Silver-manganese nanocomposite modified screen-printed carbon electrode in the fabrication of an electrochemical, disposable biosensor strip for cystic fibrosis

被引:9
|
作者
Kumar, P. Arun [1 ,2 ]
Pradeep, Aarathi [1 ,2 ]
Nair, Bipin Kumar G. [1 ,3 ,4 ]
Babu, T. G. Satheesh [1 ,2 ,4 ]
Suneesh, Punathil Vasu [1 ,2 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Biosensor Res Lab, Amrita Sch Engn, Coimbatore, Tamil Nadu, India
[2] Amrita Vishwa Vidyapeetham, Dept Sci, Amrita Sch Phys Sci, Coimbatore, Tamil Nadu, India
[3] Amrita Vishwa Vidyapeetham, Amrita Sch Biotechnol, Amritapuri, India
[4] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Amrita Biomed Engn Ctr, Coimbatore, Tamil Nadu, India
关键词
Silver-manganese nanocomposite; Screen printing; Electrochemical chloride sensor; Biosensor strip; Sweat chloride; Cystic fibrosis; CHLORIDE; SENSOR; NANOPARTICLES; QUANTIFICATION; OXIDE;
D O I
10.1007/s00604-022-05431-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A silver-manganese nanocomposite was successfully prepared by the urea hydrolysis method and used to detect chloride ions in sweat electrochemically. The synthesis involves the reaction of manganese sulphate, silver nitrate, and urea at 100 degrees C for 24 h. The crystalline nature of the particle was studied by diffraction analysis and found to be mixed-phase oxides of manganese alongside the oxides of silver. Morphological studies revealed the presence of quasi-prism-like structures, which is characteristic of beta-MnO2. A disposable sensor was fabricated by screen-printing the catalyst and used for the electrochemical detection of chloride ions in sweat. The sensor exhibited good selectivity, a sensitivity of 22.93 +/- 0.64 mu A mM(-1) cm(-2) in solution and 3010 +/- 60 mu A (log mM) (-1) cm(-2) for the fabricated sensor strip with a detection range from 5 mM up to 200 mM. The detection limit is 207 +/- 7 mu M (S/N = 3) in solution and 17 +/- 6 mu M for the fabricated sensor strip. The relative standard deviation (RSD) of sensor response is 2.38%. A prototype of the biosensor strip was fabricated and validated using real samples. This brings the possibility of developing a real-time biosensor strip for cystic fibrosis in point-of-care testing applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Disposable screen-printed antimony film electrode modified with carbon nanotubes/ionic liquid for electrochemical stripping measurement
    Niu, Xiangheng
    Zhao, Hongli
    Lan, Minbo
    ELECTROCHIMICA ACTA, 2011, 56 (27) : 9921 - 9925
  • [22] Sensitive Electrochemical Detection of Creatinine at Disposable Screen-Printed Carbon Electrode Mixed with Ferrocenemethanol
    Chen, Ping
    Peng, Yong
    He, Min
    Yan, Xin-Chuang
    Zhang, Yuan
    Liu, You-Nian
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 8931 - 8939
  • [23] Disposable Screen-printed Bismuth Electrode Modified with Multi-walled Carbon Nanotubes for Electrochemical Stripping Measurements
    Niu, Xiangheng
    Zhao, Hongli
    Lan, Minbo
    ANALYTICAL SCIENCES, 2011, 27 (12) : 1237 - 1241
  • [24] Disposable L-lactate biosensor based on a screen-printed carbon electrode enhanced by graphene
    Tu, Dandan
    He, Yu
    Rong, Yuanzhen
    Wang, You
    Li, Guang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (04)
  • [26] Modification of Disposable Screen-Printed Carbon Electrode Surfaces with Conductive Electrospun Nanofibers for Biosensor Applications
    Ekabutr, Pongpol
    Chailapakul, Orawan
    Supaphol, Pitt
    JOURNAL OF APPLIED POLYMER SCIENCE, 2013, 130 (06) : 3885 - 3893
  • [27] Ultrasensitive cholesterol biosensor based on enzymatic silver deposition on gold nanoparticles modified screen-printed carbon electrode
    Huang, Yong
    Cui, Lijie
    Xue, Yewei
    Zhang, Songbai
    Zhu, Nixuan
    Liang, Jintao
    Li, Guiyin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 77 : 1 - 8
  • [28] Electrochemical detection of blood alcohol concentration using a disposable biosensor based on screen-printed electrode modified with Nafion and gold nanoparticles
    Luo, Peng
    Xie, Guoming
    Liu, Yi
    Xu, Huajian
    Deng, Shixiong
    Song, Fangzhou
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (11) : 1641 - 1647
  • [29] Fabrication and electrochemical characterization of polydopamine redox polymer modified screen-printed carbon electrode for the detection of guanine
    Kanyong, Prosper
    Rawlinson, Sean
    Davis, James
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 : 528 - 534
  • [30] Modified screen-printed Electrode as Electrochemical Detector for Noscapine
    Aflatoonian, Mohammad Reza
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Behnaz
    Jafari, Maedeh
    Zhang, Kaiqiang
    Quyet Van Le
    Cha, Joo Hwan
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8612 - 8621