Chest radiography is a poor predictor of left ventricular lead position in patients undergoing cardiac resynchronization therapy: comparison with multidetector computed tomography

被引:15
|
作者
Rickard, John [1 ]
Ingelmo, Christopher [1 ]
Sraow, Dan [1 ]
Wilkoff, Bruce L. [1 ]
Grimm, Richard A. [1 ]
Schoenhagen, Paul [1 ]
Tchou, Patrick J. [1 ]
Desai, Milind Y. [1 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Tomsich Dept Cardiovasc Med, Cleveland, OH 44195 USA
关键词
Lead position; Left ventricular lead position; Cardiac resynchronization therapy; Chest X-ray; CHRONIC HEART-FAILURE; ECHOCARDIOGRAPHY; IMPACT; OUTCOMES; SITES;
D O I
10.1007/s10840-011-9586-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optimal left ventricular (LV) lead position is thought to be a major predictor of response in patients undergoing cardiac resynchronization therapy (CRT). While the post-implant posterior-anterior (PA) and lateral chest X-ray (CXR) is commonly used to determine the position of the LV lead, the accuracy to which the CXR can correctly localize the LV lead is unknown. We collected data on 47 consecutive patients (mean age 64 years, 60% men and LV ejection fraction 23%, 49% ischemic cardiomyopathy) that underwent CRT between 2004 and 2007, who had both a post-implant CXR as well as a contrast-enhanced multi-detector computed tomography (MDCT) of the chest for any reason. The positions of the LV lead on CXR and MDCT were interpreted in a blinded fashion, independent of each other. The accuracy of the CXR in localizing various LV lead positions, with MDCT as the gold standard, was recorded. On CXR, the LV lead tip position was as follows: basal (4%), mid-ventricular (66%), and apical (30%) and anterior (2%), lateral (34%), and posterior (64%). On MDCT, the LV tip position was: basal (28%), mid-ventricular (60%), and apical (13%) and anterior (13%), lateral (19%), and posterior (68%). Compared to the MDCT gold standard, the percentage of LV lead positions the CXR correctly classified correctly were: 100% basal, 39% mid-ventricular, and 29% apical and 0% anterior, 12% lateral, and 77% posterior. Taking both PA and lateral views into consideration, the LV lead position was misclassified by CXR in 62% cases. Using MDCT as a gold standard, the routine post-implant CXR performs very modestly in terms of accurate LV lead positioning.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [41] Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy
    Jeong, Dong Seop
    Park, Pyo Won
    Lee, Young Tak
    Park, Seung-Jung
    Kim, June Soo
    On, Young Keun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2012, 27 (12) : 1595 - 1597
  • [42] Unusual failure of left ventricular lead implantation diagnosed by multidetector computed tomography
    Da Costa, Antoine
    Gate-Martinet, Alexie
    Nadrouss, Abdallah
    Isaaz, Karl
    EUROPACE, 2012, 14 (05): : 770 - 771
  • [43] Relationship of Baseline Right Ventricular Function, Left Ventricular Lead Position and Survival Following Cardiac Resynchronization Therapy
    Kydd, Anna C.
    Watson, Will
    Khan, Fakhar Z.
    Virdee, Munmohan S.
    Dutka, David P.
    CIRCULATION, 2012, 126 (21)
  • [44] VV Optimization May Partially Offset the Effects of a Suboptimal Left Ventricular Lead Position in Patients Undergoing Cardiac Resynchronization Therapy: An Acute Hemodynamic Study
    Khan, Fakhar
    Virdee, Munmohan S.
    Read, Philip A.
    Fynn, Simon P.
    Dutka, David P.
    CIRCULATION, 2009, 120 (18) : S787 - S788
  • [45] Characterization of the Suitability of Coronary Venous Anatomy for Targeting Left Ventricular Lead Placement in Patients Undergoing Cardiac Resynchronization Therapy
    Khan, Fakhar Z.
    Virdee, Munmohan S.
    O'Halloran, Denis
    Salahshouri, Pegah
    Read, Phil
    Watson, Timothy
    Fynn, Simon P.
    Dutka, David P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A124 - A124
  • [46] Characterization of the suitability of coronary venous anatomy for targeting left ventricular lead placement in patients undergoing cardiac resynchronization therapy
    Khan, Fakhar Zaman
    Virdee, Munmohan Singh
    Gopalan, Deepa
    Rudd, James
    Watson, Timothy
    Fynn, Simon Patrick
    Dutka, David Paul
    EUROPACE, 2009, 11 (11): : 1491 - 1495
  • [47] Lateral left ventricular lead position is superior to posterior position in long-term outcome of patients underwent cardiac resynchronization therapy
    Behon, A.
    Schwertner, W. R.
    Merkel, E. D.
    Kovacs, A.
    Lakatos, B. K.
    Zima, E.
    Geller, L.
    Kutyifa, V
    Kosztin, A.
    Merkely, B.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1086 - 1086
  • [48] Assessment of global left ventricular function - Comparison of cardiac multidetector-row computed tomography with angiocardiography
    Hundt, W
    Siebert, K
    Wintersperger, BJ
    Becker, CR
    Knez, A
    Reiser, MF
    Rubin, GD
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (03) : 373 - 381
  • [49] Assessment of global left ventricular function: Comparison of multidetector computed tomography with left ventriculography
    Hundt, W
    Siebert, K
    Becker, C
    Knez, A
    Rubin, GD
    Reiser, MF
    RADIOLOGY, 2002, 225 : 388 - 388
  • [50] Outcome of Patients Treated by Cardiac Resynchronization Therapy Using a Quadripolar Left Ventricular Lead
    Bencardino, Gianluigi
    Di Monaco, Antonio
    Russo, Eleonora
    Colizzi, Cristian
    Perna, Francesco
    Pelargonio, Gemma
    Narducci, Maria Lucia
    Gabrielli, Francesca Augusta
    Lanza, Gaetano Antonio
    Rebuzzi, Antonio Giuseppe
    Crea, Filippo