A fully automated system for inorganic antimony preconcentration and speciation in urine

被引:25
|
作者
Pacheco, Pablo H.
Gil, Raul A.
Martinez, Luis D.
Polla, Griselda
Smichowski, Patricia
机构
[1] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
[2] Natl Univ San Luis, Fac Chem Biochem & Pharm, Dept Analyt Chem, RA-5700 San Luis, Argentina
[3] Fondo Invest Cient & Tecnol FONCYT, Buenos Aires, DF, Argentina
[4] Unidad Actividad Fis, Comis Nacl Energia Atom, San Martin, Argentina
[5] Unidad Actividad Quim, Comis Nacl Energia Atom, San Martin, Argentina
关键词
L-methionine; antimony; speciation analysis; urine;
D O I
10.1016/j.aca.2007.09.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study was undertaken to ascertain the analytical capabilities of L-methionine immobilized on controlled pore glass for Sb preconcentration and speciation. A fully automated on-line system, implemented with hydride generation (HG) and inductively coupled plasma optical emission spectrometry (ICP OES), was used. Sb(III), at pH 10 was selectively retained in the column containing the immobilized aminoacid, while Sb(V) was not retained at all. A 30% HCl solution was used as eluent agent. Prior to total Sb determination, a pre-reduction step with thiourea was necessary. An on-line pH adjusting and pre-reduction of Sb(V) was achieved in a fully automated system. The detection limit for the preconcentration of 10 mL of an aqueous solution was 70 ng L-1 with a relative standard deviation of 2%. An enrichment factor of 20 was achieved when 10 mL of sample was passed through the system, reaching a throughput of 23 samples per hour. The method was successfully applied to the determination of Sb(III) and total Sb in urine. (C) 2007 Published by Elsevier B.V.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [31] ARSENIC SPECIATION IN URINE FROM HUMANS INTOXICATED BY INORGANIC ARSENIC COMPOUNDS - REPLY
    FARMER, JG
    LOVELL, MJ
    HUMAN TOXICOLOGY, 1985, 4 (05): : 531 - 532
  • [32] An automated preconcentration system for the determination of manganese in food samples
    Lemos, Valfredo Azevedo
    Novaes, Cleber Galvao
    Bezerra, Marcos Almeida
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2009, 22 (04) : 337 - 342
  • [33] A fully automated remote refraction system
    Dyer, AM
    Kirk, AH
    JOURNAL OF TELEMEDICINE AND TELECARE, 2000, 6 : 16 - 18
  • [34] Fully automated classroom attendance system
    Al Hajri E.
    Hafeez F.
    Ameer Azhar N.V.
    International Journal of Interactive Mobile Technologies, 2019, 13 (08) : 95 - 106
  • [35] FULLY AUTOMATED FEED AND WEIGHTING SYSTEM
    BISCHOFF, T
    LANDTECHNIK, 1974, 29 (02): : 78 - 80
  • [36] A FULLY AUTOMATED SERUM ELECTROPHORESIS SYSTEM
    FINK, PC
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1981, 19 (06): : 379 - 386
  • [37] Fully automated commando training system
    Rao, P. Sudhakara
    Narmada, A.
    2008 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY, 2008, : 54 - 59
  • [38] FULLY AUTOMATED EMULSION ANALYSIS SYSTEM
    AOKI, S
    HOSHINO, K
    NAKAMURA, M
    NIU, K
    NIWA, K
    TORII, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (04): : 466 - 472
  • [39] New fully automated depalletising system
    Aerosol Europe, 1998, 6 (04):
  • [40] A fully automated inpatient transport system
    Mendlovic, Joseph
    Gargir, Eli
    Katz, David E.
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (05) : 1049 - 1056