Seismic behaviour of concrete-filled steel tubular columns with internal H-section steel under pure torsion and compression-torsion loads

被引:8
|
作者
Pi, Zheng-Bo [1 ]
Su, Meni [2 ]
Peng, Yuan-Yuan [3 ]
Wang, Yu-Hang [1 ,4 ]
Luo, Wei [5 ]
Lan, Yong-Sen [5 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing, Peoples R China
[2] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[3] Chongqing Univ, Dept Capital Construct & Planning, Chongqing, Peoples R China
[4] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing, Peoples R China
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing, Peoples R China
关键词
Compressive torsional capacity; Concrete-filled steel tube columns; Energy dissipation capacity; Torsional behaviour; Torsional stiffness degradation; Shear capacity of steel; TUBE COLUMNS; TESTS;
D O I
10.1016/j.engstruct.2020.110761
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel tube (CFST) columns have been widely used in the construction industry because of their excellent compression capacity and torsion resistance. Regarding traditional CFST columns, the H-CFST column with an additional H-section steel member embedded in the core concrete provides improved fire and compression resistance. In this study, the seismic performance of nine H-CFST columns under cyclic torsional and compression-cyclic torsional loads was experimentally analysed. In the experiments, the failure mode, torque versus torsional angle hysteresis, torque versus torsional angle skeleton, torsional stiffness degradation, and energy dissipation capacity were determined. The hysteretic curves of the H-CFST columns under torsion were relatively plump in shape and exhibited no 'pinching' phenomenon, and the torsional stiffness of the H-CFST columns under unloading and reverse loading was approximately equal to the initial torsional stiffness. In addition, the applied compression had remarkable effects on the torsional capacity, torsional ductility, torsional stiffness, and hysteretic loop energy dissipation of the H-CFST columns. The shear capacities of the steel and concrete under normal stress or combined normal and shear stress were determined based on the latest theories and test results. Moreover, design method for the determination of the torsional capacity of H-CFST columns under compressive torsion is proposed based on the test results, and the theoretical contribution ratio of the H-section steel, steel tube, and concrete in the H-CFST columns to the torsional capacity was determined.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Behavior of concrete-filled double skin steel tubular columns with octagon section under axial compression
    Yang J.
    Xu H.
    Peng G.
    Frontiers of Architecture and Civil Engineering in China, 2008, 2 (3): : 205 - 210
  • [32] RESEARCH ON SEISMIC BEHAVIOR OF CONCRETE-FILLED L-SECTION STEEL TUBULAR COLUMNS
    Zhang, Ji-Cheng
    Shen, Zu-Yan
    Zhou, Hai-Jun
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 1924 - 1929
  • [33] Axial load behaviour of concrete-filled steel tubular columns
    De Nardin, S.
    El Debs, A. L. H. C.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2007, 160 (01) : 13 - 22
  • [34] Effect of stiffeners on the eccentric compression behaviour of square concrete-filled steel tubular columns
    Yuan, Fang
    Huang, Hong
    Chen, Mengcheng
    THIN-WALLED STRUCTURES, 2019, 135 (196-209) : 196 - 209
  • [35] Behaviour of concrete-filled steel tubular stub columns subjected to axially local compression
    Han, Lin-Hai
    Liu, Wei
    Yang, You-Fu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (04) : 377 - 387
  • [36] Performance of concrete-filled thin-walled steel tubes under pure torsion
    Han, Lin-Hai
    Yao, Guo-Huang
    Tao, Zhong
    THIN-WALLED STRUCTURES, 2007, 45 (01) : 24 - 36
  • [37] Cyclic behaviour of concrete-filled steel tubular (CFST) members with circumferential gap under combined compression-bending-torsion load
    Liao, Feiyu
    Han, Hao
    Wang, Yuhang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2019, 52 (07): : 57 - 68
  • [38] Behaviour of Recycled Aggregate Concrete-Filled Steel Tubular Columns under Long-term Sustained Loads
    Yang, You-Fu
    ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (02) : 189 - 206
  • [39] Long-term behaviour of square concrete-filled steel tubular columns under axial service loads
    Kwon, S. -H.
    Kim, T. -H.
    Kim, Y. -Y.
    Kim, J. -K.
    MAGAZINE OF CONCRETE RESEARCH, 2007, 59 (01) : 53 - 68
  • [40] Study on concrete-filled stainless steel carbon steel tubular (CFSCT) stub columns under compression
    Chang, Xu
    Ru, Zhong Liang
    Zhou, Wei
    Zhang, Yong-Bin
    THIN-WALLED STRUCTURES, 2013, 63 : 125 - 133