Evaluation of Conjunctival Graft Thickness after Pterygium Surgery by Anterior Segment Optical Coherence Tomography

被引:26
|
作者
Kheirkhah, Ahmad [1 ]
Adelpour, Mohsen [1 ]
Nikdel, Mojgan [1 ]
Ghaffari, Reza [1 ]
Ghassemi, Hamed [1 ]
Hashemi, Hassan [1 ]
机构
[1] Univ Tehran Med Sci, Farabi Eye Hosp, Eye Res Ctr, Tehran, Iran
关键词
Anterior segment optical coherence tomography; Conjunctival graft; Conjunctival thickness; Pterygium; VIVO CONFOCAL MICROSCOPY; FIBRIN GLUE; AUTOGRAFT; TRANSPLANTATION; TRABECULECTOMY; LIMBAL;
D O I
10.3109/02713683.2011.587937
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To evaluate changes in thickness of the conjunctival graft after pterygium surgery by anterior segment optical coherence tomography (AS-OCT). Materials and Methods: Eleven eyes of 11 patients with primary nasal pterygium underwent excision followed by free conjunctival autograft. Imaging with AS-OCT was performed at 1 week, 1 month and 3 months after surgery to measure thickness of the conjunctival graft at 1, 2 and 3 mm posterior to the scleral spur. As the control, thickness of the normal bulbar conjunctival epithelium in the temporal area was also measured at the same locations. Results: Average thickness of the graft decreased from 458 +/- 171 mu m at 1 week after surgery to 306 +/- 64 mu m at 1 month (p < 0.0001). Although the graft thickness decreased to 291 +/- 124 mu m at 3 months postoperatively, the difference between 1-month and 3-month values was not statistically significant (p = 0.94). Average thickness of the normal conjunctival epithelium was 58 +/- 13 mu m, 60 +/- 19 mu m and 61 +/- 12 mu m at 1 week, 1 month and 3 months after surgery, respectively, with no statistically significant difference. Graft thickness was significantly greater than thickness of the normal conjunctival epithelium at various time points (p < 0.05). Conclusion: Evaluation by AS-OCT showed that there was significant thickening of the conjunctival graft at 1 week after pterygium surgery which continued to decrease up to 3 months. Quantitative data by AS-OCT allows accurate evaluation of the conjunctival changes over time.
引用
收藏
页码:782 / 786
页数:5
相关论文
共 50 条
  • [21] Assessment of conjunctival autograft reperfusion after pterygium surgery by optical coherence tomography angiography (OCT-A)
    Masoumi, Ahmad
    Esfandiari, Amirreza
    Khalili, Atefeh
    Latifi, Golshan
    Ghanbari, Hamidreza
    Jafari, Behzad
    Montazeriani, Zahra
    Rahimi, Masoud
    Ghafarian, Sadegh
    MICROVASCULAR RESEARCH, 2025, 157
  • [22] Morphometric evaluation and measurements of primary pterygium by anterior segment optical coherence tomography and its relation with astigmatism
    Raj, Anuradha
    Dhasmana, Renu
    Bahadur, Harsh
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2021, 13
  • [23] Evaluation of blebs after glaucoma filtering surgery with en face anterior segment optical coherence tomography
    Meziani, Lyes
    Hassani, Rachid Tahiri Joutei
    El Sanharawi, Mohamed
    Brasnu, Emmanuelle
    Liang, Hong
    Baudouin, Christophe
    Labbe, Antoine
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [24] Changes of the Anterior Eye Segment after Eye Muscle Surgery - Evaluation by Optical Coherence Tomography in Adults
    Luechtenberg, M.
    Haeussler-Sinangin, Y.
    Kohnen, T.
    Kuhli-Hattenbach, C.
    Koss, M. J.
    Schalnus, R.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (10) : 782 - 785
  • [25] Changes of the Anterior Eye Segment after Eye Muscle Surgery - Evaluation by Optical Coherence Tomography in Children
    Haeussler-Sinangin, Y.
    Muller, L.
    Schalnus, R.
    Kohnen, T.
    Luechtenberg, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (09) : 747 - 751
  • [26] Evaluation of changes of anterior segment parameters in patients with pseudoexfoliation syndrome after cataract surgery using anterior segment optical coherence tomography
    Wlaz, Aleksandra
    Kustra, Agnieszka
    Aung, Tin
    Zarnowski, Tomasz
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [27] Evaluation of graft-host interface after penetrating keratoplasty using anterior segment optical coherence tomography
    Sung, Mi Sun
    Yoon, Kyung Chul
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (03) : 282 - 289
  • [28] Anterior segment optical coherence tomography in conjunctival ocular surface disorders - A review
    Rajagopal, Rama
    Vijayaraghavan, Mridula
    Balaji, Janarthanam Jothi
    Jayavel, Karthick
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (04) : 543 - 552
  • [29] Prospective Study: Utility of Anterior Segment Optical Coherence Tomography to Identify Predictive Factors of Recurrence in Pterygium Surgery
    Aguilar-Gonzalez, Marina
    Espana-Gregori, Enrique
    Pascual-Camps, Isabel
    Gomez-Lechon-Quiros, Luis
    Peris-Martinez, Cristina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [30] Comparison of Pericardial Patch Graft Thickness for Glaucoma Implant, Using Anterior Segment Optical Coherence Tomography
    Kang, Min Gu
    Suh, Jae Shin
    Lee, Youn Gon
    Hwang, Young Hoon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (05): : 532 - 537