Evaluation of Conjunctival Graft Thickness after Pterygium Surgery by Anterior Segment Optical Coherence Tomography

被引:26
|
作者
Kheirkhah, Ahmad [1 ]
Adelpour, Mohsen [1 ]
Nikdel, Mojgan [1 ]
Ghaffari, Reza [1 ]
Ghassemi, Hamed [1 ]
Hashemi, Hassan [1 ]
机构
[1] Univ Tehran Med Sci, Farabi Eye Hosp, Eye Res Ctr, Tehran, Iran
关键词
Anterior segment optical coherence tomography; Conjunctival graft; Conjunctival thickness; Pterygium; VIVO CONFOCAL MICROSCOPY; FIBRIN GLUE; AUTOGRAFT; TRANSPLANTATION; TRABECULECTOMY; LIMBAL;
D O I
10.3109/02713683.2011.587937
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To evaluate changes in thickness of the conjunctival graft after pterygium surgery by anterior segment optical coherence tomography (AS-OCT). Materials and Methods: Eleven eyes of 11 patients with primary nasal pterygium underwent excision followed by free conjunctival autograft. Imaging with AS-OCT was performed at 1 week, 1 month and 3 months after surgery to measure thickness of the conjunctival graft at 1, 2 and 3 mm posterior to the scleral spur. As the control, thickness of the normal bulbar conjunctival epithelium in the temporal area was also measured at the same locations. Results: Average thickness of the graft decreased from 458 +/- 171 mu m at 1 week after surgery to 306 +/- 64 mu m at 1 month (p < 0.0001). Although the graft thickness decreased to 291 +/- 124 mu m at 3 months postoperatively, the difference between 1-month and 3-month values was not statistically significant (p = 0.94). Average thickness of the normal conjunctival epithelium was 58 +/- 13 mu m, 60 +/- 19 mu m and 61 +/- 12 mu m at 1 week, 1 month and 3 months after surgery, respectively, with no statistically significant difference. Graft thickness was significantly greater than thickness of the normal conjunctival epithelium at various time points (p < 0.05). Conclusion: Evaluation by AS-OCT showed that there was significant thickening of the conjunctival graft at 1 week after pterygium surgery which continued to decrease up to 3 months. Quantitative data by AS-OCT allows accurate evaluation of the conjunctival changes over time.
引用
收藏
页码:782 / 786
页数:5
相关论文
共 50 条
  • [1] Comparison of conjunctival graft thickness after primary and recurrent pterygium surgery: Anterior segment optical coherence tomography study
    Ozgurhan, Engin Bilge
    Kara, Necip
    Bozkurt, Ercument
    Gencer, Baran
    Yuksel, Kemal
    Demirok, Ahmet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (06) : 675 - 679
  • [2] Changes in conjunctival–scleral thickness after strabismus surgery measured with anterior segment optical coherence tomography
    Hiroko Suzuki
    Akiko Hikoya
    Miwa Komori
    Risako Inagaki
    Takashi Haseoka
    Shinji Arai
    Yuri Takagi
    Yoshihiro Hotta
    Miho Sato
    Japanese Journal of Ophthalmology, 2018, 62 : 554 - 559
  • [3] The role of anterior segment optical coherence tomography in the evaluation of the pterygium
    Batur, Muhammed
    Seven, Erbil
    Tekin, Serek
    Ozer, Muhammet Derda
    Demir, Mehmet Sirac
    Yasar, Tekin
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 43
  • [4] Evaluation of risk factors for recurrence by anterior segment optical coherence tomography in pterygium surgery
    Gonzalez, Marina Aguilar
    Peris-Martinez, Cristina
    Camps, Isabel Pascual
    Ontiveros, Ana Hervas
    Paya, Emma Marin
    Gregori, Enrique Espana
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [5] Changes in conjunctival-scleral thickness after strabismus surgery measured with anterior segment optical coherence tomography
    Suzuki, Hiroko
    Hikoya, Akiko
    Komori, Miwa
    Inagaki, Risako
    Haseoka, Takashi
    Arai, Shinji
    Takagi, Yuri
    Hotta, Yoshihiro
    Sato, Miho
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (05) : 554 - 559
  • [6] Anterior Segment Optical Coherence Tomography Imaging of Conjunctival Filtering Blebs after Glaucoma Surgery
    Mastropasqua, Rodolfo
    Fasanella, Vincenzo
    Agnifili, Luca
    Curcio, Claudia
    Ciancaglini, Marco
    Mastropasqua, Leonardo
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [7] Anterior Segment Optical Coherence Tomography of Conjunctival Nevus
    Shields, Carol L.
    Belinsky, Irina
    Romanelli-Gobbi, Massi
    Guzman, Juan Mica
    Mazzuca, Douglas, Jr.
    Green, W. Ross
    Bianciotto, Carlos
    Shields, Jerry A.
    OPHTHALMOLOGY, 2011, 118 (05) : 915 - 919
  • [8] Prediction of corneal curvature radius after pterygium surgery using anterior segment optical coherence tomography
    Shinya Takahashi
    Shinichi Manabe
    Natsuki Ota
    Ken Hayashi
    Japanese Journal of Ophthalmology, 2019, 63 : 145 - 150
  • [9] Prediction of corneal curvature radius after pterygium surgery using anterior segment optical coherence tomography
    Takahashi, Shinya
    Manabe, Shinichi
    Ota, Natsuki
    Hayashi, Ken
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2019, 63 (02) : 145 - 150
  • [10] Characteristics of conjunctival myxomas on anterior segment optical coherence tomography
    Feng, Paula W.
    Herskowitz, William R.
    Tang, Vincent
    Abou Khzam, Rayan
    Dubovy, Sander R.
    Galor, Anat
    Karp, Carol L.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2024, 59 (06): : e865 - e871