Quality of ECG monitoring with a miniature ECG recorder

被引:7
|
作者
Janata, Andreas [1 ]
Lemmert, Miguel E. [2 ]
Russell, James K. [3 ]
Gehman, Stacy [3 ]
Fleischhackl, Roman [1 ]
Robak, Oliver [1 ]
Pernicka, Elisabeth [4 ]
Sterz, Fritz [1 ]
Gorgels, Anton P. M. [2 ]
机构
[1] Med Univ Vienna, Dept Emergency Med, Vienna, Austria
[2] Univ Limburg, Acad Hosp Maastricht, Dept Cardiol, Maastricht, Netherlands
[3] Philips Med Syst, Seattle, WA USA
[4] Med Univ Vienna, Core Unit Med Stat & Informat, Vienna, Austria
来源
关键词
arrhythmia monitoring; electrocardiogram; new technology;
D O I
10.1111/j.1540-8159.2008.01070.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Long-term monitoring of patients at risk of arrhythmias would benefit from a miniaturized device. This study evaluated the quality of electrocardiogram (ECG) signals recorded by a miniaturized ECG recorder. Methods: ECG data were concurrently recorded with an investigational device (Philips Medical Systems, Seattle, WA, USA) and a Holter recorder from patients with cardiac-related symptoms at the emergency department of a tertiary care university hospital. The device was attached in one of four locations (L1: below left clavicle, L2: midsternal, L3: below left breast, L4: left anterior axillary line in 5th intercostal space). Selected ECG strips were analyzed for atrial activity, QRS width, and basic rhythm by two physicians. Patients were divided into groups based on their number of strips (A 2-5, B 6-9, C 10-21) for descriptive presentation of the data. For statistical analyses, nonlinear mixed-effects models were used. Results: In 90 patients, 574 pairs of strips were analyzed. In L1 (n = 37), agreement between the device and the Holter recorder on presence of P wave was 58-80% in groups A-C and in L2 (n = 28):94-98%, L3 (n = 12):30-72%, and L4 (n = 13):0-70%; on PR interval in L1:58-80%, L2:94-98%, L3:30-62%, and L4:0-70%; on rhythm in L1:56-79%, L2:94-98%, L3:30-62%, and L4:0-70%; on QRS width in L1:86-100%, L2:88-98%, L3:100%, and L4:96-100%. The agreement of L2 in the parameters P wave, PR interval, and rhythm diagnosis was better than in the other locations (P < 0.01). Conclusions: A miniature ECG monitor provided accurate assessment of atrial beats and rhythm diagnosis at a midsternal location and of QRS width at all locations.
引用
收藏
页码:676 / 684
页数:9
相关论文
共 50 条
  • [31] Wireless ECG Monitoring System
    Simunic, Dina
    Tomac, Slaven
    Vrdoljak, Ivan
    2009 1ST INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATION, VEHICULAR TECHNOLOGY, INFORMATION THEORY AND AEROSPACE & ELECTRONIC SYSTEMS TECHNOLOGY, VOLS 1 AND 2, 2009, : 73 - +
  • [32] Wireless ECG monitoring by telephone
    Orlov, OI
    Drozdov, DV
    Doarn, CR
    Merrell, RC
    TELEMEDICINE JOURNAL AND E-HEALTH, 2001, 7 (01): : 33 - 38
  • [33] CONTINUOUS ECG MONITORING SYSTEMS
    DECKER, S
    NURSING CLINICS OF NORTH AMERICA, 1987, 22 (01) : 1 - 13
  • [34] ECG Monitoring System in Vehicles
    Wang, Ching-Sung
    Liu, Chien-Wei
    Huang, Yin-Cheng
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, : 253 - 254
  • [35] Remote ECG Monitoring by ECG247 Smart Heart Sensor
    Jortveit, Jarle
    Fensli, Rune
    INTERNATIONAL JOURNAL OF TELEMEDICINE AND APPLICATIONS, 2022, 2022
  • [36] SYSTEM FOR ECG MONITORING WITH A MINICOMPUTER
    NYGARDS, ME
    BLOMQVIS.P
    HULTING, J
    MATELL, G
    TORNKVIS.G
    WIGERTZ, O
    MEDICAL & BIOLOGICAL ENGINEERING, 1974, 12 (02): : 152 - 152
  • [37] RESPIRATION MONITORING BY USING ECG
    Rahman, Muhammad Towhidur
    Kadir, Muhammad Abdul
    Karim, A. H. M. Zadidul
    Al Mahmud, Md Abdullah
    2017 20TH INTERNATIONAL CONFERENCE OF COMPUTER AND INFORMATION TECHNOLOGY (ICCIT), 2017,
  • [38] EQUIPMENT INVOLVED IN ECG MONITORING
    VENN, PH
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1983, 29 (01): : 64 - 67
  • [39] System for monitoring ECG: cardioestudio
    Almeida, R.
    Gonzalez, R.
    Rodriguez, A.
    Rodriguez, G.
    IV LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING 2007, BIOENGINEERING SOLUTIONS FOR LATIN AMERICA HEALTH, VOLS 1 AND 2, 2008, 18 (1,2): : 175 - +
  • [40] ECG monitoring and analyses in mice
    Amende, I
    Dubach, JM
    Piskorski, K
    Morgan, JP
    Hampton, TG
    PHYSIOLOGICAL GENOMICS OF THE CRITICALLY ILL MOUSE, 2004, 16 : 89 - 100