A norepinephrine biosensor based on a glassy carbon electrode modified with carbon nanotubes

被引:18
|
作者
Mohammadi, Ali [2 ,3 ]
Moghaddam, Abdolmajid Bayandori [1 ,4 ]
Hosseini, Samanesadat [4 ]
Kazemzad, Mahmood [5 ]
Dinarvand, Rassoul [6 ]
机构
[1] Univ Tehran, Coll Engn, Dept Engn Sci, Tehran, Iran
[2] Univ Tehran Med Sci, Fac Pharm, Dept Drug & Food Control, Tehran, Iran
[3] Univ Tehran Med Sci, Fac Pharm, Pharmaceut Qual Assurance Res Ctr, Tehran, Iran
[4] Univ Tehran, Nanosci & Nanotechnol Res Ctr, Tehran, Iran
[5] Mat & Energy Res Ctr, Dept Energy, Tehran, Iran
[6] Univ Tehran Med Sci, Fac Pharm, Nanotechnol Res Ctr, Tehran, Iran
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; URINARY CATECHOLAMINES; FLUORESCENCE DETECTION; ASCORBIC-ACID; URIC-ACID; EPINEPHRINE; TYROSINASE; DRUGS; PLANT;
D O I
10.1039/c1ay05291h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immobilized enzyme tyrosinase on single-walled carbon nanotubes (SWCNTs) was used to measure the norepinephrine concentration in injections. A simple method was investigated to prepare a modified glassy carbon (GC) electrode with CNTs. First, CNT solution was cast on the electrode surface and dried to form a CNT/GC electrode. Then, tyrosinase (TR) immobilized on the surface of the CNT/GC electrode. The cyclic voltammograms (CVs) in aqueous solution indicated that the CNTs could promote the direct electron transfer of tyrosinase and a pair of stable redox couple appeared. Tyrosinase can catalyze the oxidation of norepinephrine to norepinephrine quinone. When norepinephrine was added to the electrochemical cell, the oxidation peak current of the TR/SWCNT/GC electrode increased and gives a catalytic current. Based on this, a biosensor for determination of norepinephrine has been developed. This method had adequate accuracy, sensitivity and precision; in addition, the biosensor showed good repeatability and stability to assay norepinephrine in bulk form and pharmaceutical dosage forms.
引用
收藏
页码:2406 / 2411
页数:6
相关论文
共 50 条
  • [21] Amperometric biosensor for bisphenol A based on a glassy carbon electrode modified with a nanocomposite made from polylysine, single walled carbon nanotubes and tyrosinase
    Han, Miao
    Qu, Ying
    Chen, Shiqin
    Wang, Yali
    Zhang, Zhi
    Ma, Ming
    Wang, Zhengguo
    Zhan, Guoqing
    Li, Chunya
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 989 - 996
  • [22] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes (vol 9, e95030, 2014)
    Tang, W.
    Li, L.
    Wu, L.
    Gong, J.
    Zeng, X.
    PLOS ONE, 2015, 10 (03):
  • [23] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes-Chitosan for the Determination of Beef Freshness
    Uwimbabazi, Eric
    Mukasekuru, Marie Rose
    Sun, Xiulan
    FOOD ANALYTICAL METHODS, 2017, 10 (08) : 2667 - 2676
  • [24] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [25] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Multi-Walled Carbon Nanotubes-Chitosan for the Determination of Beef Freshness
    Eric Uwimbabazi
    Marie Rose Mukasekuru
    Xiulan Sun
    Food Analytical Methods, 2017, 10 : 2667 - 2676
  • [26] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Leniart, Andrzej
    Brycht, Mariola
    Burnat, Barbara
    Skrzypek, Sawomira
    IONICS, 2018, 24 (07) : 2111 - 2121
  • [27] An application of a glassy carbon electrode and a glassy carbon electrode modified with multi-walled carbon nanotubes in electroanalytical determination of oxycarboxin
    Andrzej Leniart
    Mariola Brycht
    Barbara Burnat
    Sławomira Skrzypek
    Ionics, 2018, 24 : 2111 - 2121
  • [28] Electrochemical Biosensor of Glucose Based on the Immobilization of Glucose Oxidase on a Carbon Microsphere Modified Glassy Carbon Electrode
    Dong, Yong Ping
    Huang, Li
    Lei, Zhi Ping
    Chu, Xiang Feng
    Zhang, Qian Feng
    SENSOR LETTERS, 2012, 10 (3-4) : 1024 - 1030
  • [29] Amperometric biosensor based on glassy carbon electrode modified with long-length carbon nanotube and enzyme
    Furutaka, Hajime
    Nemoto, Kentaro
    Inoue, Yuki
    Hidaka, Hiroki
    Muguruma, Hitoshi
    Inoue, Hitoshi
    Ohsawa, Tatsuya
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (05)
  • [30] Amperometric choline biosensor based on multiwalled carbon nanotubes/zirconium oxide nanoparticles electrodeposited on glassy carbon electrode
    Pundir, S.
    Chauhan, N.
    Narang, J.
    Pundir, C. S.
    ANALYTICAL BIOCHEMISTRY, 2012, 427 (01) : 26 - 32