Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study

被引:2
|
作者
Stubig, T. [1 ]
Aidarous, H. [1 ]
Khalifa, A. [1 ]
Omar, M. [1 ]
Krettek, C. [1 ]
Pacha, T. Omar [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
3D imaging; Femur fractures; Antetorsion measurements; Rotational alignement; Intraoperative imaging; COMPUTER-NAVIGATION; SYSTEM;
D O I
10.1007/s00402-020-03432-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim This study aims to test the accuracy and feasibility of a measurement of femoral torsion of a 3D C-arm system (Linea aspera method) in a cadaver setting. Materials and methods A total of 11 intact femora were used. Schanz screws were inserted in the femoral bone in a parallel manner with the help of a fixed drill sleeve. Femur bones were then fractured in a controlled manner and three different internal and external torsion angles were fixed with the help of a Goniometer. After that, a 3D scan was performed. The 3D data set was analyzed using a radiologic software (Visage 7, Visage Imaging Inc, USA). Measurements were then compared in the two methods with a dependent t test. Results Specific measurements for different angles did not show any differences between those two utilities. Conclusion Intraoperative estimation of femoral antetorsion using a 3D C-Arm system and the Linea aspera method seems to be an accurate and feasible method. Nevertheless, more studies with higher patient numbers, comparison to CT seems to be the next step and can be recommended.
引用
收藏
页码:1739 / 1743
页数:5
相关论文
共 50 条
  • [21] Model of a vascular C-arm for 3D augmented fluoroscopy in interventional radiology
    Gorges, S
    Kerrien, E
    Berger, MO
    Trousset, Y
    Pescatore, J
    Anxionnat, R
    Picard, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 214 - 222
  • [22] C-arm CT-guided 3D navigation of percutaneous interventions
    Becker, H-C
    Meissner, O.
    Waggershauser, T.
    RADIOLOGE, 2009, 49 (09): : 852 - 855
  • [23] Calibration of the intrinsic parameters of a vascular C-arm for 3D enhanced fluoroscopy
    Gorges, S
    Kerrien, E
    Berger, MO
    Trousset, Y
    Pescatore, J
    Anxionnat, R
    Picard, L
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1307 - 1307
  • [24] Efficient segmentation of 3D fluoroscopic datasets from mobile C-arm
    Styner, M
    Talib, H
    Singh, D
    Nolte, LP
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1667 - 1678
  • [25] Preliminary Evaluation of a Mobile 3D C-Arm for Use in or Surgery Rooms
    Bian, J.
    Chen, J. F.
    Hussein, M.
    MEDICAL PHYSICS, 2024, 51 (10) : 7834 - 7835
  • [26] Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction
    Cañero, C
    Nofrerías, E
    Mauri, J
    Radeva, P
    TOPICS IN ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2002, 2504 : 322 - 335
  • [27] A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance
    Sheth, N. M.
    De Silva, T.
    Uneri, A.
    Ketcha, M.
    Han, R.
    Vijayan, R.
    Osgood, G. M.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2020, 47 (03) : 958 - 974
  • [28] Intraoperative transbronchial metallic coil marking guided by mobile 3D C-arm for resection of a small peripheral lung lesion
    Takizawa, Hiromitsu
    Miyamoto, Naoki
    Kawakita, Naoya
    Takeuchi, Taihei
    Sakamoto, Shinichi
    Sumitomo, Hiroyuki
    Morishita, Atsushi
    Toba, Hiroaki
    JOURNAL OF THORACIC DISEASE, 2024, 16 (11) : 7933 - 7940
  • [29] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697
  • [30] 3D C-arm navigated suture button implantation for AC joint dislocations - the pilot study
    Boehringer, Alexander
    Gebhard, Florian
    Dehner, Christoph
    Eickhoff, Alexander
    Cintean, Raffael
    Pankratz, Carlos
    Schuetze, Konrad
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (05) : 2431 - 2439