At the present, treatment planning systems (TPS) used in radiotherapy treatments use determinist correlations based on measurements in water to evaluate doses in the volume of interest and dose distributions around it. Nevertheless, it is well known that doses assigned with this type of planner can be problematic, especially in the presence of heterogeneities. The present work has developed a computational model using the Monte Carlo (MC) code MCNP5 (Monte Carlo N-Particle) for the simulation of a 6 MeV photon beam emitted by Elekta Precise medical linear accelerator treatment head. The model includes the major components of the accelerator head and the cube-shaped heterogeneous water tank "RFA-300". A low-density heterogeneity has been placed inside this water tank. It consists of a extruded polystyrene piece (97% air and 3% polystyrene) whose dimensions are 30 cm x 10 cm x 8 cm and with a density of 0.0311 g/cm(3). Calculations were performed for a photon beam setting 10 cm x 10 cm and 20 cm x 20 cm irradiation field sizes at 100 cm distance from source. The MC simulation is able to predict the absorbed dose distribution within the water tank using the *F8 or FMESH4 tally. These results have been compared with experimental values measured at the Hospital Clinic Universitari de Valencia. Dosimetric parameters calculated by simulation at the water tank and the experimental measures agreed, with an average deviation inside the heterogeneity region of 3%. Simulation results have been also compared with dose curves predicted by a commercial TPS in the same irradiation conditions, focusing attention on the accuracy that both systems reach in the dose calculation at the interphase zone and inside the heterogeneity. In contrast, TPS results overestimate the dose inside the heterogeneity and after it, with a maximum deviation of 7% for the 6 MeV photon beam and a field size of 20 cm x 20 cm. We can conclude that the algorithms of computation of the TPS are not able to predict the variation of dose in the heterogeneous zones with the same accuracy as MC methods, since MCNP5 provides more trustworthy results and fits the experimental values better in the heterogeneous region. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 50 条
  • [21] Monte Carlo-based inverse treatment planning
    Jeraj, R
    Keall, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1885 - 1896
  • [22] Treatment planning in 3 and 4 dimensions and the role of Monte Carlo techniques
    Paganetti, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2203 - 2206
  • [23] Effect of voxel size on Monte Carlo dose calculations for radiotherapy treatment planning
    Mora, G
    Pawlicki, T
    Maio, A
    Ma, CM
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 549 - 554
  • [24] Use of Monte Carlo computation in benchmarking radiotherapy treatment planning system algorithms
    Lewis, RD
    Ryde, SJS
    Seaby, AW
    Hancock, DA
    Evans, CJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1755 - 1764
  • [25] Considerations of MCNP Monte Carlo code to be used as a radiotherapy treatment planning tool
    Juste, B.
    Miro, R.
    Gallardo, S.
    Santos, A.
    Verdu, G.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2828 - 2831
  • [26] Modeling of radiotherapy x-ray sources for Monte Carlo treatment planning
    Garnica-Garza, H
    Van den Heuvel, F
    MEDICAL PHYSICS, 2002, 29 (06) : 1352 - 1352
  • [27] Monte Carlo treatment planning for molecular targeted radiotherapy within the MINERVA system
    Lehmann, J
    Siantar, CH
    Wessol, DE
    Wemple, CA
    Nigg, D
    Cogliati, J
    Daly, T
    Descalle, MA
    Flickinger, T
    Pletcher, D
    DeNardo, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 947 - 958
  • [28] Comparison of Monte Carlo collimator transport methods for photon treatment planning in radiotherapy
    Schmidhalter, D.
    Manser, P.
    Frei, D.
    Volken, W.
    Fix, M. K.
    MEDICAL PHYSICS, 2010, 37 (02) : 492 - 504
  • [29] Characterization of computer simulated radiotherapy beams for Monte-Carlo treatment planning
    Ma, CM
    RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03): : 329 - 344
  • [30] Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy
    Miura, Hideharu
    Masai, Norihisa
    Oh, Ryoong-Jin
    Shiomi, Hiroya
    Yamada, Kouichi
    Sasaki, Junichi
    Inoue, Toshihiko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 38 - 46