Reliability of EMG power-spectrum and amplitude of the semitendinosus and biceps femoris muscles during ramp isometric contractions

被引:28
|
作者
Kellis, Eleftherios [1 ]
Katis, Athanasios [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Phys Educ & Sports Sci Serres, Lab Neuromuscular Control & Therapeut Exercise, Serres 62100, Greece
关键词
electromyography; surface electromyography; reliability; muscle moment; EMG-force; knee joint; ACL; knee stability; hamstrings; knee flexors;
D O I
10.1016/j.jelekin.2006.12.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Appropriate reliability is a necessary condition for the use of surface EMG for evaluation of hamstring muscle function in cases of knee joint pathologies or ligament injuries. The aim of the study was to investigate the test-retest reliability of power spectrum and amplitude of surface electromyographic (EMG) measurements of semitendinosus (ST) and biceps femoris (BF) during ramp isometric contractions. Eleven males performed maximum isometric contractions (MVC) of the knee flexors in two sessions, a week apart with simultaneous recording of surface EMG of the BF and ST. Intra class correlation (ICC) and standard error measurements (SEM) were applied to assess test-retest reliability of the averaged EMG (aEMG) and the median frequency (MF) over 10 levels of force, from 0% to 100% of the maximum. The ICC values ranged from 0.38 to 0.96 for the aEMG with SEM values reaching 11.37% of MVC. For the MF, the ICCs ranged from 0.44 to 0.98 (SEM range 4.49-18.19 Hz). In our set up, ramp contractions can be used to examine hamstring EMG patterns with acceptable reliability. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:351 / 358
页数:8
相关论文
共 50 条
  • [41] Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles
    Semmler, John G.
    Tucker, Kylie J.
    Allen, Trevor J.
    Proske, Uwe
    JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (03) : 979 - 989
  • [42] Reliability of near-infrared spectroscopy for measuring biceps brachii oxygenation during sustained and repeated isometric contractions
    Muthalib, Makii
    Millet, Guillaume Y.
    Quaresima, Valentina
    Nosaka, Kazunori
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [43] Extrapolation of time series of EMG power spectrum parameters in isometric endurance tests of trunk extensor muscles
    van Dieen, JH
    Heijblom, P
    Bunkens, H
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (01) : 35 - 44
  • [44] Normalization procedures using maximum voluntary isometric contractions for the serratus anterior and trapezius muscles during surface EMG analysis
    Ekstrom, RA
    Soderberg, GL
    Donatelli, RA
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2005, 15 (04) : 418 - 428
  • [45] RELATION BETWEEN EMG, STRENGTH AND MUSCULAR ELONGATION DURING VOLUNTARY ISOMETRIC CONTRACTIONS MEASURED ON HUMAN MASSETER AND TEMPORAL MUSCLES
    MANNS, AYCP
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1975, 25 : 53 - 53
  • [46] RANK ORDER OF PEAK AMPLITUDE OF EMG BETWEEN THE 3 MUSCLES OF TRICEPS SURAE DURING MAXIMUM ISOKINETIC CONTRACTIONS
    GERDLE, B
    FUGLMEYER, AR
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1988, 20 (02): : 89 - 92
  • [47] Test-retest reliability of muscle fiber conduction velocity and fractal dimension of surface EMG during isometric contractions
    Beretta-Piccoli, Matteo
    D'Antona, Giuseppe
    Zampella, Cristian
    Barbero, Marco
    Clijsen, Ron
    Cescon, Corrado
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (04) : 616 - 630
  • [48] Time-Dependent EMG Power Spectrum Parameters of Biceps Brachii during Cyclic Dynamic Contraction
    Thongpanja, S.
    Phinyomark, A.
    Phukpattaranont, P.
    Limsakul, C.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 233 - +
  • [49] Mechanomyographic amplitude and mean power frequency responses during isometric ramp vs. step muscle actions
    Ryan, Eric D.
    Beck, Travis W.
    Herda, Trent J.
    Hartman, Michael J.
    Stout, Jeffrey R.
    Housh, Terry J.
    Cramer, Joel T.
    JOURNAL OF NEUROSCIENCE METHODS, 2008, 168 (02) : 293 - 305
  • [50] Reliability of electromyography and peak torque during maximum voluntary concentric, isometric and eccentric contractions of quadriceps muscles in healthy subjects
    Carvalho, A.
    Abade, E.
    Carvalho, C.
    Sampaio, J.
    MEDICINA DELLO SPORT, 2014, 67 (02) : 185 - 193