High speed cardiac cine MR imaging using keyhole method

被引:0
|
作者
Suga, M [1 ]
Matsuda, T [1 ]
Komori, M [1 ]
Minato, K [1 ]
Takahashi, T [1 ]
机构
[1] Nara Inst Sci & Technol, Ctr Informat Technol, Ikoma, Japan
来源
CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY | 1998年 / 1165卷
关键词
keyhole method; cine MRT; fast gradient echo imaging; left ventricular wall model; computer simulation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
While EGG-gated magnetic resonance imaging is widely used for cardiac imaging, it has several disadvantages such as long imaging time, respiratory artifacts, and motion artifacts induced by arrhythmia. An MR image can be acquired during about 0.3 seconds by using a fast gradient echo imaging method. When this method is continuously applied, only two to three images can be obtained during a single cardiac cycle. The goal of this study is to obtain cine MR images in a single cardiac cycle using a fast gradient echo imaging combined with "keyhole" method. The optimal condition of the keyhole method for cardiac cine imaging was considered with a computer simulation based on a simplified cardiac model. When the read-out direction was set parallel to the cardiac short axis, left ventricular motion was almost correctly reproduced by the keyhole method of which the acquisition time was reduced to one fourth.
引用
收藏
页码:92 / 97
页数:2
相关论文
共 50 条
  • [21] Uterine peristalsis shown on cine MR imaging using ultrafast sequence
    Nakai, A
    Togashi, K
    Yamaoka, T
    Fujiwara, T
    Ueda, H
    Koyama, T
    Kobayashi, H
    Kagimura, T
    Fujii, S
    Konishi, J
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) : 726 - 733
  • [22] Ultra-high-speed MR imaging
    Davis, CP
    McKinnon, GC
    Debatin, JF
    vonSchulthess, GK
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 297 - 311
  • [23] Cardiac cine MR-imaging at 3T: FLASH vs SSFP
    Tyler, Damian J.
    Hudsmith, Lucy E.
    Petersen, Steffen E.
    Francis, Jane M.
    Weale, Peter
    Neubauer, Stefan
    Clarke, Kieran
    Robson, Matthew D.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (05) : 709 - 715
  • [24] Comprehensive Segmentation of Cine Cardiac MR Images
    Fradkin, Maxim
    Ciofolo, Cybele
    Mory, Benoit
    Hautvast, Gilion
    Breeuwer, Marcel
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 178 - +
  • [25] Imaging 4D morphology and dynamics of mitral annulus in humans using cardiac cine MR feature tracking
    Leng, Shuang
    Zhang, Shuo
    Jiang, Meng
    Zhao, Xiaodan
    Wu, Rui
    Allen, John
    He, Ben
    Tan, Ru San
    Zhong, Liang
    SCIENTIFIC REPORTS, 2018, 8
  • [26] Imaging 4D morphology and dynamics of mitral annulus in humans using cardiac cine MR feature tracking
    Shuang Leng
    Shuo Zhang
    Meng Jiang
    Xiaodan Zhao
    Rui Wu
    John Allen
    Ben He
    Ru San Tan
    Liang Zhong
    Scientific Reports, 8
  • [27] CINE MR IMAGING IN AORTIC-STENOSIS
    DEROOS, A
    REICHEK, N
    AXEL, L
    KRESSEL, HY
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (03) : 421 - 425
  • [28] UTERINE CONTRACTILITY EVALUATED WITH CINE MR IMAGING
    Togashi, Kaori
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2009, 59 : 103 - 103
  • [29] Uterine junctional zone on cine MR imaging
    Nakai, A
    Togashi, K
    Yamaoka, T
    Koyama, T
    Ueda, H
    Konishi, J
    RADIOLOGY, 2000, 217 : 276 - 276
  • [30] PSEUDOCOARCTATION OF THE AORTA - PITFALL ON CINE MR IMAGING
    MIROWITZ, SA
    LEE, JKT
    GUTIERREZ, FR
    BROWN, JJ
    EILENBERG, SS
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (05) : 753 - 755