Evaluation of various phenotypic methods with genotypic screening for detection of methicillin-resistant Staphylococcus aureus

被引:8
|
作者
Loganathan, Archana [1 ]
Manohar, Prasanth [1 ]
Eniyan, Kandasamy [1 ]
Jayaraj, Rama [2 ]
Nachimuthu, Ramesh [1 ]
机构
[1] Vellore Inst Technol, Sch Biosci & Technol, Dept Biomed Sci, Vellore, Tamil Nadu, India
[2] Charles Darwin Univ, Coll Hlth & Human Sci, Dept Clin Sci, Darwin, NT, Australia
关键词
cefoxitin; heterogenous population; Staphylococcus aureus; MRSA; PREVALENCE; HOMOLOG;
D O I
10.1515/abm-2019-0065
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Staphylococcus aureus is one of the common opportunistic gram-positive pathogens which are often associated with nosocomial infections. Detection of methicillin-resistant S. aureus (MRSA) has become complicated due to the complex phenotypic and genomic pattern. Objective: To evaluate the sensitivity and specificity pattern of various phenotypic methods used in screening mec genes harboring MRSA. Methods: Clinical isolates of S. aureus were collected from diagnostic centers in Tamil Nadu. Phenotypic identification methods such as Minimal Inhibitory Concentration for oxacillin, oxacillin screen agar (OSA), oxacillin disk diffusion, and cefoxitin disk diffusion (CFD) tests were compared. The clinical isolates were classified into MRSA and methicillin-susceptible S. aureus (MSSA) based on the polymerase chain reaction (PCR) amplification of the mecA gene. Result: Out of 50 S. aureus, 21 were found to be MRSA based on the presence of the mecA gene. All 21 mecA-positive isolates were found to be resistant through minimum inhibitory concentration (MIC) and CFD test, having a sensitivity of 100% and specificity of 52% and 62%, respectively. OSA and oxacillin disk tests were found to have a sensitivity of 86% and specificity of 48% and 52%, respectively. Conclusion: The combination of two phenotypic methods, CFD and oxacillin MIC, can be used for the detection of MRSA in clinical laboratories.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 50 条
  • [41] The use of molecular methods for the detection and identification of methicillin-resistant Staphylococcus aureus
    Hirvonen, Jari J.
    BIOMARKERS IN MEDICINE, 2014, 8 (09) : 1115 - 1125
  • [42] Detection of Methicillin-Resistant Staphylococcus aureus Infections Using Molecular Methods
    Tenover, Fred C.
    Tickler, Isabella A.
    ANTIBIOTICS-BASEL, 2022, 11 (02):
  • [43] Assessment of three rapid methods for the detection of methicillin-resistant Staphylococcus aureus
    Soares, MJ
    Soares, C
    Mendes, AC
    Guimaraes, ML
    Cabeda, JM
    Amorim, JM
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2004, 22 (07): : 390 - 391
  • [44] COMPARISON OF FOUR DIAGNOSTIC METHODS FOR DETECTION OF METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS
    Hasanzadeh, Sepideh
    Pourmand, Mohamadreza
    Mashhade, Rahil
    Dehbashi, Sanaz
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2014, 43 : 70 - 70
  • [45] Evaluation of aminoglycoside- and methicillin-resistant Staphylococcus aureus: phenotypic and genotypic insights from clinical specimens in Ardabil, Iran
    Hushyar, Samira
    Doghaheh, Hadi Peeri
    Arzanlou, Mohsen
    BMC INFECTIOUS DISEASES, 2025, 25 (01)
  • [46] EVALUATION OF ELECTROPHORETIC METHODS FOR TYPING METHICILLIN-RESISTANT STAPHYLOCOCCUS-AUREUS
    GASTON, MA
    DUFF, PS
    NAIDOO, J
    ELLIS, K
    ROBERTS, JIS
    RICHARDSON, JF
    MARPLES, RR
    COOKE, EM
    JOURNAL OF MEDICAL MICROBIOLOGY, 1988, 26 (03) : 189 - 197
  • [47] Methicillin-resistant Staphylococcus aureus staff screening and decolonisation
    Johnston, K. D.
    ANAESTHESIA, 2010, 65 (04) : 409 - 409
  • [48] Screening for methicillin-resistant Staphylococcus aureus in a nursing home
    Drinka, PJ
    Stemper, ME
    Gauerke, CD
    Miller, JE
    Reed, KD
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2004, 25 (02): : 95 - 96
  • [49] Usefulness of Weekly Methicillin-Resistant Staphylococcus aureus Screening
    Rymzhanova, Raouchan
    Thouverez, Michelle
    Talon, Daniel
    Bertrand, Xavier
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (11): : 1113 - 1115
  • [50] Screening for Methicillin-Resistant Staphylococcus aureus: Reliability and Accuracy
    Bhat, Sunil V.
    Bhanot, Nitin
    Chan-Tompkins, Noreen H.
    Sahud, Andrew G.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (01): : 97 - 98