How Accurately Can Soft Tissue Balance Be Determined in Total Knee Arthroplasty?

被引:47
|
作者
MacDessi, Samuel J. [1 ]
Gharaibeh, Monther A. [1 ]
Harris, Ian A. [2 ]
机构
[1] St George Private Hosp, Sydney Knee Specialists, Kogarah, NSW, Australia
[2] Univ New South Wales, South Western Sydney Clin Sch, Liverpool, NSW, Australia
来源
JOURNAL OF ARTHROPLASTY | 2019年 / 34卷 / 02期
关键词
knee; arthroplasty; sensor; balance; ligaments; EARLY OUTCOMES; REPLACEMENT; ALIGNMENT; FAILURE;
D O I
10.1016/j.arth.2018.10.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Soft tissue balance is believed to be a major determinant of improved outcomes in total knee arthroplasty (TKA). We conducted this study to assess the accuracy of surgeon-defined assessment (SDA) of knee balance compared to pressure sensor data. We also assessed for any association between experience (learning curve) and accuracy of SDA. Methods: A total of 308 patients undergoing 322 mechanically aligned TKA were prospectively analyzed. Femoral and tibial trial implants were inserted before performing knee balancing. We compared the surgeon determination on knee balance at 10 degrees, 45 degrees, and 90 degrees of flexion to sensor data at the same flexion angles. Results: Accuracy of SDA was 63%, 57.5%, and 63.8% at 10 degrees, 45 degrees, and 90 degrees, respectively, when compared to sensor data. SDA had an overall sensitivity of 81% and specificity of 37.7%. Capacity to determine an unbalanced knee worsened at higher knee flexion angles with SDA test specificity of 53.5%, 34.8%, and 24.8% at 10 degrees, 45 degrees, and 90 degrees, respectively (P = .0004 at 10 degrees vs 45 degrees, P < .0001 at 10 degrees vs 90 degrees). Cohen's kappa coefficient was 0.29 at 10 degrees indicating fair agreement, and 0.14 and 0.12 at 45 degrees and 90 degrees, respectively, indicating poor agreement. The use of sensor had no time-based learning effect on capacity to determine knee balance. Conclusion: SDA is a poor predictor of the true soft tissue balance when compared to sensor data, particularly in assessing whether a knee is unbalanced. In addition, increased use of sensors did not improve surgeon capacity to determine knee balance. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:290 / +
页数:6
相关论文
共 50 条
  • [11] Soft Tissue Balance Changes Depending on Joint Distraction Force in Total Knee Arthroplasty
    Nagai, Kanto
    Muratsu, Hirotsugu
    Matsumoto, Tomoyuki
    Miya, Hidetoshi
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03): : 520 - 524
  • [12] An electronic force sensor accurately detects increased but not decreased soft tissue tension in total knee arthroplasty
    Kuriyama, Shinichi
    Nishitani, Kohei
    Nakamura, Shinichiro
    Matsuda, Shuichi
    KNEE, 2023, 42 : 210 - 219
  • [13] Soft-tissue tension total knee arthroplasty
    Asano, H
    Hoshino, A
    Wilton, TJ
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 558 - 561
  • [14] Stiffness of soft tissue complex in total knee arthroplasty
    Hiroshi Asano
    Takeshi Muneta
    Akiho Hoshino
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 51 - 55
  • [15] Soft Tissue Issues and Considerations in Total Knee Arthroplasty
    Padilla, Jorge A.
    Teo, Greg
    Vigdorchik, Jonathan M.
    Schwarzkopf, Ran
    Long, William J.
    TECHNIQUES IN ORTHOPAEDICS, 2019, 34 (03) : 210 - 215
  • [16] Accuracy of soft tissue balancing in total knee arthroplasty
    Griffin, FM
    Insall, JN
    Scuderi, GR
    JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 970 - 973
  • [17] Dynamic Soft Tissue Balancing in Total Knee Arthroplasty
    Roche, Martin
    Elson, Leah
    Anderson, Christopher
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2014, 45 (02) : 157 - +
  • [18] Soft tissue balancing in total condylar knee arthroplasty
    Trepte, CT
    Pfanzelt, K
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 70 - 73
  • [19] Stiffness of soft tissue complex in total knee arthroplasty
    Asano, Hiroshi
    Muneta, Takeshi
    Hoshino, Akiho
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (01) : 51 - 55
  • [20] Soft Tissue Balance Measurement in Posterior-Stabilized Total Knee Arthroplasty With a Navigation System
    Matsumoto, Tomoyuki
    Muratsu, Hirotsugu
    Tsumura, Nobuhiro
    Mizuno, Kiyonori
    Kurosaka, Masahiro
    Kuroda, Ryosuke
    JOURNAL OF ARTHROPLASTY, 2009, 24 (03): : 358 - 364