Albumin Dialysis in Artificial Liver Support Systems: Open-Loop or Closed-Loop Dialysis Mode?

被引:3
|
作者
Pei, Yingying [1 ,2 ,3 ]
Sun, Yize [1 ]
Sun, Sijie [4 ]
Gao, Dayong [2 ,5 ]
Ding, Weiping [2 ,3 ]
机构
[1] Donghua Univ, Dept Mech Engn, Shanghai, Peoples R China
[2] Univ Sci & Technol China, Ctr Biomed Engn, Hefei 230027, Anhui, Peoples R China
[3] Univ Sci & Technol China, Dept Elect Sci & Technol, Hefei 230027, Anhui, Peoples R China
[4] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
[5] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
基金
高等学校博士学科点专项科研基金;
关键词
albumin dialysis; artificial liver support system; protein-bound toxin; mass transfer; bilirubin; FAILURE; ULTRAFILTRATION; TRANSPLANTATION; HEMOFILTRATION; FILTRATION; ADSORPTION; AFFINITY; BINDING; TOXINS; MARS;
D O I
10.1097/MAT.0000000000000198
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In artificial liver support systems, the open-loop albumin dialysis mode (OLM) is usually used to remove protein-bound toxins from the blood of patients with liver failure. However, there is still interest in the closed-loop albumin dialysis mode (CLM) because this mode may enable not only the regeneration and reuse of albumin but also the miniaturization of artificial liver systems. In this article, we compared the two modes under a fixed amount of albumin in dialysate experimentally and theoretically. The results show that according to the detoxification efficiency in the 3 hour dialysis for removing albumin-bound bilirubin, CLM is better than OLM. The usage efficiency of albumin in CLM is also higher. Moreover, the advantage of CLM is more significant when the concentration of bilirubin in blood is lower. Under a given amount of albumin in dialysate, if the concentration of bilirubin in blood is high, one may further increase the performance of CLM by means of increasing the flow rate of the albumin dialysate or using the highly concentrated albumin dialysate.
引用
收藏
页码:324 / 331
页数:8
相关论文
共 50 条
  • [31] OPTIMAL OPEN-LOOP AND CLOSED-LOOP CONTROL OF SINGULARLY PERTURBED LINEAR-SYSTEMS
    WILDE, RR
    KOKOTOVIC, PV
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1973, AC18 (06) : 616 - 626
  • [32] CONDITIONS FOR PARAMETRIC IDENTIFIABILITY OF CONTROLLABLE OBJECTS IN OPEN-LOOP AND CLOSED-LOOP AUTOMATIC SYSTEMS
    PETROV, BN
    TERYAYEV, YD
    SHAMRIKOV, BM
    ENGINEERING CYBERNETICS, 1977, 15 (02): : 137 - 152
  • [33] CLOSED-LOOP IDENTIFICATION OF THE BAROREFLEX OPEN-LOOP TRANSFER-FUNCTION
    KAWADA, T
    IKEDA, Y
    MIYANO, H
    MATSUURA, W
    SATO, T
    SUNAGAWA, K
    CIRCULATION, 1995, 92 (08) : 3514 - 3514
  • [34] CALORIC IRRIGATORS - AIR, OPEN-LOOP WATER AND CLOSED-LOOP WATER
    ANDERSON, S
    BRITISH JOURNAL OF AUDIOLOGY, 1995, 29 (02): : 117 - 128
  • [35] Autonomous Drift Cornering with Mixed Open-loop and Closed-loop Control
    Zhang, F.
    Gonzales, J.
    Li, K.
    Borrelli, F.
    IFAC PAPERSONLINE, 2017, 50 (01): : 1916 - 1922
  • [36] Effects of open-loop and closed-loop control on subsonic cavity flows
    Little, J.
    Debiasi, M.
    Caraballo, E.
    Samimy, M.
    PHYSICS OF FLUIDS, 2007, 19 (06)
  • [37] Reinforcement learning fbr mixed open-loop and closed-loop control
    Hansen, EA
    Barto, AG
    Zilberstein, S
    ADVANCES IN NEURAL INFORMATION PROCESSING SYSTEMS 9: PROCEEDINGS OF THE 1996 CONFERENCE, 1997, 9 : 1026 - 1032
  • [38] Analysis of Open-loop and Closed-loop Planning for Aircraft Collision Avoidance
    Chryssanthacopoulos, James P.
    Kochenderfer, Mykel J.
    2011 14TH INTERNATIONAL IEEE CONFERENCE ON INTELLIGENT TRANSPORTATION SYSTEMS (ITSC), 2011, : 212 - 217
  • [39] Comparisons between Quantum Open-Loop Control and Closed-Loop Control
    Bo, Qi
    Lei, Guo
    PROCEEDINGS OF THE 27TH CHINESE CONTROL CONFERENCE, VOL 7, 2008, : 393 - 397
  • [40] Neocortical electrical stimulation for epilepsy: Closed-loop versus open-loop
    Vassileva, Albena
    van Blooijs, Dorien
    Leijten, Frans
    Huiskamp, Geertjan
    EPILEPSY RESEARCH, 2018, 141 : 95 - 101