Risk of pump thrombosis and stroke in patients with continuous-flow left ventricular assist devices and gastrointestinal bleeding

被引:11
|
作者
Szymanski, Thomas W. [1 ]
Weeks, Phillip A. [1 ]
Patel, Chandni J. [2 ]
Jezovnik, Mateja K. [2 ]
Gulbis, Brian [1 ]
Nathan, Sriram S. [2 ]
Jumean, Marwan F. [2 ]
Radovancevic, Rajko [2 ]
Kar, Biswajit [2 ]
Gregoric, Igor D. [2 ]
机构
[1] Mem Hermann Hosp, Dept Pharm, Texas Med Ctr, Houston, TX USA
[2] Univ Texas Hlth Sci Ctr Houston, Dept Adv Cardiopulmonary Therapies & Transsplanta, Ctr Adv Heart Failure, 6400 Fannin St,Suite 2350, Houston, TX 77030 USA
关键词
gastrointestinal bleeding; heart assist device; left ventricular assist device; stroke; thrombosis; READMISSIONS; SUPPORT; HEART;
D O I
10.1111/aor.13751
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Gastrointestinal (GI) bleeding is a common complication following the placement of continuous-flow left ventricular assist devices (LVADs) in patients with advanced heart failure. Secondary events arising as a result of GI bleeding have not been well-described. Furthermore, attribution of these events to bleeding is complicated by the interruption or de-intensification of antithrombotic therapy, while bleeding is controlled. The purpose of this study was to assess the incidence of pump thrombosis and ischemic stroke in patients with LVADs who experience GI bleeding, while on support. This was a single-center, retrospective, observational cohort study of consecutive patients with LVADs implanted from January 2012 to June 2018. Patients were assigned to comparator groups based on whether they experienced GI bleeding while on LVAD support. The primary endpoint assessed was the composite of pump thrombosis or ischemic stroke. Secondary endpoints assessed included incidence of pump thrombosis or ischemic stroke. A total of 250 patients were included after screening for exclusion criteria, 101 (40.4%) in the GI bleeding group, and 149 (59.6%) in the non-bleeding group. The incidence of pump thrombosis or ischemic stroke was not significantly greater in patients experiencing GI bleeding [23 (22.8%) vs. 21 (14.1%);P = .09]; however, the incidence of ischemic stroke alone was significantly greater [17 (16.8%) vs. 10 (6.7%);P = .01]. We conclude that GI bleeding in LVAD patients may be associated with a greater risk of ischemic stroke.
引用
收藏
页码:1171 / 1175
页数:5
相关论文
共 50 条
  • [31] A Prospective Validation of the First Endoscopic Management Algorithm for Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices
    Axelrad, J. E.
    Pinsino, A.
    Thanataveerat, A.
    Cagliostro, B.
    Flannery, M. A.
    Ross, K.
    Te-Frey, R. T.
    Effner, L.
    Garan, A. R.
    Topkara, V. K.
    Takayama, H.
    Takeda, K.
    Naka, Y.
    Colombo, P.
    Gonda, T.
    Yuzefpolskaya, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S161 - S162
  • [32] Pre-Operative Ventilatory Inefficiency is Associated with Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices
    Yu, M. D.
    Newman, J.
    Brailovsky, Y.
    Liebo, M.
    Zolty, R.
    Lowes, B.
    Heroux, A.
    Raichlin, E.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S194 - S195
  • [33] Increased Aortic Stiffness is Associated with Higher Rates of Stroke, GI-bleeding and Pump Thrombosis in Continuous-Flow Left Ventricular Assist Device Patients
    Rosenblum, H.
    Pinsino, A.
    Demmer, R. T.
    Colombo, P. C.
    Yuzefpolskaya, M.
    Garan, A. R.
    Topkara, V. K.
    Gaudig, A.
    Pineda, M. T.
    Naka, Y.
    Takayama, H.
    Takeda, K.
    Castagna, F.
    Willey, J. Z.
    McDonnell, B. J.
    Cockcroft, J. R.
    Stohr, E. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S32 - S32
  • [34] Thalidomide Use Reduces Risk of Refractory Gastrointestinal Bleeding in Patients with Continuous Flow Left Ventricular Assist Devices
    Namdaran, P.
    Zikos, T. A.
    Pan, J. Y.
    Banerjee, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S192 - S192
  • [35] Thalidomide Use Reduces Risk of Refractory Gastrointestinal Bleeding in Patients with Continuous Flow Left Ventricular Assist Devices
    Namdaran, Parhum
    Zikos, Thomas A.
    Pan, Jennifer Y.
    Banerjee, Dipanjan
    ASAIO JOURNAL, 2020, 66 (06) : 645 - 651
  • [36] Pre-Operative Right Ventricular Dysfunction Is Associated With Gastrointestinal Bleeding in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Sparrow, Christopher T.
    Nassif, Michael E.
    Raymer, David S.
    Novak, Eric
    LaRue, Shane J.
    Schilling, Joel D.
    JACC-HEART FAILURE, 2015, 3 (12) : 956 - 964
  • [37] Pre-Operative Right Ventricular Dysfunction is Not Predictive of Gastrointestinal Bleeding in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Stegman, Matthew
    Balasubramanian, Neelam
    Liebo, Max
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (08) : S131 - S131
  • [38] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Cho, Sung-Min
    Moazami, Nader
    Katz, Stuart
    Bhimraj, Adarsh
    Shrestha, Nabin K.
    Frontera, Jennifer A.
    NEUROCRITICAL CARE, 2019, 31 (01) : 72 - 80
  • [39] Stroke Risk Following Infection in Patients with Continuous-Flow Left Ventricular Assist Device
    Sung-Min Cho
    Nader Moazami
    Stuart Katz
    Adarsh Bhimraj
    Nabin K. Shrestha
    Jennifer A. Frontera
    Neurocritical Care, 2019, 31 : 72 - 80
  • [40] Lack of Influence of Pulsatility on Gastrointestinal Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
    Edwards, Adam L.
    Pamboukian, Salpy V.
    George, James F.
    Wilcox, C. Mel
    Peter, Shajan
    GASTROENTEROLOGY, 2014, 146 (05) : S703 - S703