Simulation of absorbed dose, in molecular therapy, by means of Monte Carlo method using free software GEANT4: GATE

被引:0
|
作者
Echevarria Torres, Waldo Jose [1 ]
Manso Nobrega, Weiner [2 ]
Gonzalez Gonzalez, Joaquin [3 ]
Fragoso Negrin, Jose Alejandro [4 ]
机构
[1] Univ Cent Las Villas, Santa Clara, Villa Clara, Cuba
[2] Inst Tecnol Aguascalientes, Aguascalientes, Aguascalientes, Mexico
[3] Inst Nacl Oncol & Radiobiol, Havana, La Habana, Cuba
[4] Inst Super Tecnol & Ciencias Aplicadas, Havana, La Habana, Cuba
来源
关键词
radiotherapy; radiation dosage; absorption; radiation; simulation technique; Monte Carlo Method;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: there is still no optimal way to determine the dose absorbed by tumors; this lack of knowledge is the reason why the final dose of treatment is unpredictable. For this reason, patients may be receiving doses greater than the minimum required for their correct diagnosis. Objective: to create a source code for an application project of the GATE program in the simulation of absorbed dose in molecular radiotherapy, by Monte Carlo method, for a Giap phantom. Methods: the simulation was carried out by the Montecarlo method from modeling the Giap phantom, using the GATE simulation platform. The results obtained were compared with the information reflected in the bibliography on standardized best practices. Results: a source code implemented in GATE was prepared for the determination of the absorbed dose in molecular radiotherapy. Non-uniform distribution of doses was obtained in a medium with uniform activity and an approximate 2% uncertainty (in correspondence with the values reported in the literature), the results allow to affirm that the dose simulation through the GATE platform is reliable, of little computational expense and highly recommended. Conclusions: it is advisable to use the GATE platform for the simulation of the calculation of the absorbed dose because it is fast, of low computational cost and reliable.
引用
收藏
页码:222 / 231
页数:10
相关论文
共 50 条
  • [21] A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5203 - 5219
  • [22] Voxel-based dose calculation of radionuclide imaging and therapy for preclinical studies using GEANT4 Monte Carlo simulation
    Liu, H.
    Geng, C.
    Tang, X.
    Tang, L.
    Li, X.
    Xu, P.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 317 - 322
  • [23] Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Particle Therapy Beam Nozzle
    Shin, J.
    Chun, J.
    Lee, H.
    Kim, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E264 - E265
  • [24] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [25] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117
  • [26] Implementation of the reverse/adjoint Monte Carlo method into Geant4
    Desorgher, L.
    Lei, F.
    Santin, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 247 - 257
  • [27] Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation
    Tran, H. N.
    Karamitros, M.
    Ivanchenko, V. N.
    Guatelli, S.
    McKinnon, S.
    Murakami, K.
    Sasaki, T.
    Okada, S.
    Bordage, M. C.
    Francis, Z.
    El Bitar, Z.
    Bernal, M. A.
    Shin, J. I.
    Lee, S. B.
    Barberet, Ph.
    Tran, T. T.
    Brown, J. M. C.
    Hao, T. V. Nhan
    Incerti, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 373 : 126 - 139
  • [28] Monte Carlo simulation of the Zeiss INTRABEAM with cylinder applicator using the GEANT4 precise dose calculation in the IORT
    Clausen, S.
    Schneider, F.
    Jahnke, L.
    Fleckenstein, J.
    Hesser, J.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 51 - 51
  • [29] RADIOTHERAPY MONTE CARLO DOSIMETRY USING GATE/GEANT4: VALIDATION STUDY IN ANTHROPOMORPHIC PHANTOM
    Perrot, Y.
    Breton, V.
    Donnarieix, D.
    Maigne, L.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S491 - S492
  • [30] Dosimetric Comparison of Radiation Therapy and Proton Therapy in Prostate Cancer Using the Monte Carlo Simulation Platform GEANT4
    Ismail Ghazi
    Zineb Sobhy
    Mustapha Krim
    Othmane Kaanouch
    Meriem Tantaoui
    Abdelkrim Kartouni
    Jamal Inchaouh
    Hamid Chakir
    Said Ouaskit
    Moscow University Physics Bulletin, 2021, 76 : 326 - 332