess the deflection characteristics of central excitation and annular excitation of the bossed diaphragm. The maximum deflection measured with the annularly excited configuration of the bossed diaphragm is about 1953.4 +/- 8.00 mu m at 150 V, 43.5 Hz, which is superior to the maximum deflection of centrally excited configuration delivering 717.99 +/- 4.00 mu m at 150 V, 9.5 Hz. Further, the experimental studies aimed to fabricate and characterize the micropump with central and annular excitation approaches. The proposed micropump with central excitation delivered the maximum water flow rate of about 7.192 +/- 0.147 ml min(-1) and backpressure of 0.294 kPa at 150 V, 5 Hz. However, the enhancement of the deflection characteristics of the bossed diaphragm under annular excitation leads to performance enhancement of the micropump with the flow rate of 95.10 +/- 0.444 ml min(-1) and backpressure of 1.472 kPa at 150, 30 Hz
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Performance Analysis of a Novel Piezo Actuated Valveless Micropump for Biomedical Application
    Santhya, Mohith
    Upadhya, Adithya Rajarama
    Panambur, Navin Karanth
    Kulkarni, Satyabodh Madhvarao
    INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN MECHANICAL ENGINEERING (ETIME-2019), 2020, 2236
  • [2] Performance analysis of valveless micropump with disposable chamber actuated through Amplified Piezo Actuator (APA) for biomedical application
    Mohith, S.
    Karanth, Navin P.
    Kulkarni, S. M.
    MECHATRONICS, 2020, 67 (67)
  • [3] DYNAMIC PERFORMANCE OF AN ELECTROMAGNETICALLY ACTUATED VALVELESS MICROPUMP
    Dinh, Thien X.
    Ogami, Yoshifumi
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE 2010), VOL 10, 2012, : 645 - 649
  • [4] SIMULATION AND DYNAMIC CHARACTERIZATION OF A 3-LAYER PIEZO-ACTUATED VALVELESS MICROPUMP SYSTEM
    SadAbadi, Hamid
    Chandrasekaran, Arvind
    Packirisamy, Muthukuraman
    Wuthrich, Rolf
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE 2010), VOL 10, 2012, : 333 - 337
  • [5] Valveless acoustic standing wave micropump for biomedical applications: A numerical study
    Nabavi, Majid
    Siddiqui, Kamran
    Dargahi, Javad
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2737 - 2740
  • [6] Effect of Flexure Hinge Geometry on Central Deflection of Piezo Actuated Diaphragm for Micropump
    Roopa, R.
    Karanth, Navin P.
    Kulkarni, S. M.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 2636 - 2638
  • [7] The impact of the excitation-signal asymmetry on the micropump performance
    Pecar, Borut
    Mozek, Matej
    Vrtacnik, Danilo
    ELEKTROTEHNISKI VESTNIK, 2019, 86 (05): : 274 - 282
  • [8] A low-energy-consumption electroactive valveless hydrogel micropump for long-term biomedical applications
    Kwon, Gu Han
    Jeong, Gi Seok
    Park, Joong Yull
    Moon, Jin Hee
    Lee, Sang-Hoon
    LAB ON A CHIP, 2011, 11 (17) : 2910 - 2915
  • [9] UNSTEADY ANALYSIS OF THE FLOW RECTIFICATION PERFORMANCE OF CONICAL MICRODIFFUSER VALVES FOR VALVELESS MICROPUMP APPLICATIONS
    Wang, Y. -C.
    Lin, S. -H.
    Jang, D.
    JOURNAL OF MECHANICS, 2010, 26 (03) : 299 - 307
  • [10] Experimental investigation on performance of disposable micropump with retrofit piezo stack actuator for biomedical application
    Mohith, S.
    Karanth, P. Navin
    Kulkarni, S. M.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2019, 25 (12): : 4741 - 4752