Automatic tube-current modulation in CT -: A comparison between different solutions

被引:23
|
作者
Althén, JN [1 ]
机构
[1] Linkoping Univ Hosp, Dept Radiat Phys, SE-58185 Linkoping, Sweden
关键词
D O I
10.1093/rpd/nch501
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, tube-current modulation systems on two different CT equipments have been evaluated: Care Dose from Siemens and Auto mA from GE Medical Systems. Care Dose modulates the tube current in the xy-plane during rotation whereas Auto mA modulates the tube currant in the z-direction. xy-Plane modulation was investigated by using an elliptic Polymethylmethacrylate phantom and a CTDI-ion chamber. To investigate modulation in the z-direction. an anthropomorphic dosimetry phantom (Atom) was used. Tests performed with and without tube-current modulation were compared with respect to absorbed dose and image quality. In the anthropomorphic phantom measurements, the dose savings were 15% using Care Dose and the photon starvation artefacts were negligible. Using Auto mA the absorbed dose depends on the chosen noise level. Image noise becomes more constant throughout the patient but photon starvation artefacts remain. We conclude that the two tube-current modulation techniques show different dose advantages, and image quality artefacts.
引用
收藏
页码:308 / 312
页数:5
相关论文
共 50 条
  • [21] Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study
    Rizzo, SMR
    Kalra, MK
    Maher, MM
    Blake, MA
    Toth, TL
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 491 - 496
  • [22] Image quality and dose trends in tube-current modulated multi-detector CT imaging
    Fisher, R.
    Hintenlang, D.
    Arreola, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2344 - 2344
  • [23] The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging
    Sabah Servaes
    Xiaowei Zhu
    Pediatric Radiology, 2013, 43 : 1287 - 1294
  • [24] Achieving Consistent Tube Output Curves On CT Scanners with Different Implementations of Tube Current Modulation
    Ferrero, A.
    Favazza, C.
    Glazebrook, K.
    Adkins, M.
    Yu, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E189 - E189
  • [25] A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT
    Merzan, D.
    Bujila, R.
    Nowik, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [26] The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging
    Servaes, Sabah
    Zhu, Xiaowei
    PEDIATRIC RADIOLOGY, 2013, 43 (10) : 1287 - 1294
  • [27] Evaluation of automatic tube current modulation in a CT scanner using a customised homogeneous phantom
    Hishaam, Urshella
    Jeyasugiththan, Jeyasingam
    Viswakula, Sameera
    Satharasinghe, D. M.
    Amalaraj, T.
    Costa, M.
    Kumarihami, A. M. C.
    Pallewatte, Aruna
    Peterson, Steve
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [28] Real-Time Dose Measurements of Automatic Tube Current Modulation in Multislice CT
    Tsai, H. Y.
    Chang, Y. C.
    Tyan, Y. S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] Quantitative assessment of image noise and streak artifact on CT image: Comparison of z-axis automatic tube current modulation technique with fixed tube current technique
    Imai, Kuniharu
    Ikeda, Mitsuru
    Enchi, Yukihiro
    Niimi, Takanaga
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (05) : 353 - 358
  • [30] A Phantom Evaluation of the Use of Ct Automatic Tube Current Modulation with Low Tube Potentials for Iodinated Contrast Studies
    Sookpeng, Supawitoo
    Martin, Colin J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (03) : 188 - 195