Comparing energy sources for surgical ablation of atrial fibrillation: a Bayesian network meta-analysis of randomized, controlled trials

被引:17
|
作者
Phan, Kevin [1 ,2 ]
Xie, Ashleigh [1 ]
Kumar, Narendra [3 ,4 ]
Wong, Sophia [5 ]
Medi, Caroline [6 ]
La Meir, Mark [3 ,4 ,7 ]
Yan, Tristan D. [1 ,6 ]
机构
[1] Macquarie Univ, Collaborat Res CORE Grp, Sydney, NSW 2109, Australia
[2] Univ Sydney, Sydney Med Sch, Westmead Hosp, Sydney, NSW 2006, Australia
[3] Univ Limburg, Acad Hosp Maastricht, Dept Cardiothorac Surg & Cardiol, Maastricht, Netherlands
[4] Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
[5] Gosford Dist Hosp, Gosford, NSW, Australia
[6] Royal Prince Alfred Hosp, Dept Cardiol & Cardiothorac Surg, Sydney, NSW, Australia
[7] Univ Hosp Brussels, Brussels, Belgium
关键词
Atrial fibrillation; Ablation; Randomized controlled trial; Meta-analysis; MITRAL-VALVE SURGERY; VALVULAR HEART-DISEASE; MAZE PROCEDURE; RADIOFREQUENCY ABLATION; CARDIAC-SURGERY; MICROWAVE ABLATION; BEATING HEART; PREDICTORS; EFFICACY; CATHETER;
D O I
10.1093/ejcts/ezu408
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Simplified maze procedures involving radiofrequency, cryoenergy and microwave energy sources have been increasingly utilized for surgical treatment of atrial fibrillation as an alternative to the traditional cut-and-sew approach. In the absence of direct comparisons, a Bayesian network meta-analysis is another alternative to assess the relative effect of different treatments, using indirect evidence. A Bayesian meta-analysis of indirect evidence was performed using 16 published randomized trials identified from 6 databases. Rank probability analysis was used to rank each intervention in terms of their probability of having the best outcome. Sinus rhythm prevalence beyond the 12-month follow-up was similar between the cut-and-sew, microwave and radiofrequency approaches, which were all ranked better than cryoablation (respectively, 39, 36, and 25 vs 1%). The cut-and-sew maze was ranked worst in terms of mortality outcomes compared with microwave, radiofrequency and cryoenergy (2 vs 19, 34, and 24%, respectively). The cut-and-sew maze procedure was associated with significantly lower stroke rates compared with microwave ablation [odds ratio <0.01; 95% confidence interval 0.00, 0.82], and ranked the best in terms of pacemaker requirements compared with microwave, radiofrequency and cryoenergy (81 vs 14, and 1, <0.01% respectively). Bayesian rank probability analysis shows that the cut-and-sew approach is associated with the best outcomes in terms of sinus rhythm prevalence and stroke outcomes, and remains the gold standard approach for AF treatment. Given the limitations of indirect comparison analysis, these results should be viewed with caution and not over-interpreted.
引用
收藏
页码:201 / 211
页数:11
相关论文
共 50 条
  • [31] Surgical ablation for treatment of atrial fibrillation in cardiac surgery: a cumulative meta-analysis of randomised controlled trials
    Phan, Kevin
    Xie, Ashleigh
    La Meir, Mark
    Black, Deborah
    Yan, Tristan D.
    HEART, 2014, 100 (09) : 722 - 730
  • [32] Radiofrequency Versus Cryoballoon Ablation in the Treatment of Paroxysmal Atrial Fibrillation: A Meta-Analysis of Randomized Controlled Trials
    Hussain, Nasir
    Hachem, Ali
    Tahboub, Housam
    Banfield, Laura
    Soni, Ronak
    Patel, Dhara
    Deoker, Abhizith
    Kanjwal, Khalil
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) : 594 - 597
  • [33] Cryoballoon or Irrigated Radiofrequency Ablation for Atrial Fibrillation: A Systematic Review and Meta-analysis of Randomized Controlled Trials
    Carmo, Joao
    Costa, Francisco M.
    Cavaco, Diogo
    Ferreira, Jorge
    Lopes, Nicodemus
    Carmo, Pedro
    Morgado, Francisco
    Adragao, Pedro
    CIRCULATION, 2016, 134
  • [34] Catheter ablation for treatment of patients with atrial fibrillation and heart failure: a meta-analysis of randomized controlled trials
    Yingxu Ma
    Fan Bai
    Fen Qin
    Yixi Li
    Tao Tu
    Chao Sun
    Shenghua Zhou
    Qiming Liu
    BMC Cardiovascular Disorders, 18
  • [35] Meta-Analysis of Randomized Controlled Trials of Atrial Fibrillation Ablation With Pulmonary Vein Isolation Versus Without
    Sau, Arunashis
    Howard, James P.
    Al-Aidarous, Sayed
    Ferreira-Martins, Joao
    Al-Khayatt, Becker
    Lim, P. Boon
    Kanagaratnam, Prapa
    Whinnett, Zachary, I
    Peters, Nicholas S.
    Sikkel, Markus B.
    Francis, Darrel P.
    Sohaib, S. M. Afzal
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (08) : 968 - 976
  • [36] Cryoballoon or Irrigated Radiofrequency Ablation for Atrial Fibrillation: A Systematic Review and Meta-analysis of Randomized Controlled Trials
    Carmo, Joao
    Costa, Francisco M.
    Cavaco, Diogo
    Ferreira, Jorge
    Lopes, Nicodemus
    Carmo, Pedro
    Morgado, Francisco
    Adragao, Pedro
    CIRCULATION, 2016, 134
  • [37] EFFICACY OF HYBRID CONVERGENT ABLATION FOR ATRIAL FIBRILLATION: A SYSTEMATIC REVIEW AND META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS
    Saleh, Othman
    Abuelazm, Mohamed
    Albakri, Khaled
    Altiti, Abdalrahman
    Dajani, Majd
    Khraisat, Nadeen Majed
    Alhawi, Omar
    Shalabi, Reem
    El Gazzar, Walaa
    Ghaly, Ramy
    Abdelazeem, Basel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 198 - 198
  • [38] Approach to the Catheter Ablation Technique of Paroxysmal and Persistent Atrial Fibrillation: A Meta-Analysis of the Randomized Controlled Trials
    Parkash, Ratika
    Tang, Anthony S. L.
    Sapp, John L.
    Wells, George
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (07) : 729 - 738
  • [39] Catheter ablation for treatment of patients with atrial fibrillation and heart failure: a meta-analysis of randomized controlled trials
    Ma, Yingxu
    Bai, Fan
    Qin, Fen
    Li, Yixi
    Tu, Tao
    Sun, Chao
    Zhou, Shenghua
    Liu, Qiming
    BMC CARDIOVASCULAR DISORDERS, 2018, 18
  • [40] Comparison of ablation efficacy with cryoballoon or radiofrequency for the treatment of atrial fibrillation: a meta-analysis of randomized controlled trials
    Zheng, Yong
    Chen, Hong-Wu
    Jia, Dong-Yu
    Gu, Qiang
    Peng, Huai-Ming
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14309 - 14320