Geiger-mode APD Camera System for Single Photon 3-D LADAR Imaging

被引:28
|
作者
Entwistle, Mark [1 ]
Itzler, Mark A. [1 ]
Chen, Jim [1 ]
Owens, Mark [1 ]
Patel, Ketan [1 ]
Jiang, Xudong [1 ]
Slomkowski, Krystyna [1 ]
Rangwala, Sabbir [1 ]
机构
[1] Princeton Lightwave Inc, Cranbury, NJ 08512 USA
来源
关键词
avalanche photodiodes; Geiger mode; single photon camera; photon counting; LADAR; 3-D imaging; focal plane arrays; InGaAsP; AVALANCHE; DIODES;
D O I
10.1117/12.921004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The unparalleled sensitivity of 3D LADAR imaging sensors based on single photon detection provides substantial benefits for imaging at long stand-off distances and minimizing laser pulse energy requirements. To obtain 3D LADAR images with single photon sensitivity, we have demonstrated focal plane arrays (FPAs) based on InGaAsP Geiger-mode avalanche photodiodes (GmAPDs) optimized for use at either 1.06 mu m or 1.55 mu m. These state-of-the-art FPAs exhibit excellent pixel-level performance and the capability for 100% pixel yield on a 32 x 32 format. To realize the full potential of these FPAs, we have recently developed an integrated camera system providing turnkey operation based on FPGA control. This system implementation enables the extremely high frame-rate capability of the GmAPD FPA, and frame rates in excess of 250 kHz (for 0.4 mu s range gates) can be accommodated using an industry-standard CameraLink interface in full configuration. Real-time data streaming for continuous acquisition of 2 mu s range gate point cloud data with 13-bit time-stamp resolution at 186 kHz frame rates has been established using multiple solid-state storage drives. Range gate durations spanning 4 ns to 10 mu s provide broad operational flexibility. The camera also provides real-time signal processing in the form of multi-frame gray-scale contrast images and single-frame time-stamp histograms, and automated bias control has been implemented to maintain a constant photon detection efficiency in the presence of ambient temperature changes. A comprehensive graphical user interface has been developed to provide complete camera control using a simple serial command set, and this command set supports highly flexible end-user customization.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Measurements of the photon detection efficiency done for Geiger-mode avalanche photodiodes (G-APD)
    Gentile, S.
    Meddi, F.
    Kuznetsova, E.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 64 - 69
  • [22] Time-resolved photon counting system based on a Geiger-mode InGaAs/InP APD and a solid immersion lens
    Vickers, JS
    Ispasoiu, R
    Cotton, D
    Frank, J
    Lee, B
    Kasapi, S
    2003 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2003, : 600 - 601
  • [23] Smart three-dimensional imaging ladar using two Geiger-mode avalanche photodiodes
    Kong, Hong Jin
    Kim, Tae Hoon
    Jo, Sung Eun
    Oh, Min Seok
    OPTICS EXPRESS, 2011, 19 (20): : 19323 - 19329
  • [24] Geiger-mode avalanche photodiode focal plane arrays for three-dimensional imaging LADAR
    Itzler, Mark A.
    Entwistle, Mark
    Owens, Mark
    Patel, Ketan
    Jiang, Xudong
    Slomkowski, Krystyna
    Rangwala, Sabbir
    Zalud, Peter F.
    Senko, Tom
    Tower, John
    Ferraro, Joseph
    INFRARED REMOTE SENSING AND INSTRUMENTATION XVIII, 2010, 7808
  • [25] Experimental Evaluation of Penetration Capabilities of a Geiger-mode APD Array Laser Radar System
    Jonsson, Per
    Tulldahl, Michael
    Hedborg, Julia
    Henriksson, Markus
    Sjogyist, Lars
    ELECTRO-OPTICAL REMOTE SENSING XI, 2017, 10434
  • [26] Silicon Geiger-mode avalanche photodiode arrays for photon-starved imaging
    Aull, Brian F.
    ADVANCED PHOTON COUNTING TECHNIQUES IX, 2015, 9492
  • [27] Geiger-mode focal plane arrays enable SWIR 3D imaging
    Itzler, Mark
    Entwistle, Mark
    LASER FOCUS WORLD, 2011, 47 (03): : 71 - 74
  • [28] Ultra-high sensitivity APD based 3D LADAR sensors: linear mode photon counting LADAR camera for the Ultra-Sensitive Detector program
    Asbrock, J.
    Bailey, S.
    Baley, D.
    Boisvert, J.
    Chapman, G.
    Crawford, G.
    De Lyon, T.
    Drafahl, B.
    Edwards, J.
    Herrin, E.
    Hoyt, C.
    Jack, M.
    Kvaas, R.
    Liu, K.
    McKeag, W.
    Rajavel, R.
    Randall, V.
    Rengarajan, S.
    Riker, J.
    INFRARED TECHNOLOGY AND APPLICATIONS XXXIV, PTS 1 AND 2, 2008, 6940
  • [29] Improvement of SNR by temporal filtering method in LADAR system using two Geiger-mode avalanche photodiodes
    Kim, Tae Hoon
    Kong, Hong Jin
    Jo, Sung Eun
    LASER RADAR TECHNOLOGY AND APPLICATIONS XVII, 2012, 8379
  • [30] An ultrafast Geiger-mode single photon avalanche diode in 0.18 μm CMOS technology
    Finkelstein, Hod
    Hsu, Mark J.
    Esener, Sadik
    ADVANCED PHOTON COUNTING TECHNIQUES, 2006, 6372